Search results for "spray"

showing 10 items of 503 documents

[Ag67(SPhMe2)32(PPh3)8]3+: Synthesis, Total Structure, and Optical Properties of a Large Box-Shaped Silver Nanocluster

2016

Engineering the surface ligands of metal nanoparticles is critical in designing unique arrangements of metal atoms. Here, we report the synthesis and total structure determination of a large box-shaped Ag67 nanocluster (NC) protected by a mixed shell of thiolate (2,4-dimethylbenzenethiolate, SPhMe2) and phosphine (triphenylphosphine, PPh3) ligands. Single crystal X-ray diffraction (SCXRD) and electrospray ionization mass spectrometry (ESI-MS) revealed the cluster formula to be [Ag67(SPhMe2)32(PPh3)8]3+. The crystal structure shows an Ag23 metal core covered by a layer of Ag44S32P8 arranged in the shape of a box. The Ag23 core was formed through an unprecedented centered cuboctahedron, i.e.,…

CuboctahedronElectrospray ionizationnanoclusters02 engineering and technologyElectronic structureCrystal structure010402 general chemistry01 natural sciencesBiochemistryCatalysisMetalchemistry.chemical_compoundColloid and Surface ChemistryTriphenylphosphinemetal nanoparticlesta116ta114ChemistryLigandGeneral Chemistry021001 nanoscience & nanotechnology0104 chemical sciencesCrystallographysurface ligandsvisual_artvisual_art.visual_art_medium0210 nano-technologySingle crystalJournal of the American Chemical Society
researchProduct

Randomized placebo-controlled trial comparing fluticasone aqueous nasal spray in mono-therapy, fluticasone plus cetirizine, fluticasone plus monteluk…

2004

BACKGROUND: Corticosteroids are considered to be particularly effective in reducing nasal congestion and are therefore recommended as first-line treatment in allergic rhinitis patients with moderate to severe and/or persistent symptoms. OBJECTIVE: We compared the clinical efficacy of fluticasone propionate aqueous nasal spray (FPANS) 200 microg given once daily, administered in mono-therapy or combined therapy with a H1 receptor antagonist (cetirizine, CTZ) or with a leukotriene antagonist (montelukast, MSK), and the combined therapy of CTZ plus MSK in the treatment of patients affected by allergic rhinitis to Parietaria during natural pollen exposure. In addition, we examined the effect of…

CyclopropanesMaleAllergySettore MED/09 - Medicina Internamedicine.medical_treatmentseasonal allergic rhinitisAcetatesGastroenterologyImmunology and AllergyMedicineChildFluticasonepollen seasonRandomized placebo-controlled trialBlood Proteinsrespiratory systemEosinophil Granule ProteinsMiddle AgedCetirizineAnesthesiamontelukastHistamine H1 AntagonistsQuinolineseosinophil cationic proteinDrug Therapy CombinationFemaleeosinophilsmedicine.symptommedicine.drugAdultmedicine.medical_specialtyAdolescentImmunologyNasal congestionSulfidesPlaceboFluticasone propionateDrug Administration ScheduleRibonucleasesDouble-Blind MethodInternal medicineHumansRandomized placebo-controlled trial; fluticasone; cetirizine; montelukast; seasonal allergic rhinitisGlucocorticoidsMontelukastAdministration IntranasalAnalysis of Variancerhinorrheafluticasone propionatebusiness.industrynasal lavageRhinitis Allergic Seasonalmedicine.diseaseCetirizineAndrostadienesParietariaNasal sprayFluticasoneLeukotriene AntagonistsNasal administrationbusinessClinical and experimental allergy : journal of the British Society for Allergy and Clinical Immunology
researchProduct

Recent advances on ionic liquid uses in separation techniques

2018

International audience; The molten organic salts with melting point below 100°C, commonly called ionic liquids (ILs) have found numerous uses in separation sciences due to their exceptional properties as non molecular solvents, namely, a negligible vapor pressure, a high thermal stability, and unique solvating properties due to polarity and their ionic character of molten salts. Other properties, such as viscosity, boiling point, water solubility, and electrochemical window, are adjustable playing with which anion is associated with which cation. This review focuses on recent development of the uses of ILs in separation techniques actualizing our 2008 article (same authors, J. Chromatogr. A…

Deep eutectic solventSpectrometry Mass Electrospray IonizationChromatography Gasgas chromatographydeep eutectic solventLiquid chromatographyIonic bonding02 engineering and technologyTrace anion detection01 natural sciencesBiochemistryAnalytical Chemistryionic liquidschemistry.chemical_compoundCountercurrent chromatographyCapillary electrophoresistrace anion detection[CHIM.ANAL]Chemical Sciences/Analytical chemistryliquid chromatographyCountercurrent DistributionGas chromatographyChromatographyViscosity010401 analytical chemistryOrganic ChemistryElectrophoresis CapillaryGeneral Medicine021001 nanoscience & nanotechnologyIonic liquids0104 chemical sciencesDeep eutectic solventBoiling pointchemistryIonic liquidSolventsMelting pointGases0210 nano-technologyChromatography LiquidElectrochemical windowJournal of Chromatography A
researchProduct

Caractérisation et prédiction du rendement de projection lors du procédé de projection à froid – cas de la métallisation des polymères

2020

This thesis work deals with the cold spray metallization of polymer substrates by aiming at an optimal deposition efficiency using experimental analysis combined with numerical simulation. Experimental observations of the powder jet using an ombroscopic analysis have revealed a generic behavior consisting of a uniform confined zone at the immediate exit of the nozzle followed by a dispersed zone. The supersonic flow at the nozzle exit being essentially axial, the powders are entrained to form a uniform jet. Beyond a certain distance, a dispersion appears. This distance is very important because it characterizes the behavior of the powders. It can alter the conditions for the elaboration of …

Deposition Efficiency (DE)Conductivité électriqueCold SprayRendement de projectionElectrical conductivityProjection à froidAnalyse CFDDispersionMétallisation des polymères[SPI.MAT] Engineering Sciences [physics]/MaterialsCFD analysis[SPI.MAT]Engineering Sciences [physics]/MaterialsMetallization of polymers
researchProduct

Critical assessment of ionization patterns and applications of ambient desorption/ionization mass spectrometry using FAPA-MS

2016

Ambient desorption/ionization mass spectrometry (MS) has gained growing interest during the last decade due to its high analytical performance and yet simplicity. Here, one of the recently developed ambient desorption/ionization MS sources, the flowing atmospheric-pressure afterglow (FAPA) source, was investigated in detail regarding background ions and typical ionization patterns in the positive as well as the negative ion mode for a variety of compound classes, comprising alkanes, alcohols, aldehydes, ketones, carboxylic acids, organic peroxides and alkaloids. A broad range of signals for adducts and losses was found, besides the usually emphasized detection of quasimolecular ions, i.e. […

Desorption electrospray ionizationChemical ionizationChemistry010401 analytical chemistryAnalytical chemistryAtmospheric-pressure chemical ionization010402 general chemistryMass spectrometry01 natural sciencesIon source0104 chemical sciencesAtmospheric-pressure laser ionizationDirect electron ionization liquid chromatography–mass spectrometry interfaceSpectroscopyAmbient ionizationJournal of Mass Spectrometry
researchProduct

A new interface to couple thin-layer chromatography with laser desorption/atmospheric pressure chemical ionization mass spectrometry for plate scanni…

2005

An interface to allow on-line qualitative and quantitative full-plate detection and analysis of compounds separated by thin-layer chromatography (TLC) is presented. A continuous wave diode laser is employed as a desorption source. Atmospheric pressure chemical ionization mass spectrometry ionizes and subsequently identifies the desorbed sample molecules. Besides direct laser desorption on untreated TLC plates, graphite particles were used as a matrix to couple in the laser power and improve the efficiency of desorption.

Desorption electrospray ionizationChromatographyMatrix-assisted laser desorption electrospray ionizationChemistryOrganic ChemistryAnalytical chemistryEquipment DesignMass spectrometryIon sourceSoft laser desorptionAnalytical ChemistryAtmospheric-pressure laser ionizationSpecimen HandlingEquipment Failure AnalysisSystems IntegrationAtmospheric PressureSpectrometry Mass Matrix-Assisted Laser Desorption-IonizationDirect electron ionization liquid chromatography–mass spectrometry interfaceSpectroscopyAmbient ionizationRapid communications in mass spectrometry : RCM
researchProduct

Measurement of nanoparticle mass distributions by laser desorption/ionization time-of-flight mass spectrometry.

2011

In this paper, access to the mass distribution analysis of nanoparticles is described based on laser desorption/ionization and time of flight mass spectrometry. Two examples are given, demonstrating the accurate mass distribution analysis of nanoparticles fabricated both ex situ and in situ during the laser-assisted desorption process. The potentials and the limitations of the method are discussed, with special emphasis on carbonaceous clusters and molecules.

Desorption electrospray ionizationStatic secondary-ion mass spectrometryMatrix-assisted laser desorption electrospray ionizationChemistryAnalytical chemistryGeneral Materials ScienceTime-of-flight mass spectrometryCondensed Matter PhysicsMass spectrometrySoft laser desorptionIon sourceAmbient ionizationJournal of physics. Condensed matter : an Institute of Physics journal
researchProduct

Bromine speciation in volcanic plumes: new in situ derivatization LC-MS method for the determination of gaseous hydrogen bromide by gas diffusion den…

2020

The chemical characterization of volcanic gas emissions gives insights into the interior of volcanoes. Monitoring of BrO/SO2-ratios has recently been correlated with changes in the activity of a volcano. BrO and SO2 can both be measured autonomously and simultaneously with the same instruments from a safe distance, making their ratio potentially a strong monitoring tool. However, BrO is not a primary emitted volcanic volatile and there exist still uncertainties about the formation of BrO in volcanic plumes, mostly due to the lack of analytical approaches for the accurate speciation of certain key compounds. This study describes a new method for the determination of the BrO precursor, the ga…

Detection limitAtmospheric ScienceBromine010504 meteorology & atmospheric sciencesElectrospray ionizationDiffusionTA715-787Analytical chemistrychemistry.chemical_elementEnvironmental engineeringTA170-17101 natural sciencesPlumechemistry.chemical_compoundchemistryEarthwork. FoundationsBromideGaseous diffusionDerivatization0105 earth and related environmental sciences
researchProduct

Identification of unknown pesticides in fruits using ultra-performance liquid chromatography–quadrupole time-of-flight mass spectrometry

2007

Abstract Ultra-high-performance liquid chromatography–quadrupole time-of-flight mass spectrometry (UPLC-QqTOF-MS) is an emerging technique offering more rapid and efficient separation, as well as the possibility to obtain accurate mass measurement and tandem mass spectrometry (MS/MS). This paper deals with the use of UPLC-QqTOF-MS to identify the pesticide residues present in complex pear extracts. Carbendazim, imazalil, and ethoxyquin were successfully identified because of the accurate mass determination of their protonated molecule and their major fragments in the product ion mass spectra. A few plastic and latex additives were also found, most of them probably coming from the packaging …

Detection limitElectrosprayChromatographyCalibration curveChemistryOrganic ChemistryAnalytical chemistryGeneral MedicineTandem mass spectrometryMass spectrometryBiochemistryAnalytical ChemistryTriple quadrupole mass spectrometerLiquid chromatography–mass spectrometryMass spectrumJournal of Chromatography A
researchProduct

Pressurised liquid extraction and capillary electrophoresis–mass spectrometry for the analysis of pesticide residues in fruits from Valencian markets…

2010

Abstract A procedure based in capillary electrophoresis–mass spectrometry (CE–MS) for the analysis of seven pesticides (flutolanil, simazine, haloxyfop, acifluorfen, dinoseb, picloram, and ioxynil) in four Mediterranean summer fruits with high water content (peaches, melon, watermelon, and apricot) is developed. Several conditions were studied for the optimisation of both, the separation and the electrospray (ESI) connection. The best results were obtained using 35 mM ammonium formiate (pH 9.7) as separation buffer, 20 °C as capillary temperature and 23 kV as applied voltage in an uncoated fused-silica capillary with 50 cm total length, 25 cm thermostated length, 25 cm at room temperature l…

Detection limitElectrosprayChromatographyPesticide residueChemistryFormic acidExtraction (chemistry)General MedicineMass spectrometryCapillary electrophoresis–mass spectrometryAnalytical Chemistrychemistry.chemical_compoundCapillary electrophoresisFood ScienceFood Chemistry
researchProduct