Search results for "spektrometria"

showing 10 items of 59 documents

Processing and Assessment of Spectrometric, Stereoscopic Imagery Collected Using a Lightweight UAV Spectral Camera for Precision Agriculture

2013

Imaging using lightweight, unmanned airborne vehicles (UAVs) is one of the most rapidly developing fields in remote sensing technology. The new, tunable, Fabry-Perot interferometer-based (FPI) spectral camera, which weighs less than 700 g, makes it possible to collect spectrometric image blocks with stereoscopic overlaps using light-weight UAV platforms. This new technology is highly relevant, because it opens up new possibilities for measuring and monitoring the environment, which is becoming increasingly important for many environmental challenges. Our objectives were to investigate the processing and use of this new type of image data in precision agriculture. We developed the entire pro…

010504 meteorology & atmospheric sciencesComputer scienceScienceta11710211 other engineering and technologiesPoint cloudStereoscopyradiometry02 engineering and technologyphotogrammetry01 natural scienceslaw.inventionspectrometryradiometriamaatalouslawbiomassa (teollisuus)photogrammetry; radiometry; spectrometry; hyperspectral; UAV; DSM; point cloud; biomass; agriculturefotogrammetriaagriculture021101 geological & geomatics engineering0105 earth and related environmental sciencesRemote sensingta1132. Zero hungerbiomassuavQHyperspectral imagingta4111photogrammetriaReflectivityhyperspektridsmInterferometryspektrometriahyperspectralPhotogrammetry13. Climate actionRemote sensing (archaeology)GeoreferenceGeneral Earth and Planetary SciencesRadiometrypistepilviPrecision agriculturepoint cloudRemote Sensing
researchProduct

Determination of mercury at picogram level in natural waters with inductively coupled plasma mass spectrometry by using 3D printed metal scavengers

2019

The determination of ultra-trace concentrations of Hg in natural water samples via preconcentration using 3D printed metal scavenger technique followed by inductively coupled plasma mass spectrometry (ICP-MS) was developed. The determination of Hg in certified reference material ERM-CA615 (groundwater) was performed with high accuracy and precision resulting in recovery of 100 ± 3% and RSD <2.5%, respectively. Selective laser sintering (SLS) 3D printing was used to fabricate the scavengers using a mixture of polyamide-12 powder with thiol-functionalized silica. The preconcentration procedure is based on the adsorption of Hg on the scavenger and followed by elution of the preconcentrated Hg …

3d printedmercuryelohopeavesichemistry.chemical_element02 engineering and technology01 natural sciencesBiochemistryAnalytical ChemistryMetalpreconcentration3D-tulostushaitalliset aineetEnvironmental Chemistryinductively coupled plasma mass spectrometryInductively coupled plasma mass spectrometrySpectroscopyvesistötNatural waterultra-trace concentration010401 analytical chemistry3D printing021001 nanoscience & nanotechnology0104 chemical sciencesMercury (element)spektrometriaCertified reference materialschemistryEnvironmental chemistryvisual_artvisual_art.visual_art_mediumnatural water0210 nano-technologyGroundwaterAnalytica Chimica Acta
researchProduct

Optimization of instrumental parameters for improving sensitivity of single particle inductively-coupled plasma mass spectrometry analysis of gold

2021

Single particle inductively-coupled plasma mass spectrometry (spICP-MS) is a promising technique for analysis of engineered nanoparticles, whose utilization has increased substantially over the past years. Optimization of instrumental conditions is, however, crucial to improve the sensitivity and precision of nanoparticle (NP) detection. In this study, the influence of ICP-MS instrumental parameters (nebulizer gas flow, plasma radiofrequency-power and sampling depth) on the signal intensity of gold in spICP-MS was evaluated using dispersions of Au NPs and a solution of dissolved gold. The interaction effects of the main factors were found to have a significant effect on the signal intensity…

AnalytemassaspektrometriaMaterials sciencetutkimuslaitteetAnalytical chemistryMass spectrometry01 natural sciencesSignalAnalytical ChemistryIonoptimointi0103 physical sciencesInstrumentationInductively coupled plasma mass spectrometrymatrix effectSpectroscopy010302 applied physicsDetection limit010401 analytical chemistryAtomic and Molecular Physics and Optics0104 chemical sciencesSpICP-MSParticleinstrumental parametersnanoparticlesnanohiukkasetParticle sizeoptimization
researchProduct

Anion-driven encapsulation of cationic guests inside pyridine[4]arene dimers

2019

Pyridine[4]arenes have previously been considered as anion binding hosts due to the electron-poor nature of the pyridine ring. Herein, we demonstrate the encapsulation of Me4N+ cations inside a dimeric hydrogen-bonded pyridine[4]arene capsule, which contradicts with earlier assumptions. The complexation of a cationic guest inside the pyridine[4]arene dimer has been detected and studied by multiple gas-phase techniques, ESI-QTOF-MS, IRMPD, and DT-IMMS experiments, as well as DFT calculations. The comparison of classical resorcinarenes with pyridinearenes by MS and NMR experiments reveals clear differences in their host–guest chemistry and implies that cation encapsulation in pyridine[4]arene…

Cation bindingmassaspektrometriaanionitDimerpyridinearenes010402 general chemistryDFT calculations01 natural sciencesFull Research Paperdft calculationsIonlcsh:QD241-441chemistry.chemical_compoundlcsh:Organic chemistryPolymer chemistryPyridinesupramolekulaarinen kemiaresorcinarenesInfrared multiphoton dissociationcation bindingAnion bindinglcsh:Science010405 organic chemistryChemistrytiheysfunktionaaliteoriaOrganic ChemistryCationic polymerizationkationit5470104 chemical sciences3. Good healthChemistryion mobility mass spectrometrymacrocycleslcsh:QBeilstein Journal of Organic Chemistry
researchProduct

Chiral self-sorting behaviour of [2.2]paracyclophane-based bis(pyridine) ligands

2019

Two constitutionally isomeric chiral bis(pyridine) ligands based on planar chiral 4,15-difunctionalized [2.2]paracyclophanes were synthesized, the respective enantiomers were separated via HPLC on a chiral stationary phase, and their self-assembly behaviour upon coordination to palladium(ii) ions was studied with regard to chiral self-sorting effects. As proven by NMR spectroscopy, mass spectrometry, CD spectroscopy, UV-Vis spectroscopy and X-ray crystallography both ligands form the expected dinuclear complexes upon coordination to cis-protected di- or tetravalent palladium(ii) ions, respectively, however, with distinct differences concerning their chiral self-sorting ability. peerReviewed

Circular dichroismPalladium compoundsmassaspektrometriaPyridinechemistry.chemical_element010402 general chemistryMass spectrometryLigands01 natural sciencesIonchemistry.chemical_compoundPyridineNMR-spektroskopiaSpectroscopyta116Nuclear magnetic resonance spectroscopyUltraviolet visible spectroscopyMass spectrometry010405 organic chemistryligandsCircular dichroism spectroscopyNuclear magnetic resonance spectroscopyX ray crystallographyliganditkidetiede0104 chemical sciencesorganic chemistryCrystallographychemistrySynthesis (chemical)orgaaninen kemiaEnantiomerPalladiumOrganic Chemistry Frontiers
researchProduct

Ion traps in nuclear physics : recent results and achievements

2016

Ion traps offer a way to determine nuclear binding energies through atomic mass measurements with a high accuracy and they are routinely used to provide isotopically or even isomerically pure beams of short-living ions for post-trap decay spectroscopy experiments. In this review, different ion-trapping techniques and progresses in recent nuclear physics experiments employing low-energy ion traps are discussed. The main focus in this review is on the benefit of recent high accuracy mass measurements to solve some key problems in physics related to nuclear structure, nuclear astrophysics as well as neutrinos. Also, several cases of decay spectroscopy experiments utilizing trap-purified ion sa…

Condensed Matter::Quantum GasesioniliikkuvuusspektrometriaAtomic mass measurementstrap-assisted spectroscopyastrofysiikkaNuclear binding energyhiukkasfysiikkaPhysics experimentsAtomic massNuclear astro-physicsPhysics::Atomic PhysicsDecay spectroscopiesydinfysiikkaMass measurementsIon traps
researchProduct

The Biosynthesis of Rare Homo-Amino Acid Containing Variants of Microcystin by a Benthic Cyanobacterium

2019

Microcystins are a family of chemically diverse hepatotoxins produced by distantly related cyanobacteria and are potent inhibitors of eukaryotic protein phosphatases 1 and 2A. Here we provide evidence for the biosynthesis of rare variants of microcystin that contain a selection of homo-amino acids by the benthic cyanobacterium Phormidium sp. LP904c. This strain produces at least 16 microcystin chemical variants many of which contain homophenylalanine or homotyrosine. We retrieved the complete 54.2 kb microcystin (mcy) gene cluster from a draft genome assembly. Analysis of the substrate specificity of McyB1 and McyC adenylation domain binding pockets revealed divergent substrate specificity …

CyanobacteriamassaspektrometriaMicrocystinstoksiinitPharmaceutical ScienceMicrocystinPlanktothrixcyanobacteriaArticlebiosynteesi03 medical and health scienceschemistry.chemical_compoundBiosynthesisBacterial ProteinsDrug DiscoveryGene clusterpolycyclic compoundspolyketide synthase (PKS)Protein Interaction Domains and MotifsAmino Acid SequenceAmino AcidssyanobakteeritPharmacology Toxicology and Pharmaceutics (miscellaneous)Genelcsh:QH301-705.5Phylogeny030304 developmental biologymass spectrometrychemistry.chemical_classification0303 health sciencesbiology030302 biochemistry & molecular biologyta1182Sequence Analysis DNAbiology.organism_classificationAmino acidEnzymechemistryBiochemistrylcsh:Biology (General)adenylation domainGenes BacterialMultigene Familynonribosomal peptide synthetase (NRPS)hepatotoxinMarine Drugs
researchProduct

Striated muscle-specific serine/threonine-protein kinase beta (SPEGβ) segregates with high- versus low-responsiveness to endurance exercise training

2019

Bidirectional selection for either high or low responsiveness to endurance running has created divergent rat phenotypes of high-response trainers (HRT) and low-response trainers (LRT). We conducted proteome profiling of HRT and LRT gastrocnemius of 10 female rats (body weight 279 ± 35 g; n = 5 LRT and n = 5 HRT) from generation 8 of selection. Differential analysis of soluble proteins from gastrocnemius was conducted by label-free quantitation. Genetic association studies were conducted in 384 Russian international-level athletes (age 23.8 ± 3.4 yr; 202 men and 182 women) stratified to endurance or power disciplines. Proteomic analysis encompassed 1,024 proteins, 76 of which exhibited stat…

MaleentsyymitPhysiologykestävyysharjoitteluliquid chromatography mass spectrometryMuscle ProteinslihaksetSerine threonine protein kinaseRC1200Gene Frequencyendurance trainingProtein Interaction MapsliikuntafysiologiaExercise capacityPhenotypeexercise capacitymedicine.anatomical_structureOrgan SpecificityFemalesportsGlycolysisResearch Articlekinaasitmedicine.medical_specialtymassaspektrometriaresponsiveness to exerciseBiologyProtein Serine-Threonine KinasesPolymorphism Single NucleotideYoung Adultartificial selection modelEndurance trainingInternal medicinePhysical Conditioning AnimalGeneticsmedicineAnimalsHumansco‐immunopreciptiationskeletal muscleBeta (finance)Muscle SkeletalQH426Skeletal musclelabel‐free quantitationMuscle StriatedRatsharjoitusvasteEndocrinologyProtein Kinases
researchProduct

Heavy ion induced Ti X-ray satellite structure for Ti, TiN, and TiO2 thin films

2018

Materials sciencebiologyta114Analytical chemistryX-ray02 engineering and technology021001 nanoscience & nanotechnologybiology.organism_classification01 natural sciencesspectrometryspektrometriatitaanithin films0103 physical sciencesHeavy ionSatellite (biology)titaniumThin filmohutkalvot010306 general physics0210 nano-technologySpectroscopyX-ray Spectrometry
researchProduct

Monte Carlo -simulaatioiden käyttö rekyylispektrometrimittausten analysoinnissa

2010

Monte Carlo -menetelmätrekyylispektrometriasimulointifysiikkaohutkalvot
researchProduct