Search results for "sensitivity and specificity"
showing 10 items of 1080 documents
Single tube real time PCR for detection of Streptococcus pneumoniae, Mycoplasma pneumoniae, Chlamydophila pneumoniae and Legionella pneumophila from …
2012
We designed a multiplex real time PCR for rapid, sensitive and specific detection of Streptococcus pneumoniae, Legionella pneumophila, Chlamydophila pneumoniae and Mycoplasma pneumoniae. The study cases consisted of 129 patients with community acquired pneumonia (CAP). Bacteriological techniques were implemented for detection of the cultivable organisms. DNA were extracted from sputa, throat swabs, bronchoalveolar lavages and tracheal aspirates and used as templates in real time PCR. The primers and probes were designed for cbpA (S. pneumoniae), p1adhesin (M. pneumoniae), mip (L. pneumophila) and ompA (C. pneumoniae). After optimization of real time PCR for every organism, the experiments w…
Automatic differentiation of melanoma from dysplastic nevi.
2015
International audience; Malignant melanoma causes the majority of deaths related to skin cancer. Nevertheless, it is the most treatable one, depending on its early diagnosis. The early prognosis is a challenging task for both clinicians and dermatologist, due to the characteristic similarities of melanoma with other skin lesions such as dysplastic nevi. In the past decades, several computerized lesion analysis algorithms have been proposed by the research community for detection of melanoma. These algorithms mostly focus on differentiating melanoma from benign lesions and few have considered the case of melanoma against dysplastic nevi. In this paper, we consider the most challenging task a…
An Instrument-Assisted coracoid pain test: an exploratory diagnostic accuracy study
2022
The coracoid pain test (CPT) could contribute to the diagnosis of frozen shoulder (FS) with palpation. However, due to assessor performance these values might be unreliable. Therefore, the aim was to explore the diagnostic accuracy of an instrument-assisted CPT and two alternative approaches (pain severity and side comparison) for assistance in the diagnosis of FS. Patients with FS and healthy age-matched controls were recruited. All participants underwent the instrument-assisted CPT on both shoulders with a pressure algometer. Sensitivity, specificity, and likelihood ratios were determined for the three approaches. In total, 35 patients with FS and 35 healthy participants were included. Th…
A method for quantifying atrial fibrillation organization based on wave-morphology similarity
2002
A new method for quantifying the organization of single bipolar electrograms recorded in the human atria during atrial fibrillation (AF) is presented. The algorithm relies on the comparison between pairs of local activation waves (LAWs) to estimate their morphological similarity, and returns a regularity index (/spl rho/) which measures the extent of repetitiveness over time of the detected activations. The database consisted of endocardial data from a multipolar basket catheter during AF and intraatrial recordings during atrial flutter. The index showed maximum regularity (/spl rho/=1) for all atrial flutter episodes and decreased significantly when increasing AF complexity as defined by W…
An Automatic System for the Analysis and Classification of Human Atrial Fibrillation Patterns from Intracardiac Electrograms
2008
This paper presents an automatic system for the analysis and classification of atrial fibrillation (AF) patterns from bipolar intracardiac signals. The system is made up of: 1) a feature- extraction module that defines and extracts a set of measures potentially useful for characterizing AF types on the basis of their degree of organization; 2) a feature-selection module (based on the Jeffries-Matusita distance and a branch and bound search algorithm) identifying the best subset of features for discriminating different AF types; and 3) a support vector machine technique-based classification module that automatically discriminates the AF types according to the Wells' criteria. The automatic s…
P300-based brain computer interface experimental setup
2009
A Brain-Computer interface (BCI) is a communication system that enables the generation of a control signal from brain signals such as sensorymotor rhythms and evoked potentials; therefore, it constitutes a novel communication option for people with severe motor disabilities (such as Amyotrophic Lateral Sclerosis patients). This paper presents the development of a P300-based BCI. This prototype uses a homemade six-channel electroencephalograph for the acquisition of the signals, and a visual stimulation matrix; since this matrix contains letters of the alphabet as well as images associated to them, it permits word-writing and the elaboration of messages with the images. To process the signal…
Quantification of synchronization during atrial fibrillation by Shannon entropy: Validation in patients and computer model of atrial arrhythmias
2005
Atrial fibrillation (AF), a cardiac arrhythmia classically described as completely desynchronized, is now known to show a certain amount of synchronized electrical activity. In the present work a new method for quantifying the level of synchronization of the electrical activity recorded in pairs of atrial sites during atrial fibrillation is presented. A synchronization index (Sy) was defined by quantifying the degree of complexity of the distribution of the time delays between sites by Shannon entropy estimation. The capability of Sy to discriminate different AF types in patients was assessed on a database of 60 pairs of endocardial recordings from a multipolar basket catheter. The analysis…
Timing performance of the silicon PET insert probe
2010
Simulation indicates that PET image could be improved by upgrading a conventional ring with a probe placed close to the imaged object. In this paper, timing issues related to a PET probe using high-resistivity silicon as a detector material are addressed. The final probe will consist of several (four to eight) 1-mm thick layers of silicon detectors, segmented into 1 x 1 mm(2) pads, each pad equivalent to an independent p + nn+ diode. A proper matching of events in silicon with events of the external ring can be achieved with a good timing resolution. To estimate the timing performance, measurements were performed on a simplified model probe, consisting of a single 1-mm thick detector with 2…
Dosimetry comparison between TG-43 and Monte Carlo calculations using the Freiburg flap for skin high-dose-rate brachytherapy
2012
Abstract Purpose The purpose of this work was to evaluate whether the delivered dose to the skin surface and at the prescription depth when using a Freiburg flap applicator is in agreement with the one predicted by the treatment planning system (TPS) using the TG-43 dose-calculation formalism. Methods and Materials Monte Carlo (MC) simulations and radiochromic film measurements have been performed to obtain dose distributions with the source located at the center of one of the spheres and between two spheres. Primary and scatter dose contributions were evaluated to understand the role played by the scatter component. A standard treatment plan was generated using MC- and TG-43-based TPS appl…
Genetic parameters for somatic cell score according to udder infection status in Valle del Belice dairy sheep and impact of imperfect diagnosis of in…
2010
Abstract Background Somatic cell score (SCS) has been promoted as a selection criterion to improve mastitis resistance. However, SCS from healthy and infected animals may be considered as separate traits. Moreover, imperfect sensitivity and specificity could influence animals' classification and impact on estimated variance components. This study was aimed at: (1) estimating the heritability of bacteria negative SCS, bacteria positive SCS, and infection status, (2) estimating phenotypic and genetic correlations between bacteria negative and bacteria positive SCS, and the genetic correlation between bacteria negative SCS and infection status, and (3) evaluating the impact of imperfect diagno…