Search results for "silicon photomultiplier"
showing 10 items of 87 documents
Electron beam studies of light collection in a scintillating counter with embedded fibers
2021
The light collection of several fiber configurations embedded in a box-shaped plastic scintillating counter was studied by scanning with minimum ionizing electrons. The light was read out by silicon photomultipliers at both ends. The light yield produced by the 855-MeV beam of the Mainz Microtron showed a strong dependence on the transverse distance from the beam position to the fibers. The observations were modeled by attributing the collection of indirect light inside of the counter and of direct light reaching a fiber to the total light yield. The light collection with fibers was compared to that of a scintillating counter without fibers. These studies were carried out within the develop…
Efficiency studies for a tracking detector based on square 1.5m long scintillating fibers read out by SiPM
2009
Abstract A tracking detector based on 1.5 m long scintillating fibers is being developed for the electron arm of the KAOS spectrometer at the Mainz Microtron MAMI. Measurements on light attenuation, particle detection efficiencies and accidental coincidence rates with a prototype set-up using 2 × 2 mm 2 fibers read out by silicon photomultipliers (SiPM) are presented. The highest efficiency at the lowest accidental coincidence rate was reached for high trigger thresholds at the largest SiPM bias voltages. The influence of signal attenuation and dispersion on detection efficiencies is discussed. The results are in good agreement with a Monte Carlo model that was used to predict detector char…
Time of flight measurements based on FPGA and SiPMs for PET–MR
2014
Coincidence time measurements with SiPMs have shown to be suitable for PET/MR systems. The present study is based on 3 x 3 mm(2) SiPMs, LSO crystals and a conditioning signal electronic circuit. A Constant Fraction Discriminator (CFD) is used to digitalize the signals and a TDC FPGA-implemented is employed for fine time measurements. TDC capability allows processing the arrival of multiple events simultaneously, measuring times under 100 ps. The complete set-up for time measurements results on a resolution of 892 +/- 41 ps for a pair of detectors. The details of such implementation are exposed and the trade-offs of each configuration are discussed. (C) 2013 Elsevier By, All rights reserved,
Detector blockbased on arrays of 144 SiPMs and monolithic scintillators: A performane study
2015
[EN] We have developed a detector block composed by a monolithic LYSO scintillator coupled to a custom made 12 12 SiPMs array. The design is mainly focused to applications such as Positron Emission Tomography. The readout electronics is based on 3 identical and scalable Application Specific Integrated Circuits (ASIC). We have determined the main performance of the detector block namely spatial, energy, and time resolution but also the system capability to determine the photon depth of interaction, for different crystal surface treatments. Intrinsic detector spatial resolution values as good as 1.7 mm FWHM and energies of 15% for black painted crystals were measured. & 2014 Elsevier B.V. All…
Comparison of Silicon Photomultiplier Characteristics using Automated Test Setups
2016
Silicon Photomultipliers (SiPM) are photo-sensors consisting of an array of hundreds to thousands pixels with a typical pitch of 10-100 μm. They exhibit an excellent photon counting and time resolution. Therefore applications of SiPMs are emerging in many fields. In order to characterize SiPMs, the PRISMA Detector Lab at Mainz has established three automated test setups. Setup-A is dedicated to measure the gain, the dark count rate and the optical crosstalk probability. The temperature dependencies are characterized by operating the setup in a climate chamber. Setup-B is an optical system to measure the photon detection efficiency. Setup-C addresses the most challenging aspect of comparing …
Proof-of-principle measurements with a liquid-scintillator detector using wavelength-shifting optical modules
2018
Based on test-beam measurements, we study the response of a liquid-scintillator detector equipped with wavelength-shifting optical modules, that are proposed e.g. for the IceCube experiment and the SHiP experiment, and adiabatic light guides that are viewed either by a photomultiplier tube or by an array of silicon photomultipliers. We report on the efficiency, the time resolution and the detector response to different particle types and point out potential ways to improve the detector performance.
A tracking fiber detector based on silicon photomultipliers for the KAOS spectrometer
2011
A tracking detector based on two meters long scintillating fibers read out by silicon photomultipliers (SiPM) is being developed for the Kaos spectrometer at the Mainz Microtron MAMI. Results from a prototype setup using 2 mm square fibers and large area SiPM readout are presented. The detection efficiency of such a combination was measured to be between 83 and 100% depending on the threshold on the SiPM amplitude. A Monte Carlo simulation based on a physical model was employed in order to extract the photon detection efficiency of the SiPM devices.
SNR measurements of silicon photomultipliers in the continuous wave regime
2014
We report on our Signal-to-Noise Ratio (SNR) measurements carried out, in the continuous wave regime, at different frequencies and at various temperatures, on a novel class of silicon photomultipliers (SiPMs) fabricated in planar technology on silicon p-type substrate. SNR of SiPMs is given by the ratio of the photogenerated current, filtered and averaged by a lock-in amplifier, and the Root Mean Square (RMS) deviation of the same current. In our measurements, we have employed a 10 Hz equivalent noise bandwidth, around the lock-in amplifier reference frequency. The measured noise takes into account the shot noise, resulting from the photocurrent and the dark current, while background light …
First Compton imaging tests with i-TED
2019
The objective of this work is to demonstrate the Compton imaging capabilities of a novel gamma-ray Total-Energy Detector called i-TED. The latter is intended for neutron-capture cross-sections measurements of astrophysical interest, thereby enhancing detection sensitivity by means of the simultaneous combination of Time-of-Flight with Compton-imaging techniques. The developed i-TED demonstrator comprises five position-sensitive radiation detection modules of high energy resolution, which feature an overall position-sensitive field-of-view of 125 cm2, and thus a high efficiency. Each detector module is based on 50x50 mm2 large LaCl 3 (Ce) monolithic crystals optically coupled to 8x8 pixels s…
Silicon photomultiplier properties at cryogenic temperatures
2015
Abstract The properties of different types of silicon photomultipliers (SiPMs) were studied at cryogenic temperatures. In liquid nitrogen at 77 K, problems with quenching in Hamamatsu SiPMs and with the protective epoxy layer, covering Zecotek SiPMs, were observed. Tests with one Zecotek SiPM were successful after removal of the epoxy layer. In liquid helium at 4 K, fast signals with pulse lengths shorter than 50 ns were observed, the dark count rate was below 10 Hz and no after-pulses were detected. The gain, as a function of over-voltage, was comparable to room temperature. The SiPM׳s response to photons was found to be linear with intensity for low light levels and single-photon detectio…