Search results for "sperimentale"
showing 10 items of 938 documents
Stochastic modeling and prediction of catalytic converters degradation
2009
This paper proposes a stochastic model for describing the degradation process of catalytic converters over time, where the degradation is indirectly measured through the emission of complex hydrocarbons (HC) in legislated driving cycles. The proposed model is the superposition of two processes, the former being a dependent increments process which describes the actual degradation process, and the latter a white noise process which models the experimental errors. In particular, the proposed model assumes that the degradation growth in a small usage interval depends on the degradation level at the beginning of the interval, rather than on the age of the converter. The model has been applied t…
Early warning for VHE gamma-ray flares with the ARGO-YBJ detector
2011
Detecting and monitoring emissions from flaring gamma-ray sources in the very-high-energy (VHE, > 100 GeV) band is a very important topic in gamma-ray astronomy. The ARGO-YBJ detector is characterized by a high duty cycle and a wide field of view. Therefore, it is particularly capable of detecting flares from extragalactic objects. Based on fast reconstruction and analysis, real-time monitoring of 33 selected VHE extragalactic sources is implemented. Flares exceeding a specific threshold are reported timely, hence enabling the follow-up observation of these objects using more sensitive detectors, such as Cherenkov telescopes. (C) 2011 Elsevier B.V. All rights reserved.
Resolution of the ATLAS muon spectrometer monitored drift tubes in LHC Run 2
2019
The momentum measurement capability of the ATLAS muon spectrometer relies fundamentally on the intrinsic single-hit spatial resolution of the monitored drift tube precision tracking chambers. Optimal resolution is achieved with a dedicated calibration program that addresses the specific operating conditions of the 354 000 high-pressure drift tubes in the spectrometer. The calibrations consist of a set of timing offsets and drift time to drift distance transfer relations, and result in chamber resolution functions. This paper describes novel algorithms to obtain precision calibrations from data collected by ATLAS in LHC Run 2 and from a gas monitoring chamber, deployed in a dedicated gas fac…
EXPLORING THE EFFECTS OF DISCUSSION AND TEXT PLANNING STRATEGIES TO ENHANCE AND ASSESS WRITTEN COMMUNICATION SKILLS
2016
A scuola come nella vita, le capacità di comunicazione scritta sono fondamentali. Queste abilità riguardano soprattutto la costruzione di testi per usi e scopi diversi, l’elaborazione efficace delle informazioni, l’uso corretto della forma linguistica. Scrivere significa conoscere le regole grammaticali ma soprattutto riflettere sulle situazioni e sui contesti specifici di realizzazione, considerare le funzioni linguistiche, gli scopi e i bisogni comunicativi. Sempre più spesso lo sviluppo tecnologico alimenta le difficoltà di bambini e ragazzi di produrre discorsi corretti, coerenti e logicamente organizzati. Per promuovere e valutare la competenza espressiva scritta (strutturazione logica…
Charge Sharing and Cross Talk Effects in High-Z and Wide-Bandgap Compound Semiconductor Pixel Detectors
2023
Intense research activities have been made in the development of high-Z and wide-bandgap compound semiconductor pixel detectors for the next generation X-ray and gamma ray spectroscopic imagers. Cadmium telluride (CdTe) and cadmium-zinc-telluride (CdZnTe or CZT) pixel detectors have shown impressive performance in X-ray and gamma ray detection from energies of few keV up to 1 MeV. Charge sharing and cross-talk phenomena represent the typical drawbacks in sub-millimeter pixel detectors, with severe distortions in both energy and spatial resolution. In this chapter, we review the effects of these phenomena on the response of CZT/CdTe pixel detectors, with particular emphasis on the current st…
Digital Pulse-Processing Techniques for X-Ray and Gamma-Ray Semiconductor Detectors
2017
Over the last decade, digital pulse-processing (DPP) electronics have been widely proposed and used for new generation x- and gamma-ray spectrometers. DPP systems, based on direct digitizing and processing of detector signals, lead to better results than the traditional analog pulse-processing electronics in terms of stability, flexibility, reproducibility, energy resolution, throughput, and dead time. In this chapter, we will review the principles of operation of conventional analog electronic chains for x- and gamma-ray semiconductor detectors, with special emphasis on the benefits of the digital approach. The characteristics of a new real-time DPP system, developed by our group, are disc…
High-Z Materials for X-ray Detection: Material Properties and Characterization Techniques
2023
This book will provide readers with a good overview of some of most recent advances in the field of High-Z materials. There will be a good mixture of general chapters in both technology and applications in opto-electronics, X-ray detection and emerging optoelectronics applications. The book will have an in-depth review of the research topics from world-leading specialists in the field.
CDTE AND CDZNTE PIXEL DETECTORS FOR X-RAY SPECTROSCOPIC IMAGING
2012
Cadmium telluride (CdTe) and cadmium zinc telluride (CdZnTe) wide band gap semiconductors for x-ray detectors have experienced a rather rapid development in the last few years. Among the traditional x-ray detectors based on silicon (Si) and germanium (Ge), CdTe and CdZnTe detectors show higher detection efficiency at high energies and good room temperature performance and are well suited for the development of compact detection systems and pixel arrays for simultaneous measurements of photon interaction position and energy. This chapter is an introduction to the physics and the technology of CdTe and CdZnTe pixel detectors for x-ray spectroscopy and imaging. The physical properties of CdTe …
Time-dependent current-voltage characteristics of Al/p-CdTe/Pt x-ray detectors
2012
Current-voltage (I-V) characteristics of Schottky Al/p-CdTe/Pt detectors were investigated in dark and at different temperatures. CdTe detectors with Al rectifying contacts, very appealing for high resolution x-ray and gamma ray spectroscopy, suffer from bias-induced polarization phenomena which cause current increasing with the time and severe worsening of the spectroscopic performance. In this work, we studied the time-dependence of the I-V characteristics of the detectors, both in reverse and forward bias, taking into account the polarization effects. The I-V measurements, performed at different time intervals between the application of the bias voltage and the measurement of the current…
Study of optical absorbance and MR relaxation of Fricke xylenol orange gel dosimeters
2017
Abstract Studies on the optical absorbance spectra of Fricke xylenol orange gel dosimeters were performed, in the wavelength range from 300 nm to 800 nm, in order to highlight some particular characteristics that can affect the achievable precision. The spectra are different mainly due to the different types of xylenol orange that was used and to a lower extent due to the different gelling agents (agarose or gelatine). The characteristic of variation of absorbance spectra versus dose, however, are similar in the various cases and can explain some peculiarities, as apparent effects of dose threshold. Changes of spectral shapes appear over the time after irradiation. Magnetic resonance measur…