Metrological Properties of the Test Setup for Determination Shielding Effectiveness of the Industrial Cable Connectors
2017
Abstract The paper presents results related to assessment of the repeatability and reproducibility of the measurement test setup for determination the relative value of the shielding effectiveness coefficient of the industrial connectors. The construction of the proposed test setup, the measurement method and the procedure for the analysis of measurement results were described. To determine the value of the repeatability and reproducibility coefficient, the two–way analysis of variance was used, which additionally allows for an assessment of the influence of individual sources of variance. The measurements and their analysis were conducted for several frequencies in the range up to 1 GHz. A…
Antineutrino monitoring of spent nuclear fuel
2016
Military and civilian applications of nuclear energy have left a significant amount of spent nuclear fuel over the past 70 years. Currently, in many countries world wide, the use of nuclear energy is on the rise. Therefore, the management of highly radioactive nuclear waste is a pressing issue. In this letter, we explore antineutrino detectors as a tool for monitoring and safeguarding nuclear waste material. We compute the flux and spectrum of antineutrinos emitted by spent nuclear fuel elements as a function of time, and we illustrate the usefulness of antineutrino detectors in several benchmark scenarios. In particular, we demonstrate how a measurement of the antineutrino flux can help to…
Evaluation of the shielding in a treatment room with an electronic brachytherapy unit.
2017
Esteya® (Elekta Brachytherapy, Veenendaal, The Netherlands) is an electronic brachytherapy (eBT) system based on a 69.5 kVp x-ray source and a set of collimators of 1 to 3 cm in diameter, used for treating non-melanoma skin cancer lesions. This study aims to estimate room shielding requirements for this unit. The non-primary (scattered and leakage) ambient dose equivalent rates were measured with a Berthold LB-133 monitor (Berthold Technologies, Bad Wildbad, Germany). The latter ranges from 17 mSv h-1 at 0.25 m distance from the x-ray source to 0.1 mSv h-1 at 2.5 m. The necessary room shielding was then estimated following US and some European guidelines. The room shielding for all barriers…
Stable radical anions generated from a porous perylenediimide metal-organic framework for boosting near-infrared photothermal conversion
2019
Radical anions of electron-deficient systems are widely used, but are easily reoxidized upon exposure to air. Therefore, the stabilization of radical anions under ambient conditions is of great significance, but still remains a scientific challenge. Herein, perylenediimide is employed to prepare a crystalline metal-organic framework for stabilizing radical anions without extensive chemical modification. The porous, three-dimensional framework of perylenediimide can trap electron donors such as amine vapors and produce radical anions in-situ through photo-induced electron transfer. The radical anions are protected against quenching by shielding effect in air and remain unobstructed in air fo…
Can hip resurfacing be safely revised with short-stem total hip arthroplasty? A case series of six patients.
2021
Abstract Background The usage of short stems in primary total hip arthroplasty (THA) has constantly gained popularity over the last decade, however, to date, short stems are not eligible to be used as revision implants. The aim of this study was to retrospectively evaluate the outcome of revision surgery of failed hip resurfacing arthroplasty (HRA) using short-stem THA. Methods In a single center, retrospective analysis, 6 consecutive patients who were treated with a calcar-guided short stem after failure of HRA were evaluated. The mean follow-up was 3.25 years (SD 0.45). Patient reported outcome measurements (PROMs) were recorded using the Harris hip score (HHS) and The Western Ontario and…
Fetal dose measurements and shielding efficiency assessment in a custom setup of (192)Ir brachytherapy for a pregnant woman with breast cancer.
2015
To assess the radiation dose to the fetus of a pregnant patient undergoing high-dose-rate (HDR) (192)Ir interstitial breast brachytherapy, and to design a new patient setup and lead shielding technique that minimizes the fetal dose.Radiochromic films were placed between the slices of an anthropomorphic phantom modeling the patient. The pregnant woman was seated in a chair with the breast over a table and inside a leaded box. Dose variation as a function of distance from the implant volume as well as dose homogeneity within a representative slice of the fetal position was evaluated without and with shielding.With shielding, the peripheral dose after a complete treatment ranged from 50 cGy at…
Understanding the ring current effects on magnetic shielding of hydrogen and carbon nuclei in naphthalene and anthracene
2008
The local response to an external magnetic field normal to the molecular plane of naphthalene and anthracene was investigated via current density and magnetic shielding density maps. The Biot-Savart law shows that the deshielding caused by pi-ring currents in naphthalene is stronger for alpha- than for beta-protons due to geometrical factors. The shielding tensor of the carbon nuclei in both molecules is strongly anisotropic and its out-of-plane component determines the up-field chemical shift of (13)C in nuclear magnetic resonance spectra. The pi-ring currents flowing beyond the C-skeleton in front of a probe carbon nucleus, and on remote parts of the molecular perimeter, yield positive co…
Estimation of isotropic nuclear magnetic shieldings in the CCSD(T) and MP2 complete basis set limit using affordable correlation calculations
2013
A linear correlation between isotropic nuclear magnetic shielding constants for seven model molecules (CH2O, H2O, HF, F2, HCN, SiH4 and H2S) calculated with 37 methods (34 density functionals, RHF, MP2 and CCSD(T)), with affordable pcS-2 basis set and corresponding complete basis set results, estimated from calculations with the family of polarization-consistent pcS-n basis sets is reported. This dependence was also supported by inspection of profiles of deviation between CBS estimated nuclear shieldings and shieldings obtained with the significantly smaller basis sets pcS-2 and aug-cc-pVTZ-J for the selected set of 37 calculation methods. It was possible to formulate a practical approach o…
Efficient Shielding of Polyplexes Using Heterotelechelic Polysarcosines
2018
Shielding agents are commonly used to shield polyelectrolyte complexes, e.g. polyplexes, from agglomeration, precipitation in complex media, like blood, and thus enhance their circulation times in vivo. Since up to now primarily poly(ethylene glycol) (PEG) has been investigated to shield non-viral carriers for systemic delivery, we report on the use of polysarcosine (pSar) as a potential alternative for steric stabilization. A redox-sensitive, cationizable lipo-oligomer structure (containing two cholanic acids attached via a bioreducible disulfide linker to an oligoaminoamide backbone in T-shape configuration) was equipped with azide-functionality by solid phase supported synthesis. After m…
Orbital Decomposition of the Carbon Chemical Shielding Tensor in Gold(I) N-Heterocyclic Carbene Complexes.
2020
The good performance of N‐heterocyclic carbenes (NHCs), in terms of versatility and selectivity, has called the attention of experimentalists and theoreticians attempting to understand their electronic properties. Analyses of the Au(I)–C bond in [(NHC)AuL]+/0 (L stands for a neutral or negatively charged ligand), through the Dewar–Chatt–Duncanson model and the charge displacement function, have revealed that NHC is not purely a σ‐donor but may have a significant π‐acceptor character. It turns out, however, that only the σ‐donation bonding component strongly correlates with one specific component of the chemical shielding tensor. Here, in extension to earlier works, a current density analysi…