Search results for "scanning"
showing 10 items of 1808 documents
A facile method to determine pore size distribution in porous scaffold by using image processing
2015
Abstract Image processing permits scientists to investigate morphological properties of three-dimensional structures starting from their bi-dimensional gray-scale representation. In many cases porous structure with complex architecture has to be designed in order to attempt specific properties such in the case of scaffold for tissue engineering. Traditional morphological characterization, like scanning electron microscopy, should be coupled with quantitative information such as pore size distribution (PSD) in order to get a deeper understanding of the influence of the porous structure on tissue regeneration processes and on other related applications, it is remarkable to study a quantitativ…
Photocrosslinkable polyaspartamide/polylactide copolymer and its porous scaffolds for chondrocytes
2017
With the aim to produce, by a simple and reproducible technique, porous scaffolds potentially employable for tissue engineering purposes, in this work, we have synthesized a methacrylate (MA) copolymer of α,β-poly(N-2-hydroxyethyl)-dl-aspartamide (PHEA) and polylactic acid (PLA). PHEA-PLA-MA has been dissolved in organic solvent at different concentrations in the presence of NaCl particles with different granulometry, and through UV irradiation and further salt leaching technique, various porous scaffolds have been prepared. Obtained samples have been characterized by scanning electron microscopy and their porosity has been evaluated as well as their degradation profile in aqueous medium in…
Preparation and characterization of a biologic scaffold from esophageal mucosa
2013
Biologic scaffolds composed of extracellular matrix (ECM) are commonly used to facilitate a constructive remodeling response in several types of tissue, including the esophagus. Surgical manipulation of the esophagus is often complicated by stricture, but preclinical and clinical studies have shown that the use of an ECM scaffold can mitigate stricture and promote a constructive outcome after resection of full circumference esophageal mucosa. Recognizing the potential benefits of ECM derived from homologous tissue (i.e., site-specific ECM), the objective of the present study was to prepare, characterize, and assess the in-vivo remodeling properties of ECM from porcine esophageal mucosa. The…
Fine-tuning scaffolds for tissue regeneration: effects of formic acid processing on tissue reaction to silk fibroin
2010
Formic acid (FA) plays a key role in the preparation of silk fibroin (SF) scaffolds from cocoons of Bombyx mori and is used for fibre distribution. In this study, we used a subcutaneous implantation model in Wistar rats to examine SF scaffolds prepared by treating the degummed cocoon with FA for either 30 or 60 min. The tissue reaction and inflammatory response to SF was assessed by qualitative histology at intervals from 3 to 180 days. Additionally, dynamic biomaterial-induced vascularization and biomaterial degradation were quantified using a technique for analysing an image of the entire implanted biomaterial. Varying the FA treatment time led to different scaffold morphologies and resul…
Morphostructural analysis of human follicular stem cells on highly porous bone hydroxyapatite scaffold
2007
In this study we investigated the in vitro behaviour, morphostructure and extracellular matrix synthesis of human dental follicular stem cells (hDFSCs) isolated from human dental bud, which resulted to be positive for mesenchymal markers (CD29, CD90, CD146 and CD166) by FACS analysis. Cells were analysed by light and electronic microscopy to evaluate their biological response either at week 1, that is before differentiation, or at weeks 3–6, when they had been cultured in osteogenic medium onto a highly porous natural scaffold material (Bio-Oss®). Microscopy analysis of primary culture cells showed they had a mesenchymal stem cell-like morphostructure, spindle shaped, similar to the cultur…
Reflection scanning microscopy.
1992
To image nontransparent samples we have utilized a special type of scanning-probe microscope that is referred to here as a reflection scanning microscope. The reflection scanning microscope provides a method for producing a scanned point light source as well as a system for collecting the light that is reflected by the sample. The system, which uses an optical fiber coupler, is easily installed on an existing photon scanning tunneling microscope. A calculation of the coupling coefficient between the natural propagation mode of the optical fiber and the light that is reflected by the sample is presented along with a comparison between calculated and measured values of the intensity of the li…
Imaging of surface plasmon propagation and edge interaction using a photon scanning tunneling microscope
1994
We report the direct imaging of surface plasmon propagation on thin silver films using the photon scanning tunneling microscope. It is found that the surface plasmon remains tightly confined in the original launch direction with insignificant scattering to other momentum states. A propagation length of 13.2 \ensuremath{\mu}m is measured at \ensuremath{\lambda}=632.8 nm. We also present images showing the interaction of a surface plasmon with the edge of the metal film supporting it. The most remarkable feature is the absence of specularly reflected beam.
Magnetic Domain Imaging with a Photoemission Microscope
1997
ABSTRACTPhotoelectron emission microscopy (PEEM) has proven to be a versatile analytical technique in surface science. When operated with circularly polarized light in the soft x-ray regime, however, photoemission microscopy offers a unique combination of magnetic and chemical information. Exploiting the high brilliance and circular polarization available at a helical undulator beamline, the lateral resolution in the imaging of magnetic domain structures may be pushed well into the sub-micrometer range. Using a newly designed photoemission microscope we show that under these circumstances not only domains, but also domain walls can be selectively investigated. The high sensitivity of the te…
A computer controlled patterning system for scanning probe microscopes
1999
Abstract A pattern generator system for lithography based on scanning force microscopes has been developed. Patterns to be miniaturized onto a chip can be scanned or drawn by any common graphical program. The pattern file is used to control a voltage simultaneously with the microscope probe scanning the surface of the substrate. The voltage can be used in numerous different ways to manipulate the substrate, depending on the lithographic method preferred. We have demonstrated the system by adding this voltage to the z -piezo voltage of the scanner, in order to make the probe plow the pattern into a film spinned on the sample. To maintain linearity in zooming in and rotating the scanning dire…
Enhanced photocatalytic performance of novel electrospun BN/TiO 2 composite nanofibers
2017
International audience; High activity boron nitride/titanium dioxide (BN/TiO2) composite nanofiber photocatalysts were synthesized for the first time via the electrospinning technique. The as-spun nanofibers with a controlled ratio of boron nitride nanosheets (BN) were calcined under air at 500 °C for 4 hours. Their morphological, structural and optical properties were studied by scanning electron microscopy (SEM), X-ray diffraction (XRD), energy-dispersive X-ray spectroscopy (EDX), BET surface area, Fourier-transform infrared (FTIR), Raman spectroscopy, UV-Visible spectrophotometry and room temperature photoluminescence (PL). The effect of loading different BN sheet amounts on the photocat…