Search results for "silicone"
showing 10 items of 78 documents
Deformation of bubbles in silicon gel insulation under an alternating electric field
2019
The behavior of silicone gel under electrical stress plays a significant role in the reliability and durability of high voltage electronic power devices due to its widespread use for the insulation of IGBT modules and other components. The charges accumulation at the bubble boundaries leads to significant displacements due to the establishment of Coulombic forces and the high deformability of colloidal system. The main purpose of this work is to validate a numerical approach useful to investigate, for a given silicone gel, the non-linear relation between the applied HVDC stress and the electric field over an air bubble within the insulation bulk. The analysis has been carried out by means o…
Porosity analysis of MTA and Biodentine cements for use in endodontics by using micro?computed tomography
2018
Background The purpose of this study is to compare the porosity of two repair cements, White ProRoot® MTA and Biodentine®. These samples were analyzed by using micro-computed microtomography. Material and methods Sixteen samples were used in the study that were divided according to the composition of the materials used. White ProRoot® MTA (n = 8) and Biodentine® (n = 8) were the samples prepared according to the manufacturer's instructions. They were placed in silicone molds of 5 ± 0.1mm in height and an internal diameter of 5 ± 0.1mm, 24 hours after its preparation, the samples were scanned through a micro-CT, the porosity results were analyzed statistically by independent "t" tests. Resul…
Goldmann Applanation Tonometry Using Sterile Disposable Silicone Tonometer Shields
1996
Abstract Purpose: Placement of a sterile single-use cover over the tonometer tip may be a convenient and safe alternative method to repeated chemical disinfection. This study was undertaken to evaluate the accuracy and performance of Goldmann applanation tonometry using a sterile disposable silicone tonometer shield over the biprism tip. Methods: The same investigator measured intraocular pressure in 120 eyes with and without the shield. The eyes were tested randomly first with either the uncovered or the covered tonometer to control for the possible effects of repeated tonometry influencing measurement differences. Readings were recorded independently in a masked fashion. Results: The intr…
CORRELATION OF OPTICAL COHERENCE TOMOGRAPHY PATTERN AND VISUAL RECOVERY AFTER VITRECTOMY WITH SILICONE OIL FOR RETINAL DETACHMENT
2006
PURPOSE: To assess prospectively the features of the macular surface in silicone oil-filled eyes after surgery by analyzing whether silicone oil affects optical coherence tomography (OCT) measurements and their reproducibility and whether a statistical correlation exists between postoperative best-corrected visual acuity (BCVA) and foveal thickness measured by OCT. METHODS: Twenty eyes of 20 patients underwent vitrectomy with silicone oil tamponade for retinal detachment. After vitrectomy, complete ophthalmic examination including determination of BCVA and OCT was performed to quantify the visual recovery and the foveal thickness. RESULTS: Ophthalmoscopy revealed that the retina appeared to…
Long-term results of the use of silicone sheets after diskectomy in the temporomandibular joint: clinical, radiographic and histopathologic findings
1999
The aim of the present study was to evaluate the long-term results of a group of patients who had the disk of the temporomandibular joint (TMJ) removed and permanently replaced by a silicone sheet. The study group comprised 48 patients, treated in the period from 1983 to 1993. In eight patients, the implants had to be removed after an average interval of 5.6 years and they were submitted for histopathological examination. Twenty-five of the 40 patients with silastic implants in place, and five of the 8 patients who had their implants removed, were available for long-term follow-up (mean interval of 7.0 years, SD 2.8 years). Clinical function was rated according to the Helkimo Dysfunction In…
ACUTE VISION LOSS AS THE ONLY SIGN OF LEUKEMIA RELAPSE.
2016
Purpose To report a case of unilateral exudative retinal detachment as the sole presentation of relapsing B-type lymphoblastic leukemia in a 35-year-old man after 3 years of remission. Methods Case report. Results A 35-year-old man in complete remission of high-risk type B acute lymphoblastic leukemia (ALL-B) presented with acute vision loss in his left eye. Exudative retinal detachment was diagnosed at initial evaluation. Hematological and ocular studies were performed. Although there was no evidence of blood, cerebrospinal fluid, or bone marrow disease relapse, transvitreal retinochoroidal cytology identified the infiltration of lymphoblastic leukemic B cells with t(12:21) translocation a…
Complications of Poly Implant Prothèse breast implants: the current discussion
2013
Against the background of the current discussion about Poly Implant Prothèse (PIP, Seyne-sur-mer, France) breast implants, we want to present a case demonstrating the complications such as implant rupture, silicone dissemination and level III silicone lymphadenopathy. A 29-year-old woman with cosmetic breast augmentation with PIP implants 5 years previously showed a sensitive swelling in her right axilla and neck region. All tests to detect an infectious or lymphomatous lymphadenopathy were negative. After ultrasound and MRI, rupture of the right implant was assumed and multiple pathologically enlarged lymph nodes up to supraclavicular region were shown. An excision biopsy of one axillary l…
Pro-Inflammatory Cytokines in Elective Flap Surgery
2006
Surgical trauma releases inflammatory mediators such as pro-inflammatory cytokines. In this prospective, controlled, randomized trial we investigated the release of pro-inflammatory cytokines and monocyte/macrophage activation in patients scheduled for breast reconstruction after mastectomy. Patients were allocated to one of three surgical procedures, differing in complexity and in the need for implants used for reconstruction.Thirty mastectomized women underwent delayed breast reconstruction with the lateral thoracodorsal flap (LTD), the latissimus dorsi flap (LD), or the pedicled transverse rectus abdominis muscle flap (TRAM). Blood samples for TNF, IL-6, IL-8, neopterin, C-reactive prote…
Morphea after silicone gel breast implantation for cosmetic reasons in an HLA-B8,DR3-positive woman
1997
We describe an HLA-B8, DR3-positive patient with localized morphea after silicone gel breast implantation for cosmetic reasons. We believe that this case suggests that a genetic background, i.e. HLA-B8, DR3 haplotype, is involved in the autoimmune response to silicone.
Polylactic is a Sustainable, Low Absorption, Low Autofluorescence Alternative to Other Plastics for Microfluidic and Organ-on-Chip Applications
2020
Organ-on-chip (OOC) devices are miniaturized devices replacing animal models in drug discovery and toxicology studies. The majority of OOC devices are made from polydimethylsiloxane (PDMS), an elastomer widely used in microfluidic prototyping, but posing a number of challenges to experimentalists, including leaching of uncured oligomers and uncontrolled absorption of small compounds. Here we assess the suitability of polylactic acid (PLA) as a replacement material to PDMS for microfluidic cell culture and OOC applications. We changed the wettability of PLA substrates and demonstrated the functionalization method to be stable over a time period of at least 9 months. We successfully cultured …