Search results for "silicone"

showing 10 items of 78 documents

Granulomatous reactions from silicone: a diagnostic trap for the dermatophalogist.

2011

Granulomatousilicone
researchProduct

Microfabrication of hybrid fluid membrane for microengines

2015

International audience; This paper describes the microfabrication and dynamic characterization of thick membranes providing a technological solution for microengines. The studied membranes are called hybrid fluid-membrane (HFM) and consist of two thin membranes that encapsulate an incompressible fluid. This work details the microelectromechanical system (MEMS) scalable fabrication and characterization of HFMs. The membranes are composite structures based on Silicon spiral springs embedded in a polymer (RTV silicone). The anodic bonding of multiple stacks of Si/glass structures, the fluid filling and the sealing have been demonstrated. Various HFMs were successfully fabricated and their dyna…

HistoryMaterials scienceFabrication020209 energyComposite number02 engineering and technologyEducation[SPI.AUTO]Engineering Sciences [physics]/Automatic[SPI.MAT]Engineering Sciences [physics]/Materials0202 electrical engineering electronic engineering information engineering[PHYS.MECA.MEFL]Physics [physics]/Mechanics [physics]/Fluid mechanics [physics.class-ph]Composite material[SPI.NANO]Engineering Sciences [physics]/Micro and nanotechnologies/MicroelectronicsRTV siliconeComputingMilieux_MISCELLANEOUSchemistry.chemical_classificationMicroelectromechanical systems[SPI.ACOU]Engineering Sciences [physics]/Acoustics [physics.class-ph][SPI.NRJ]Engineering Sciences [physics]/Electric powerPolymer021001 nanoscience & nanotechnologyComputer Science ApplicationsMembranechemistryAnodic bonding[PHYS.MECA.THER]Physics [physics]/Mechanics [physics]/Thermics [physics.class-ph]0210 nano-technologyMicrofabrication
researchProduct

Solvent for removing silicone oil from intraocular lenses: experimental study comparing various biomaterials.

2000

Abstract Purpose To evaluate the effectiveness of a perfluorocarbon—perfluorohexyloctane (PFHO)—in removing silicone oil from different intraocular lenses (IOLs) and determine whether any removal technique enhances the removal of silicone oil. Methods Six IOL materials were analyzed: standard poly(methyl methacrylate) (PMMA), heparin-surface-modified (HSM) PMMA, AcrySof, 2 polyHEMAs with different water contents, and a second-generation SLM-2 silicone. One or 2 μL of a highly viscous silicone oil (5700 cs) was applied to the center of each IOL optic. Perfluorohexyloctane (2 mL) was then used to remove the silicone oil by 1 of 3 techniques: immersion of the IOL in PFHO; irrigation of the sil…

Lens materialsmedicine.medical_specialtyMaterials scienceSurface Propertiesmedicine.medical_treatmentIntraocular lensBiocompatible Materialschemistry.chemical_compoundSiliconemedicineHumansPolymethyl MethacrylateSilicone OilsLenses IntraocularFluorocarbonsComputerized analysisBiomaterialAdhesivenessReproducibility of ResultsSensory SystemsSilicone oilSurgerySolventOphthalmologychemistryIntraocular lensesSolventsMethacrylatesSurgeryBiomedical engineeringJournal of cataract and refractive surgery
researchProduct

Development of a long-lasting ventricular catheter impregnated with a combination of antibiotics.

2003

A ventricular silicone catheter impregnated with a combination of rifampin and a quinolone was developed in order to prevent ventricular shunt related infections. As model substance for the quinolones we used sparfloxacin, because of its specific physicochemical properties resulting in a quantitative detection also in the presence of a second antibiotic. In our study we focused especially on an optimization of the antibiotic release out of the impregnated catheters in order to develop long lasting devices with a broad antimicrobial spectrum. A release-optimized catheter was tested with an in vitro colonization test and additionally with a method developed to examine the spread of bacteria o…

Long lastingmedicine.medical_specialtyProsthesis-Related Infectionsmedicine.drug_classAntibioticsBiophysicsBioengineeringQuinolonesCerebral VentriclesBiomaterialschemistry.chemical_compoundSiliconeCatheters IndwellingDrug Delivery SystemsCoated Materials BiocompatibleStaphylococcus epidermidismedicineStaphylococcus epidermidisDrug Implantsbiologybusiness.industrySterilizationbiology.organism_classificationAntimicrobialQuinoloneSurgeryAnti-Bacterial AgentsEquipment Failure AnalysisCatheterSparfloxacinchemistryMechanics of MaterialsCeramics and CompositesEquipment ContaminationDrug Therapy CombinationRifampinbusinessmedicine.drugBiomaterials
researchProduct

Improved method for cannula fixation for long-term intracerebral brain infusion

2017

Abstract Background Implanted osmotic minipumps are commonly used for long-term, brain-targeted delivery of a wide range of experimental agents by being connected to a catheter and a cannula. During the stereotactical surgery procedure, the cannula has to be placed correctly in the x-y directions and also with respect to the injection point in the z-direction (deepness). However, the flat fixation base of available cannula holders doesn’t allow an easy, secure fixation onto the curve-shaped skull. New method We have developed a modified method for a better fixation of the cannula holder by using an easy-to-produce, skull-shaped silicone spacer as fixation adapter. Results We describe the ap…

Male0301 basic medicinemedicine.medical_specialtySiliconesModified methodImproved methodBrain tissueMice03 medical and health sciencesFixation (surgical)Drug Delivery SystemsImaging Three-Dimensional0302 clinical medicineSurgery procedureSkull surfacemedicineAnimalsCannulabusiness.industryGeneral NeuroscienceBrainInfusion Pumps ImplantableCannulaSurgeryMice Inbred C57BLCatheter030104 developmental biologyTomography X-Ray Computedbusiness030217 neurology & neurosurgeryJournal of Neuroscience Methods
researchProduct

Silicone-Silver Penile Prosthesis: Description, Operative Approach and Results

1980

A silicone penile prosthesis in which silver wires are embedded to allow for voluntary bending of the penis for urination and resting position and for straightening for intercourse is described. The implantation is done via a hemicircular incision on the dorsum of the penis in the sulcus coronarius. Buck's fascia is identified and opened, and the corpora are dilated up to 30F. After the exact length is determined with a special sizer the prosthesis is slipped into each corpus cavernosum. The advantage of this approach is the optimal insertion of the prosthesis distal to the sulcus coronarius, thereby preventing kinking of the glans during intercourse. Our experiences with the implantation i…

MaleDorsummedicine.medical_specialtySilverUrologymedia_common.quotation_subjectmedicine.medical_treatmentProsthesis DesignUrinationProsthesischemistry.chemical_compoundPostoperative ComplicationsSiliconeHumansMedicineGlansmedia_commonbusiness.industryPenile prosthesisProstheses and ImplantsFasciaSurgerymedicine.anatomical_structurechemistrySilicone ElastomersbusinessPenisPenisJournal of Urology
researchProduct

TREATMENT OF PERSISTENTLY OPEN MACULAR HOLES WITH HEAVY SILICONE OIL (DENSIRON 68) VERSUS C2F6. A PROSPECTIVE RANDOMIZED STUDY

2016

Abstract PURPOSE: To compare the efficacy of a mixture of silicone oil and perfluorohexyloctane (Densiron 68) with C2F6 gas endotamponade in the retreatment of persistently open full-thickness macular holes. METHODS: In this prospective randomized study, 21 consecutive patients who were unsuccessfully operated on for large idiopathic full-thickness macular hole were randomly assigned to undergo a second vitrectomy with 20% perfluoroethane gas (C2F6, Group A) or with Densiron 68 tamponade (Group B). PRIMARY OUTCOMES: Endpoint (12 months) full-thickness macular hole closure rate by spectral domain optical coherence tomography and logMAR corrected distance visual acuity. SECONDARY OUTCOMES: po…

MaleReoperationmedicine.medical_specialtyVisual acuitygenetic structuresmedicine.medical_treatmentVisual AcuityVitrectomyEndotamponadelaw.invention03 medical and health scienceschemistry.chemical_compound0302 clinical medicineRandomized controlled triallawVitrectomymedicineHumansSilicone OilsMacular hole Densiron Silicone oilProspective randomized studyProspective StudiesEndotamponadeHeavy silicone oilProspective cohort studyAgedAged 80 and overFluorocarbonsSettore MED/30 - Malattie Apparato Visivobusiness.industryGeneral MedicineMiddle AgedRetinal PerforationsSilicone oilSurgeryOphthalmologychemistry030221 ophthalmology & optometryFemalemedicine.symptombusinessTomography Optical Coherence030217 neurology & neurosurgeryRetina
researchProduct

Heavy versus standard silicone oil in the management of retinal detachment with macular hole in myopic eyes

2011

PURPOSE: The purpose of this study was to compare pars plana vitrectomy (PPV) with 1000 cSt silicone oil endotamponade and PPV with densiron endotamponade for retinal detachment with macular hole and posterior staphyloma in highly myopic eyes. PATIENTS AND METHODS: In a prospective study, 30 eyes of 30 patients were randomly assigned to PPV and densiron (n = 15) or PPV with silicone oil (n = 15). All eyes had laser photocoagulation of the macular hole rim after PPV. Silicone oil or densiron was removed 12 weeks after surgery. Patients were followed-up for 6 months after oil removal. RESULTS: In the densiron group, the retinal reattachment rate was 100% with densiron in situ and 87% after it…

MaleTime FactorsVisual acuityIntraoperative Complicationgenetic structuresmedicine.medical_treatmentVisual AcuityRetinal perforationVitrectomyPostoperative ComplicationsVitrectomySilicone OilsProspective StudiesEndotamponadeIntraoperative ComplicationsMacular holeLaser Coagulationhigh myopic eyeRetinal detachmentGeneral MedicineMiddle AgedTreatment Outcomemedicine.anatomical_structureMyopia Degenerativemacular hole retinal detachmentDrainageFemalemedicine.symptomLaser coagulationDilatation PathologicHumanAdultPars planamedicine.medical_specialtyTime Factorsilicone oilOphthalmologymedicineHumansAgeddensironbusiness.industryRetinal DetachmentRetinal Perforationsmedicine.diseaseeye diseasesProspective StudieOphthalmologyRetinal PerforationPostoperative Complicationsense organsbusiness
researchProduct

A New Model of Skull Base Reconstruction following Expanded Endonasal or Transoral Approaches – Long-Term Results in Primates

2007

<i>Objective:</i> The direct endonasal or transoral transclival approaches to the skull base permit effective minimally invasive surgery along the clivus region. Developing consistently effective techniques to prevent cerebrospinal fluid (CSF) leaks and their consequences (infections and healing processes with long and complicated recoveries) remains a major challenge. In this study, we tested over a long period a method of bone reconstruction newly developed by us, which makes use of a specially designed elastic silicone plug that can be employed for bone replacement after minimally invasive skull base surgery without risk of postoperative CSF leaks. After acute testing of plug…

Malemedicine.medical_specialtySiliconesPostoperative ComplicationsClivusmedicineAnimalsMinimally Invasive Surgical ProceduresBase (exponentiation)Cerebrospinal FluidSkull BaseCerebrospinal Fluid Leakagebusiness.industryForeign-Body ReactionSilicone plugEndoscopyProstheses and ImplantsLong term resultsPlastic Surgery ProceduresAnti-Bacterial AgentsSurgerySkullmedicine.anatomical_structureModels AnimalSkull base surgeryInvasive surgeryPapio hamadryasSurgerybusinessEuropean Surgical Research
researchProduct

Effect of head position on refraction in aphakic and phakic silicone-filled eyes.

1997

BACKGROUND The refraction of the eye is altered significantly after the instillation of silicone oil into the vitreous cavity because of the silicone oil's high refractive index. The degree of the refractive change shows diurnal variation and depends on the patient's head position. PATIENTS AND METHODS To analyze the degree and time course of refractive changes with respect to head position, the authors performed objective refraction in five aphakic and five phakic silicone oil-instilled eyes with attached maculae using an automatic hand-held refractometer. In each patient, 25 measurements were taken at short intervals using a hand-held autorefractometer with the patient in different positi…

Malemedicine.medical_specialtySupine positionVisual acuitygenetic structuresPseudophakiaPostureVisual AcuityAphakia PostcataractRefraction Ocularchemistry.chemical_compoundSiliconeRefractometerOphthalmologyMedicineHumansSilicone Oilsskin and connective tissue diseasesDioptreLenses Intraocularbusiness.industryRetinal DetachmentGeneral MedicineMiddle AgedRefractioneye diseasesSilicone oilOphthalmologyRefractometrychemistryHead positionFemalesense organsmedicine.symptombusinessHeadRetina (Philadelphia, Pa.)
researchProduct