Search results for "strip"
showing 10 items of 415 documents
Internal alignment and position resolution of the silicon tracker of DAMPE determined with orbit data
2017
Abstract The DArk Matter Particle Explorer (DAMPE) is a space-borne particle detector designed to probe electrons and gamma-rays in the few GeV to 10 TeV energy range, as well as cosmic-ray proton and nuclei components between 10 GeV and 100 TeV. The silicon–tungsten tracker–converter is a crucial component of DAMPE. It allows the direction of incoming photons converting into electron–positron pairs to be estimated, and the trajectory and charge (Z) of cosmic-ray particles to be identified. It consists of 768 silicon micro-strip sensors assembled in 6 double layers with a total active area of 6.6 m 2 . Silicon planes are interleaved with three layers of tungsten plates, resulting in about o…
Construction of two large-size four-plane micromegas detectors
2015
We report on the construction and initial performance studies of two micromegas detector quadruplets with an area of 0.5 m$^2$. They serve as prototypes for the planned upgrade project of the ATLAS muon system. Their design is based on the resistive-strip technology and thus renders the detectors spark tolerant. Each quadruplet comprises four detection layers with 1024 readout strips and a strip pitch of 415 $\mu$m. In two out of the four layers the strips are inclined by $\pm$1.5$^{\circ}$ to allow for the measurement of a second coordinate. We present the detector concept and report on the experience gained during the detector construction. In addition an evaluation of the detector perfor…
The Belle II vertex detector integration
2019
Belle II DEPFET, PXD, and SVD Collaborations: et al.
Operational experience with a large detector system using silicon strip detectors with double sided readout
1992
Abstract A large system of silicon strip detectors with double sided readout has been successfully commissioned over the course of the last year at the e + e − collider LEP. The readout of this 73 728 channel system is performed with custom designed VLSI charge sensitive amplifier chips (CAMEX64A). An overall point resolution of 12 μm on both sides has been acheived for the complete system. The most important difficulties during the run were beam losses into the detector, and a chemical agent deposited onto the electronics; however, the damage from these sources was understood and brought under control. This and other results of the 1991 data-taking run are described with special emphasis o…
COMPASS—A COMPAct decay spectroscopy set-up
2018
Abstract A compact silicon detector array with high spatial granularity and fast, fully digital data recording has been developed and commissioned for the investigation of heavy and superheavy nuclear species. The detector array can be combined in close geometry with large volume germanium detectors. It offers comprehensive particle and photon coincidence and correlation spectroscopy by highly efficient evaporation residue, α , γ , conversion electron and X-ray detection supported by the high granularity of the implantation chip. Access to fast decay events in the sub-microsecond region is made possible by the fast timing properties of the digital signal processing. A novel Si-chip support …
The COMPASS experiment at CERN
2007
The COMPASS experiment makes use of the CERN SPS high-intensitymuon and hadron beams for the investigation of the nucleon spin structure and the spectroscopy of hadrons. One or more outgoing particles are detected in coincidence with the incoming muon or hadron. A large polarized target inside a superconducting solenoid is used for the measurements with the muon beam. Outgoing particles are detected by a two-stage, large angle and large momentum range spectrometer. The setup is built using several types of tracking detectors, according to the expected incident rate, required space resolution and the solid angle to be covered. Particle identification is achieved using a RICH counter and both…
Decay of the high-spin isomer in 160Re: Changing single-particle structure beyond the proton drip line
2011
WOS: 000286708700015
Search for flavor-changing neutral current and lepton-flavor violating decays of D-0 -> l(+)l(-)
2004
We report on a search for the flavor-changing neutral current decays $\Dz\to e^+e^-$ and $\Dz\to\mu^+\mu^-$, and the lepton-flavor violating decay $\Dz\to e^\pm\mu^\mp$. The measurement is based on $122 {fb}^{-1}$ of data collected by the \babar detector at the PEP-II asymmetric $e^+e^-$ collider. No evidence is found for any of the decays. The upper limits on the branching fractions, at the 90 % confidence level, are $1.2\times 10^{-6}$ for $\Dz\to e^+e^-$, $1.3\times 10^{-6}$ for $\Dz\to\mu^+\mu^-$, and $8.1\times 10^{-7}$ for $\Dz\to e^\pm\mu^\mp$.
Enhanced H2O2 production over Au-rich bimetallic Au-Pd nanoparticles on ordered mesoporous carbons
2015
1 figures, 3 tables.-- © 2014. This manuscript version is made available under the CC-BY-NC-ND 4.0 license http://creativecommons.org/licenses/by-nc-nd/4.0/
Ruthenium and Osmium Complexes of Phosphine-Porphyrin Derivatives as Potential Bimetallic Theranostics: Photophysical Studies
2015
A series of (η6-p-cymene)ruthenium(II)- and osmium(II) complexes of porphyrin-phosphane derivatives have been synthesized as potential bimetallic theranostic candidates. The photophysical and electrochemical properties were investigated, and these species desirably exhibit no or almost no photoinduced intramolecular atom, energy, and electron transfer between the dye and the metallic fragment. These favorable features are mostly associated with the presence of their long chain (i.e., ∼ 1 nm) separating the two functional units. Interestingly, a decrease in emission intensity and lifetimes (up to 35-fold) has been observed, which was ascribed to a small heavy atom effect. This effect is poss…