Search results for "strah"
showing 10 items of 123 documents
Photoelectron Emission from Metal Surfaces Induced by Radiation Emitted by a 14 GHz Electron Cyclotron Resonance Ion Source
2015
Photoelectron emission measurements have been performed using a room-temperature 14 GHz ECR ion source. It is shown that the photoelectron emission from Al, Cu, and stainless steel (SAE 304) surfaces, which are common plasma chamber materials, is predominantly caused by radiation emitted from plasma with energies between 8 eV and 1 keV. Characteristic X-ray emission and bremsstrahlung from plasma have a negligible contribution to the photoelectron emission. It is estimated from the measured data that the maximum conceivable photoelectron flux from plasma chamber walls is on the order of 10% of the estimated total electron losses from the plasma. peerReviewed
Effects of magnetic configuration on hot electrons in a minimum-B ECR plasma
2020
International audience; To investigate the hot electron population and the appearance of kinetic instabilities in highly charged electron cyclotron resonance ion source (ECRIS), the axially emitted bremsstrahlung spectra and microwave bursts emitted from ECRIS plasma were synchronously measured on SECRAL-II (Superconducting ECR ion source with Advanced design in Lanzhou No. II) ion source with various magnetic field configurations. The experimental results show that when the ratio of the minimum field to the resonance field (i.e. Bmin/Becr ) is less than ~0.8, the bremsstrahlung spectral temperature Ts increases linearly with the Bmin/Becr –ratio when the injection, extraction and radial mi…
Cyclotron instability in the afterglow mode of minimum-B ECRIS.
2016
It was shown recently that cyclotron instability in non-equilibrium plasma of a minimum-B electron cyclotron resonance ion source (ECRIS) causes perturbation of the extracted ion current and generation of strong bursts of bremsstrahlung emission, which limit the performance of the ion source. The present work is devoted to the dynamic regimes of plasma instability in ECRIS operated in pulsed mode. Instability develops in decaying plasma shortly after heating microwaves are switched off and manifests itself in the form of powerful pulses of electromagnetic emission associated with precipitation of high energy electrons. Time-resolved measurements of microwave emission bursts are presented. I…
The high-resolution far-infrared spectrum of methane at the SOLEIL synchrotron
2010
International audience; As a tetrahedral molecule, methane has no permanent dipole moment. Its spectrum, however, displays faint absorption lines in the THz region, due to centrifugal distorsion effects. This is important for planetary applications since this region is used to measure methane concentration in some planetary atmospheres, in particular on Titan. Up to now, all measurements relied either on some old low resolution infrared absorption spectra, or on high resolution Stark measurements for low J values only. Even if these results have been reexamined recently [E. H. Wishnow, G. S. Orton, I. Ozier and H. P. Gush, J. Quant. Spectrosc. Radiat. Transfer 103, 102-117 (2007)], it seeme…
Isomeric state of $^{80}$Y and its role in the astrophysical rp-process
2001
5 pages, 7 figures.-- PACS nrs: 21.10.Tg; 23.20.Nx; 27.50.+e.
International workshop on next generation gamma-ray source
2022
Journal of physics / G 49(1), 010502 (2022). doi:10.1088/1361-6471/ac2827
Determination of phosphorus by instrumental neutron activation and bremsstrahlung measurement in bone samples
1997
A non destructive method based on the31P(n,γ)32P reaction for the assay of phosphorus in bone samples is described. This method involves a thermal neutron irradiation of 2 minutes in a reactor followed by the measurement of the bremsstrahlung produced by the β− of32P in a Ge-detector surrounded by an anti-Compton shield. Accuracy and precision were tested by analysing the certified NIST 1486 Bone Meal reference material and tri-calcium phosphate (Ca3(PO4)2) samples. The value obtained for the reference material was in good agreement with the certified value and with relative standard deviation of 4.1% the precision was acceptable. The value obtained for Ca3(PO4)2 shows a deviation of −6% fr…
Modelling accretion disc and stellar wind interactions: the case of Sgr A*
2016
Sgr A* is an ideal target to study low-luminosity accreting systems. It has been recently proposed that properties of the accretion flow around Sgr A* can be probed through its interactions with the stellar wind of nearby massive stars belonging to the S-cluster. When a star intercepts the accretion disk, the ram and thermal pressures of the disk terminate the stellar wind leading to the formation of a bow shock structure. Here, a semi-analytical model is constructed which describes the geometry of the termination shock formed in the wind. With the employment of numerical hydrodynamic simulations, this model is both verified and extended to a region prone to Kelvin-Helmholtz instabilities. …
Studies of electron heating on a 6.4 GHz ECR ion source through measurement of diamagnetic current and plasma bremsstrahlung
2011
Diamagnetic current and low energy (2–70 keV) x-ray bremsstrahlung measurements taken on a 6.4 GHz electron cyclotron resonance ion source (ECRIS) are presented as a function of microwave power, neutral gas pressure and magnetic field configuration. X-ray flux from confined electrons and plasma energy density depend logarithmically on microwave power. This result differs from previous studies performed on ECRISs that operate at higher microwave frequencies, in which the x-ray power increases in an essentially linear fashion with the microwave power. X-ray power and plasma energy density both saturate as the neutral pressure is increased beyond a certain value. The gradient of the magnetic f…
Nanoelectron spectroscopy for chemical analysis: a novel energy filter for imaging x-ray photoemission spectroscopy
2005
An ovel instrument for imaging ESCA is described. It is based on a tandem arrangement of two hemispherical energy analysers used as an imaging energy filter. The main spherical aberration (α 2 -term) of the analyser is corrected by the antisymmetry of the tandem configuration. The kinetic energy range useable for imaging extends up to 1.6 keV; this is compatible with Mg and Al Kα laboratory x-ray sources. First experiments on the chemical surface composition of a Cu0.98Bi0.02 polycrystal, a GaAs/AlGaAs heterostructure and Ag crystallites on Si(111) have been performed using synchrotron radiation. The results reveal an energy resolutio no f190 meV and a lateral resolution (edge resolution) o…