Search results for "solution"
showing 10 items of 5638 documents
Requirements on resolution of digital imaging equipment in the cardiac catheterization laboratory.
1988
We evaluated the requirements on spatial resolution of digital imaging equipment in the cardiac catheterization laboratory. Fifty cinefilms of the heart as the biological object and one film of a lead-ladder-pattern as an objective test were used. The patient films were examined for the visibility of the left ventricular angiogram, coronary arterial tree, coronary artery lesions, branching of septal arteries and the number of septal arteries. All films were viewed three times: with a 625 line TV-system, with a 1249 line TV-system and with a cineprojector. It was found that two application areas with different demands on the spatial and temporal resolution can be distinguished: 1) low spatia…
Technical development in cardiac CT: current standards and future improvements—a narrative review
2020
Non-invasive depiction of coronary arteries has been a great challenge for imaging specialists since the introduction of computed tomography (CT). Technological development together with improvements in spatial, temporal, and contrast resolution, progressively allowed implementation of the current clinical role of the CT assessment of coronary arteries. Several technological evolutions including hardware and software solutions of CT scanners have been developed to improve spatial and temporal resolution. The main challenges of cardiac computed tomography (CCT) are currently plaque characterization, functional assessment of stenosis and radiation dose reduction. In this review, we will discu…
Physicochemical stability of irinotecan injection concentrate and diluted infusion solutions in PVC bags
2000
Purpose. To determine the physicochemical stability of irinotecan injection concentrate and irinotecan infusion solutions after dilution in two commonly used infusion fluids (0.9% sodium chloride, 5% dextrose) in PVC bags, stored under refrigeration (2-8°C) or at room temperature either light protected or exposed to light. Methods. Stability of irinotecan injection concentrate was determined in the original amber glass vials. Diluted irinotecan infusion solutions were aseptically prepared by further dilution of irinotecan stock solution with either 0.9% sodium chloride or 5% dextrose in PVC bags, in amounts yielding irinotecan concentrations of 0.4, 1.0, or 2.8 mg/ml. Test solutions were s…
pH stability of ophthalmic solutions.
2004
Background In this study, we evaluated the pH value of 17 ophthalmic solutions, and we investigated whether the pH of these solutions changed over time after the bottle was opened. Methods Fifteen bottles of each type of solution were chosen at random from different production lots. A 0.05-ml increment was taken from each bottle and was measured daily using a micropH 2002 Crison pH-meter over a period of 30 days. Results The results revealed differences between the pH values of the solutions; nine solutions presented pH values within ocular comfort range and eight solutions presented pH values between 3.5 and 6.4. Ten solutions presented non-statistically significant variations over time ( …
Use of leukocyte and platelet-rich fibrin (L-PRF) in periodontally accelerated osteogenic orthodontics (PAOO): clinical effects on edema and pain
2015
Background Demand for shorter treatment time is common in orthodontic patients. Periodontally Accelerated Osteogenic Orthodontics (PAOO) is a somewhat new surgical procedure which allows faster tooth movement via combining orthodontic forces with corticotomy and grafting of alveolar bone plates. Leukocyte and Platelet-Rich Fibrin (L-PRF) possess hard- and soft-tissue healing properties. Further, evidence of pain-inhibitory and anti-inflammatory potential is growing. Therefore, this study explores the feasibility, intra- and post-operative effects of using L-PRF in PAOO in terms of post-operative pain, inflammation, infection and post-orthodontic stability. Material and methods A pilot prosp…
Differences Between Conventional Anorectal Manometry and High Resolution/High Definition Anorectal Manometry
2020
The book provides a comprehensive overview of high-resolution and high-definition anorectal manometry (HRAM/HDAM), showing the possible benefits of a wider use of these techniques in clinical practice, as well as their limitations. Although these techniques provide fresh insights into anorectal function and offer a new perspective on the pathophysiologic mechanisms of many defecation disturbances, there is a need to clarify whether their use has beneficial effects on clinical management compared to conventional manometry. There is still a considerable way to go to gain the clinical diffusion of esophageal HRM, which has become the gold standard in studying esophageal motility. Indeed, many …
Performing, Analyzing, and Interpreting HRAM and HDAM Recordings
2020
Anorectal manometry is one of the most widely performed tests for the assessment of anal sphincter function and anorectal coordination. Nowadays high resolution (HRAM) and high definition anorectal manometry (HDAM) are available, instead of the water-perfused system. The ability to visualize the anorectum as a dynamic structure during test maneuvers should intuitively allow for a better appreciation of the normal physiology and hopefully enhance our understanding of the pathophysiology of defecatory dysfunctions. Even if the anorectal manometry protocols can vary by centers, the procedure must include an assessment of rectoanal pressure and anal canal length at rest, cough reflex test, rect…
Macular edema: Miscellaneous.
2010
International audience; Abstract. This article provides the reader with practical information to be applied to the various remaining causes of macular edema. Some macular edemas linked to ocular diseases like radiotherapy after ocular melanomas remained of poor functional prognosis due to the primary disease. On the contrary, macular edemas occurring after retinal detachment or after some systemic or local treatment use are often temporary. Macular edema associated with epiretinal membranes or vitreomacular traction is the main cause of poor functional recovery. However, the delay to observe a significant improvement of vision after surgery should be long, as usually observed in tractional …
Letter regarding article titled ‘Microembolism during foam sclerotherapy of varicose veins’ in the New England Journal of Medicine
2008
Myocardial Protection by Retrograde Cardioplegic Perfusion in the Presence of Acute Coronary Artery Obstruction: An Experimental Study
1992
To investigate retrograde delivery of cardioplegic solutions as a means of enhancing myocardial protection in the presence of coronary artery occlusion, a two-part experimental model was devised. In part 1 (in vitro) the possibility of retroperfusing the entire myocardium during acute occlusion of the left anterior descending artery (LAD) was assessed. In part 2 (in vivo) acute LAD occlusion was performed in dogs, and during 2 hours of aortic cross-clamping crystalline cardioplegic solution was infused at 20-minute intervals. In group I the infusion was antegrade, via the aortic root, and in group II it was retrograde, via the coronary sinus. Thereafter the LAD snare was released and the do…