Search results for "scanning"
showing 10 items of 1808 documents
Efficacy of NaOCl/H2O2irrigation and GaAlAs laser in decontamination of root canals in vitro
2003
Background and Objectives To investigate the bactericidal effect of an 809 nm semiconductor laser alone, and in combination with NaOCl/H2O2 irrigation in root canals in vitro. Study Design/Materials and Methods A total of 72 human single-rooted teeth extracted for periodontal reasons were included. The crowns were removed, the roots shortened to a length of 12 mm, and the canals enlarged up to an apical size of #50 file. The specimens were autoclaved and incubated with a suspension of Streptococcus sanguinis (ATCC 10556). Laser irradiation was performed on a PC-controlled XY translation stage. A 200 micron optic fiber was used. Twelve specimens were irradiated at a power output of 1.5, 3.0,…
WITHDRAWN: Defining In Vivo Mucosal Inflammatory Activity Using Laser Scanning Confocal Endomicroscopy in Human Ulcerative Colitis
2008
This article has been withdrawn consistent with Elsevier Policy on Article Withdrawal (http://www.elsevier.com/locate/withdrawalpolicy). The Publisher apologizes for any inconvenience this may cause.
Prognostic value of cardiac CT
2020
In the past decades, coronary computed tomography angiography (CCTA) has become a powerful tool in the management of coronary artery disease. The diagnostic and prognostic value of CCTA has been extensively demonstrated in both large observational studies and clinical trials among stable chest pain patients. The quantification of coronary artery calcium score (CACS) is a well-established predictor of cardiovascular morbidity and mortality in asymptomatic subjects. Besides CACS, the main strength of CCTA is the accurate assessment of the individual total atherosclerotic plaque burden, which holds important prognostic information. In addition, CCTA, by providing detailed information on corona…
Quantitative magnetic resonance imaging for focal liver lesions: bridging the gap between research and clinical practice
2021
Magnetic resonance imaging (MRI) is highly important for the detection, characterization, and follow-up of focal liver lesions. Several quantitative MRI-based methods have been proposed in addition to qualitative imaging interpretation to improve the diagnostic work-up and prognostics in patients with focal liver lesions. This includes DWI with apparent diffusion coefficient measurements, intravoxel incoherent motion, perfusion imaging, MR elastography, and radiomics. Multiple research studies have reported promising results with quantitative MRI methods in various clinical settings. Nevertheless, applications in everyday clinical practice are limited. This review describes the basic princ…
Vasodilator Stress CMR and All-Cause Mortality in Stable Ischemic Heart Disease
2020
Abstract Objectives This study explored the association of ischemic burden, as measured by vasodilator stress cardiovascular magnetic resonance (CMR), with all-cause mortality and the effect of revascularization on all-cause mortality in patients with stable ischemic heart disease (SIHD). Background In patients with SIHD, the association of ischemic burden, derived from vasodilator stress CMR, with all-cause mortality and its role for decision-making is unclear. Methods The registry consisted of 6,389 consecutive patients (mean age: 65 ± 12 years; 38% women) who underwent vasodilator stress CMR for known or suspected SIHD. The ischemic burden (at stress first-pass perfusion imaging) was com…
Study of Post-Infarction Coronary Perfusion Using Quantitative Analysis of Myocardial Echocardiography With Intravenous Injection of Contrast
2005
Introduction and objectives. After a myocardial infarction, damage to the microcirculation indicates a worse prognosis. We compared the usefulness of the quantitative analysis of myocardial contrast echocardiography with intravenous injection of contrast (MCE-iv) with intracoronary injection (MCE-ic) for analyzing coronary perfusion. Patients and method. We studied 42 patients with a first ST-elevation myocardial infarction, single-vessel disease and a patent artery (TIMI 3, stenosis 0.75) and MCE-iv (perfusion of SonoVue, singleimage capture in 1 out of each 6 cycles with trigger set at end-systole, perfusion considered normal if >0.9). Perfusion was considered abnormal if 2 or more segmen…
Intraosseous gas distribution as a marker of postmortem interval
2020
Abstract The postmortem interval is probably the most important puzzle piece in clarifying the circumstances in case of death occurred in unknown conditions. Over the years, radio-imaging modalities have proved their worth in forensic field, providing additional and significant improvements and findings. CT-scan is characterized by wide availability, fast scan times and sustainable healthcare costs. Detection of gas, hemorrhage and bone fractures are points of strength of CT-scan. A reliable evaluation of the post-mortem interval is interesting in the victims of a mass disaster, also following a natural disaster, for the individuation of responsibility in the efficiency of the help and assi…
Implementation of computed tomography angiography (CTA) and computed tomography perfusion (CTP) in Polish guidelines for determination of cerebral ci…
2021
Background: Brain death/death by neurologic criteria (BD/DNC) guidelines are routinely analyzed, compared and updated in the majority of countries and are later implemented as national criteria. At the same time, extensive works have been conducted in order to unify clinical procedures and to validate and implement new technologies into a panel of ancillary tests. Recently evaluated computed tomography angiography and computed tomography perfusion (CTA/CTP) seem to be superior to traditionally used digital subtraction angiography (DSA), transcranial Doppler (TCD) and cerebral perfusion scintigraphy for diagnosis of cerebral circulatory arrest (CCA). In this narrative review, we would like t…
Does Posterior Capsule Opacification Affect the Results of Diagnostic Technologies to Evaluate the Retina and the Optic Disc?
2014
The visual outcome obtained after cataract removal may progressively decline because of posterior capsular opacification (PCO). This condition can be treated by creating an opening in the posterior lens capsule by Nd:YAG laser capsulotomy. PCO optical imperfections cause several light reflection, refraction, and diffraction phenomena, which may interfere with the functional and structural tests performed in different ocular locations for the diagnosis and follow-up of ocular disease, like macular and optic nerve diseases. Some parameters measured by visual field examinations, scanning laser polarimetry, and optical coherence tomography (OCT) have changed after PCO removal. Imaging quality a…
PET Lung Ventilation/Perfusion Imaging Using 68Ga Aerosol (Galligas) and 68Ga-Labeled Macroaggregated Albumin
2012
Pulmonary imaging using ventilation/perfusion (V/P) single-photon emission tomography (V/P scan) with Tc-99m-labeled radiotracers is a well-established diagnostic tool for clinically suspected pulmonary embolism (PE). Ga-68 aerosol (Galligas) and Ga-68-labeled macroaggregated albumin (MAA) are potential tracers for positron emission tomography (PET) lung V/P imaging and could display an advantage over conventional V/P scans in terms of sensitivity and specificity. After radiochemical and animal studies, the clinical applicability of Ga-68 aerosol (Galligas) and Ga-68-labeled MAA was investigated in an exploratory study in patients with clinical suspicion of PE. PET scans were acquired using…