Search results for "spectrometer"

showing 10 items of 751 documents

Identification of unknown pesticides in fruits using ultra-performance liquid chromatography–quadrupole time-of-flight mass spectrometry

2007

Abstract Ultra-high-performance liquid chromatography–quadrupole time-of-flight mass spectrometry (UPLC-QqTOF-MS) is an emerging technique offering more rapid and efficient separation, as well as the possibility to obtain accurate mass measurement and tandem mass spectrometry (MS/MS). This paper deals with the use of UPLC-QqTOF-MS to identify the pesticide residues present in complex pear extracts. Carbendazim, imazalil, and ethoxyquin were successfully identified because of the accurate mass determination of their protonated molecule and their major fragments in the product ion mass spectra. A few plastic and latex additives were also found, most of them probably coming from the packaging …

Detection limitElectrosprayChromatographyCalibration curveChemistryOrganic ChemistryAnalytical chemistryGeneral MedicineTandem mass spectrometryMass spectrometryBiochemistryAnalytical ChemistryTriple quadrupole mass spectrometerLiquid chromatography–mass spectrometryMass spectrumJournal of Chromatography A
researchProduct

Cavity ring down spectrometry for disease diagnostics using exhaled air

2017

In this paper we report the current stage of the development of a cavity ring-down spectrometer (CRDS) system using exhaled human breath analysis for the diagnostics of different diseases like diabetes and later lung cancer. The portable CRDS system is made in ultraviolet spectral region using Nd:Yag laser 266 nm pulsed light. Calibration of the CRDS system was performed using generated samples by KinTek automated permeation tube system and self-prepared mixtures with known concentration of benzene and acetone in air. First experiments showed that the limits of detection for benzene and acetone are several tens of ppb.

Detection limitMaterials scienceSpectrometerAnalytical chemistrymedicine.disease_causeMass spectrometryLaserlaw.inventionchemistry.chemical_compoundBreath gas analysischemistrylawmedicineCalibrationBenzeneUltravioletBiophotonics—Riga 2017
researchProduct

Determination of type A and type B trichothecenes in paprika and chili pepper using LC-triple quadrupole-MS and GC-ECD.

2011

There is a need to develop sensitive and accurate analytical methods for determining deoxynivalenol (DON), HT-2 toxin and T-2 toxin in paprika to properly assess the relevant risk of human exposure. An optimized analytical method for determination of HT-2 toxin and T-2 toxin using capillary gas chromatography with electron capture detection and another method for determination of DON by liquid chromatography-mass spectrometry in paprika was developed. The method for determination of HT-2 toxin and T-2 toxin that gave the best recoveries involved extraction of the sample with acetonitrile-water (84:16, v/v), clean-up by solid-phase extraction on a cartridge made of different sorbent material…

Detection limitResidue (complex analysis)ChromatographyChromatography GasElutionChemistryExtraction (chemistry)Mass SpectrometryAnalytical ChemistryTriple quadrupole mass spectrometerT-2 ToxinHumansSample preparationGas chromatographySolid phase extractionCapsicumTrichothecenesChromatography LiquidTalanta
researchProduct

Some observations on the sensitivity of flow-injection techniques for atomic absorption spectrophotometry

1989

Abstract Different strategies for coupling flow-injection manifolds to atomic absorption spectrometers in order to obtain better sensitivity are compared. Using a T-connector interface, different carriers and flow compensation solvents have been assayed in an attempt to improve the sensitivity of flow-injection analysis. Manganese and copper determinations in sewage sludge have been used as a test system and the analytical parameters of both batch and flow-injection methods are compared.

Detection limitSpectrometerAnalytical chemistrychemistry.chemical_elementManganeseCopperAnalytical ChemistryVolumetric flow ratelaw.inventionchemistrylawSensitivity (control systems)Atomic absorption spectroscopySpectroscopySludgeMicrochemical Journal
researchProduct

Multi-pumping mechanised determination of selenium in natural waters by light emitting diode (LED) spectrometry

2009

It has been developed a fully mechanised procedure for the determination of selenium in waters employing a LED based spectrometer and solenoid multi-pumps as solution propelling devices. The proposed method is based on the reaction of selenium with potassium iodide in an acidic medium to liberate iodine, which oxidizes Variamine Blue to form a violet-colour species which absorb at 530 nm. The system was mechanised using the multicommutation process and a stopped flow strategy in the final step reaction. The analytical curve was linear between 0.010 and 0.500 mg L-1, with an equation ΔA = 0.501 (± 0.004) C and r = 0.999. The limit of detection (3σ/S) obtained for the proposed method was 0.00…

Detection limitSpectrometerNatural waterwaterRelative standard deviationLED-photometryAnalytical chemistrychemistry.chemical_elementmulti-pumpingGeneral ChemistryMass spectrometryIodinemechanised flow systemlaw.inventionchemistrylawmulticommuted flow systemseleniumSeleniumLight-emitting diodeJournal of the Brazilian Chemical Society
researchProduct

Acetone measurements in the exhaled air by the cavity ring-down spectrometry

2020

Our work is focused to develop sensitive optical diagnostic methods for the detection of Volatile Organic Compounds in the breath. For the breath measurements, we have built a cavity ring-down spectrometer, operated in the UV region. The system was tested and calibrated using a KinTek automated permeation tube system with nitrogen as a carrier gas, as well as self- prepared acetone mixtures in air with known concentrations. In this paper, we present results of the measurements of acetone concentration in the breath for the test group of randomly selected 40 people in the age group over 50. We observed the values of acetone concentration in the breath in the range from 0,1 – 80 ppm, with a m…

Detection limitchemistry.chemical_compoundChromatographyMaterials sciencechemistrySpectrometerAcetoneRing downchemistry.chemical_elementPermeationMass spectrometryExhaled airNitrogenBiophotonics—Riga 2020
researchProduct

Thermal lens spectrometric determination of cerium with oxine

1991

Abstract The spectrophotometric and photothermal (TLS) procedures for cerium determination using 8-hydroxyquinoline (oxine), after extraction into chloroform, are compared. Photothermal measurements are made using a coaxial pump/probe thermal lens spectrometer. The use of high-purity reagents at low concentrations permits a decrease in the TLS blank signal and noise, leading to a limit of detection of 9 × 10−9 M (cerium extract concentration), 40-fold lower than the spectrophotometric value. The dynamic range extended up to 6 × 10−7 M and the relative standard deviation for 5 × 10−7 M cerium was 3.9%.

Detection limitmedicine.diagnostic_testSpectrometerChemistryExtraction (chemistry)Analytical chemistrychemistry.chemical_elementPhotothermal therapyAnalytical ChemistryCeriumLiquid–liquid extractionSpectrophotometryReagentmedicineSpectroscopyMicrochemical Journal
researchProduct

3D and multispectral imaging for subcutaneous veins detection.

2009

The first and perhaps most important phase of a surgical procedure is the insertion of an intravenous (IV) catheter. Currently, this is performed manually by trained personnel. In some visions of future operating rooms, however, this process is to be replaced by an automated system. Experiments to determine the best NIR wavelengths to optimize vein contrast for physiological differences such as skin tone and/or the presence of hair on the arm or wrist surface are presented. For illumination our system is composed of a mercury arc lamp coupled to a 10nm band-pass spectrometer. A structured lighting system is also coupled to our multispectral system in order to provide 3D information of the p…

Diagnostic ImagingOptics and PhotonicsComputer sciencemedia_common.quotation_subjectMultispectral imageImage processingInfusions Subcutaneouslaw.inventionCatheterizationVeinsAutomationOpticsImaging Three-DimensionallawMedical imagingImage Processing Computer-AssistedContrast (vision)Humansmedia_commonModels StatisticalSpectroscopy Near-InfraredSpectrometerOrientation (computer vision)business.industryEquipment DesignMercuryLinear discriminant analysisImage EnhancementAtomic and Molecular Physics and OpticsSpectrophotometryArc lampbusinessOptics express
researchProduct

New rotational levels in $^{186}$Re nucleus

2020

International audience; Excited levels of 186 Re have been studied using results of the single γ -ray spectra measurements following the thermal neutron capture reaction. Energies and intensities of more than 500 γ -transitions have been obtained with the high-resolution crystal diffraction spectrometer GAMS5 of ILL. Most of the obtained intense γ -transitions have been placed in the 186 Re level scheme. A number of new levels, as well as the depopulation for levels observed earlier in the 187 Re (p,d)186 Re reaction measurements have been proposed. Structure of 186 Re levels is interpreted in terms of two-quasiparticle plus rotor coupling model and compared with that of the neighbouring do…

DiffractionNuclear and High Energy PhysicsCore plus two-quasiparticles model[PHYS.NUCL]Physics [physics]/Nuclear Theory [nucl-th]Thermal neutron captureNUCLEAR REACTION 185Re[formula omitted]E=thermalMeasured [formula omitted]01 natural sciencesSpectral lineCrystalMeasured Eγ0103 physical sciencesmedicineγ)010306 general physicsPhysicsCouplingSpectrometer010308 nuclear & particles physics186 Re deduced levelsNUCLEAR REACTION 185 Re (nmedicine.anatomical_structureE =thermalExcited stateGAMS5 crystal diffraction spectrometerAtomic physicsNucleus186Re deduced levels
researchProduct

Levels of 188Re nucleus populated in thermal neutron capture reaction

2016

Abstract Levels of 188 Re populated in thermal neutron capture reaction with enriched 187 Re targets have been studied. Single γ -ray spectrum of 188 Re, measured with the high-resolution crystal diffraction spectrometer GAMS5, as well as γγ -coincidence experiments performed with high efficiency Ge detectors, allowed to develop model-independent level scheme of the doubly-odd 188 Re nucleus up to ∼ 1.5 MeV excitation energy. Analysis of the established 188 Re level scheme in terms of the quasiparticle-plus-rotor model indicates coexistence of axially-deformed and triaxial structures in the energy range above 400 keV.

DiffractionNuclear reactionPhysicsNuclear and High Energy PhysicsRange (particle radiation)Spectrometer010308 nuclear & particles physics01 natural sciencesCoincidenceCrystalNuclear physicsmedicine.anatomical_structure0103 physical sciencesmedicineAtomic physics010306 general physicsNucleusExcitationNuclear Physics A
researchProduct