Search results for "semiconductor detector"
showing 10 items of 108 documents
Searches for neutrinoless resonant double electron captures at LNGS
2012
Several experiments were performed during last years at underground (3600 m w.e.) Laboratori Nazionali del Gran Sasso (LNGS) of the INFN (Italy) to search for resonant 2$\varepsilon0\nu$ captures in 96Ru, 106Cd, 136Ce, 156Dy, 158Dy, 180W, 184Os, 190Pt with the help of HP Ge semiconductor detectors, and ZnWO4 and 106CdWO4 crystal scintillators. No evidence for r-2$\varepsilon0\nu$ decays was found, and only T_{1/2} limits were established in the range of 10^{14}-10^{21} yr.
Identification of sub- μs isomeric states in the odd-odd nucleus Au178
2021
The neutron-deficient gold (Z=79) isotopes in the vicinity of the neutron midshell N=104 provide prolific examples of shape coexistence and isomerism at low excitation energy. They can be probed via a number of different experimental techniques. In this study, two new isomeric states with half-lives of 294(7) and 373(9) ns have been observed in the neutron-deficient odd-odd nuclide Au178 (N=99) in an experiment at the RITU gas-filled separator at JYFL, Jyvaskyla. This result was achieved due to the use of a segmented planar germanium detector with a high efficiency at low energies. By applying the recoil-decay tagging technique, they were assigned to decay to two different long-lived α-deca…
Super-Allowed β Decay of23Mg Studied with a High-Precision Germanium Detector
2015
A neural network clustering algorithm for the ATLAS silicon pixel detector
2014
A novel technique to identify and split clusters created by multiple charged particles in the ATLAS pixel detector using a set of artificial neural networks is presented. Such merged clusters are a common feature of tracks originating from highly energetic objects, such as jets. Neural networks are trained using Monte Carlo samples produced with a detailed detector simulation. This technique replaces the former clustering approach based on a connected component analysis and charge interpolation. The performance of the neural network splitting technique is quantified using data from proton-proton collisions at the LHC collected by the ATLAS detector in 2011 and from Monte Carlo simulations. …
Data quality monitors of vertex detectors at the start of the Belle II experiment
2019
The Belle II experiment features a substantial upgrade of the Belle detector and will operate at the SuperKEKB energy-asymmetric e+e− collider at KEK in Tsukuba, Japan. The accelerator completed its first phase of commissioning in 2016, and the Belle II detector saw its first electron-positron collisions in April 2018. Belle II features a newly designed silicon vertex detector based on double-sided strip layers and DEPFET pixel layers. A subset of the vertex detector was operated in 2018 to determine background conditions (Phase 2 operation). The collaboration completed full detector installation in January 2019, and the experiment started full data taking. This paper will report on the fin…
A low-level spectrometer with a planar low-energy HPGe: shielding arrangement tests and system performance for 210Pb determination in air filter samp…
2001
A system for low-energy photon spectrometry using a planar germanium detector with appropriate specifications is presented. A spectrometric background investigation has been carried out with various detector shielding arrangements. The characteristics of the system for measurements of 210Pb in air-particulate matter on filters have been determined.
Design and test of a prototype silicon detector module for ATLAS Semiconductor Tracker endcaps
2005
The ATLAS Semiconductor Tracker (SCT) will be a central part of the tracking system of the ATLAS experiment. The SCT consists of four concentric barrels of silicon detectors as well as two silicon endcap detectors formed by nine disks each. The layout of the forward silicon detector module presented in this paper is based on the approved layout of the silicon detectors of the SCT, their geometry and arrangement in disks, but uses otherwise components identical to the barrel modules of the SCT. The module layout is optimized for excellent thermal management and electrical performance, while keeping the assembly simple and adequate for a large scale module production. This paper summarizes th…
Determination of macro, micro nutrient and trace element concentrations in Indian medicinal and vegetable leaves using instrumental neutron activatio…
1999
Abstract Leafy samples often used as medicine in the Indian Ayurvedic system and vegetables were analyzed for 20 elements (As, Ba, Br, Ca, Ce, Cr, Cs, Co, Eu, Fe, K, La, Na, Rb, Sb, Sc, Sm, Sr, Th, Zn) by employing Instrumental Neutron Activation Analysis (INAA). The samples were irradiated at the 100 kW TRIGA-MAINZ nuclear reactor and the induced activities were counted by gamma ray spectrometry using an efficiency calibrated high resolution High Purity Germanium (HPGe) detector. The concentration of the elements in the medicinal and vegetable leaves and their biological effects on human beings are discussed.
An experimental approach to efficiency calibration for gamma-ray spectrometric analysis of large air particulate filters
2013
Abstract A full-energy-peak efficiency (FEPE) calibration procedure for gamma-ray spectrometric analysis of air particulate samples collected on large filters is described herein. The experimental results are obtained for an unconventional measurement geometry, termed a “packet-sample”. The sample is obtained from a large cellulose filter (45 cm×45 cm) used to collect air particulate samples that is resized to dimensions suitable for spectrometric measurements (6 cm×6 cm×0.7 cm). To determine the FEPEs, many standards were created, i.e., some filters containing a small amount of ThO 2 and others containing a known amount of KCl. Efficiency curves obtained through best fits to experimental d…
The Miniball spectrometer
2013
The Miniball germanium detector array has been operational at the REX (Radioactive ion beam EXperiment) post accelerator at the Isotope Separator On-Line facility ISOLDE at CERN since 2001. During the last decade, a series of successful Coulomb excitation and transfer reaction studies have been performed with this array, utilizing the unique and high-quality radioactive ion beams which are available at ISOLDE. In this article, an overview is given of the technical details of the full Miniball setup, including a description of the γ-ray and particle detectors, beam monitoring devices and methods to deal with beam contamination. The specific timing properties of the REX-ISOLDE facility are hi…