Search results for "spectrometer"
showing 10 items of 751 documents
On the performances of a particle tracking detector based on triangular scintillator bars read out by silicon photomultipliers
2020
Abstract A tracking detector composed of scintillator bars with a triangular cross-section read out by silicon photomultipliers in analog mode was developed. The tracker was designed to instrument a low density spectrometer for neutrino experiments. The performance of the system has been studied by exposing it to charged particle beams at the CERN-PS. The tests have shown that the position resolution in reconstructing charged particles’ tracks is within 2.2 mm over the momentum range 0.5–10 GeV/c.
A CZT 3D imaging spectrometer prototype with digital readout for high energy astronomy
2023
The scientific challenges still open in hard X-rays and γ-rays astronomy require the development of new instrumentation able to overcome the sensitivity limits of the present one. Among the technologies currently under study to cover the energy range between several tens of keV and one MeV, the development of telescopes equipped with broadband Laue lenses associated with focal planes with high spectroscopic and imaging performance represents an extremely promising solution. With this perspective, we report on the development and the first spectroscopic characterisation results of an X/γ rays detection system (10-1000 keV) based on CZT spectrometers with spatial resolution in three dimension…
Silicon Detector Telescope for proton detection in electron scattering reactions at MAMI
2012
Abstract A new Silicon Detector Telescope has been constructed and installed within the experimental facility of the A1 collaboration at Mainz Microtron, with the goal to detect low-energy protons. It consists of seven silicon layers for energy and angle measurement and a plastic scintillator for triggering purposes. The detector subtends a solid angle up to 88 msr, depending on the distance from the target and covers the proton kinetic energy range of 25–41 MeV with the mean energy resolution σ E = 0.47 MeV , operating at 500 kHz. Digital signal processing methods applied for energy reconstruction have been important for keeping the acceptable energy resolution at high counting rates. The…
Measurement and simulation of the pressure ratio between the two traps of double Penning trap mass spectrometers
2008
Penning traps are ideal tools to perform high-precision mass measurements. For this purpose the cyclotron frequency of the stored charged particles is measured. In case of on-line mass measurements of short-lived nuclides produced at radioactive beam facilities the ions get in general first prepared and cooled by buffer-gas collisions in a preparation trap to reduce their motional amplitudes and are then transported to a precision trap for the cyclotron frequency determination. In modern Penning trap mass spectrometers both traps are placed in the homogeneous region of one superconducting magnet to optimize the transport efficiency. Because the gas pressure inside the precision trap has to …
Surface Analysis in Archaeology Using the Miniaturized Mössbauer Spectrometer MIMOS II
2003
A miniaturized Mossbauer spectrometer (MIMOS II) which was designed and constructed for extraterrestrial applications, such as iron-containing rock and soil analysis on the planet Mars, has been employed to investigate the iron-containing constituents in the paintings of a Lekythos Greek vase. Greek pottery is commonly painted with black figures. The Mossbauer backscattering spectra recorded with MIMOS II at room temperature show that the hand-painted black figures contain hematite.
Time-of-flight telescope for heavy-ion RBS
2007
Abstract This paper describes a time-of-flight (TOF) spectrometer for Heavy-Ion Rutherford Backscattering Spectrometry (HI-RBS) recently installed at IMEC for thin film analysis. The TOF telescope allows the use of ion beams heavier than He, with advantages in terms of depth and mass resolution and sensitivity compared to conventional RBS based on planar Si detectors. The start timing-signal is produced by the secondary electrons emitted from a thin C foil when traversed by a backscattered ion; the electrons are deflected in an electrostatic mirror towards a Micro-channel plate (MCP) assembly which provides a fast timing response. The stop signal is obtained directly from a second MCP assem…
High-resolution spectroscopy of gaseous $^\mathrm{83m}$Kr conversion electrons with the KATRIN experiment
2020
In this work, we present the first spectroscopic measurements of conversion electrons originating from the decay of metastable gaseous $^\mathrm{83m}$Kr with the Karlsruhe Tritium Neutrino (KATRIN) experiment. The results obtained in this calibration measurement represent a major commissioning milestone for the upcoming direct neutrino mass measurement with KATRIN. The successful campaign demonstrates the functionalities of the full KATRIN beamline. The KATRIN main spectrometer's excellent energy resolution of ~ 1 eV made it possible to determine the narrow K-32 and L$_3$-32 conversion electron line widths with an unprecedented precision of ~ 1 %.
The BLAST experiment
2009
The Bates large acceptance spectrometer toroid (BLAST) experiment was operated at the MIT-Bates Linear Accelerator Center from 2003 until 2005. The detector and experimental program were designed to study, in a systematic manner, the spin-dependent electromagnetic interaction in few-nucleon systems. As such the data will provide improved measurements for neutron, proton, and deuteron form factors. The data will also allow details of the reaction mechanism, such as the role of final state interactions, pion production, and resonances to be studied. The experiment used: a longitudinally polarized electron beam stored in the South Hall Storage Ring; a highly polarized, isotopically pure, inter…
Time-differential Mössbauer emission spectroscopy: Development of a new spectrometer and first results
1989
A spectrometer for time-differential Mossbauer spectroscopy was developed with a high count rate capability, a good time resolution, and a flexible data handling. Chemical and physical aftereffects following the57Co decay were studied within the cobalt doped systems Turnbulls blue and ZnS.
New time-differential Mössbauer emission measurements on the high-spin→low-spin relaxation in [57Co/Co(phen)3](ClO4)2
1990
Using our new spectrometer for time-differential Mossbauer emission spectroscopy we reinvestigated the high-spin→low-spin relaxation following the57Co(EC)57Fe process in [57Co/Co(phen)3](ClO4)2 (phen=1,10-phenanthroline). In contrast to former investigations we found a temperature dependent initial population less than 1 for the metastable high-spin states. The results and the data evaluation method are presented.