Search results for "stripping"
showing 10 items of 63 documents
Biochar from byproduct to high value added material – A new adsorbent for toxic metal ions removal from aqueous solutions
2018
Abstract An activated biochar coming from pyrolysis of dead Posidonia oceanica residues has been tested as adsorbent material for Cd2+, Pb2+ and Cu2+ ions. The biomass, the activated and the non activated biochars were previously characterized by using several instrumental techniques. The pH of metal ion solution in kinetic and thermodynamic adsorption experiments was fixed at 5 whilst, the dependence on ionic medium, ionic strength and temperature have been evaluated carrying out batch experiments at different experimental conditions. Differential Pulse Anodic Stripping Voltammetry and Inductively Coupled Plasma Optical Emission Spectroscopy have been used to measure the metal ion concentr…
Electrochemical determination of boron in minerals and ceramic materials
2004
Abstract A method for quantitatively determining boron in minerals and ceramic materials is described. It is based on the abrasive attachment of mixtures of ZnO plus sample to PIGEs. After a reductive deposition step, square wave voltammograms recorded for those modified electrodes immersed into 0.10 M NaCl+0.25 M mannitol provide well-defined stripping peaks at −0.85 and −0.15 V vs. AgCl/Ag for the oxidation of Zn and B, respectively. The quotients between the peak areas and the peak currents for the stripping oxidation of B and Zn vary linearly with the molar ratio of B and Zn in the mixture, thus providing an electrochemical method for determining the boron content in solid samples. Resu…
Purification of recovered phosphoric acid by extracting aluminium with di-2-ethylhexyl phosphoric acid
2021
AbstractThe extraction of aluminium from dilute phosphoric acid with di-2-ethylhexyl phosphoric acid (DEHPA) was optimized using response surface methodology. The optimization was based on the experimental three-level central composite face-centred design (CCF) and was conducted on real-life samples. The three variables included were pH, extractant concentration and aqueous to organic phase ratio (AO). Under the optimized conditions (pH 2.5, 0.6 M DEHPA and AO ratio 1:2), extraction efficiency of 99% for aluminium in four extraction stages is achieved. The purified phosphoric acid solution can then be utilized by the fertilizing industry. Stripping tests for organic phase loaded with alumin…
The pH of the Human Nail Plate
2017
In this chapter, measurements of the nail plate pH are reported. Measurements were conducted in vivo in 37 volunteers with healthy finger- and toenails, using a skin pH meter. The pH of unwashed and washed fin- gernails and the big toenails was measured, and the influence of washing, anatomical site (fin- gers/toes), side (left/right), finger digit (digits 1–5), and gender were determined. The pH of the nail plate surface was around 5. There was no significant difference between the sides, i.e., the right or left hand/foot, among the ten fin- gernails and between the two great toenails. However, toenails had a significantly higher pH than fingernails. Washing the nails caused an immediate, …
Electrochemical identification of metal ions in archaeological ceramic glazes by stripping voltammetry at graphite/polyester composite electrodes
2002
The electrochemical response of metal ions in different samples of coloured ceramic tin-lead glazes attached to graphite/polyester composite electrodes is described. In addition to the ubiquous signals for lead, reductive dissolution processes are followed by anodic stripping peaks for Co, Cu, Sb, Mn, Sn and Fe, enabling the direct identification of such elements in microsamples proceeding from archaeological glazed tiles from Valencia (Spain) workshops (16th-18th century). Additional anodic and cathodic peaks corresponding to redox processes involving metal species in solution generated during stripping processes are also used. Peak potentials, Tafel plots and shape parameters are used for…
Variation in somatic cell count, California mastitis test, and electrical conductivity among various fractions of ewe's milk.
1991
Abstract Variation of three estimates of udder inflammation (SCC, California mastitis test, and electrical conductivity) among the foremilk, machine milk, and hand stripping samples were studied. Foremilk and hand stripping milks were taken from each individual teat; machine milk was taken from the entire udder. For this experiment a total of 30 Manchega ewes were subjected to machine milking during the 9th wk of lactation. Samples were taken in duplicate during two milkings on consecutive mornings. Significant differences were observed in the SCC and electrical conductivity, but not in California mastitis test, between foremilk and stripping milk The stripping fraction had higher SCC (70 ±…
Inverse-voltammetric determination of bismuth in biomaterials with computer assisted peak evaluation. part 3. Bismuth determination in wine, grapes a…
1989
The ultra trace element bismuth is regulary found in wine on an average of about 0.1 ppb. Very low bismuth contents were also determined in soil and different biomaterials. In spite of those very low quantities even speciation experiments show results, so far that about 90% of the bismuth in the grapes is water-soluble, resumably as saccharic acids. For detecting such low quantities a very sensitive method of differential pulse anodic stripping voltammetry was developped. The speciation experiments were carried out by fractional extraction.
Thermolytic reverse electrodialysis heat engine: model development, integration and performance analysis
2019
Abstract Salinity gradient heat engines represent an innovative and promising way to convert low-grade heat into electricity by employing salinity gradient technology in a closed-loop configuration. Among the aqueous solutions which can be used as working fluid, ammonium bicarbonate-water solutions appear very promising due to their capability to decompose at low temperature. In this work, an experimentally validated model for a reverse electrodialysis heat engine fed with ammonium bicarbonate-water solutions was developed. The model consists of two validated sub-models purposely integrated, one for the reverse electrodialysis unit and the other for the stripping/absorption regeneration uni…
The Effect of Bark Stripping by Deer (Cervus elaphus L.) on Biometric Parameters of the Scots Pine
2022
Bark stripping by red deer (Cervus elaphus L.) is one of the most acute instances of damage wrought by these animals in a forest. Because of its location, bark stripping causes damage to the thickest and most valuable part of the tree trunk, which lowers the quality of the wood due to technical flaws. The research was conducted in 25 sampling sites of pine stands aged 35 years in a mixed, fresh forest habitat in south-western Poland. The study was aimed at assessing the influence of bark damage by deer on biometric parameters of pine stands (Pinus sylvestris L.). The assessment involved the diameter at breast height, height, basal area and volume of the tree stands. The results revealed a s…
Development of a thermodesorption sensor system for the detection of residual solvents in packaging materials
2004
Application specific sensor systems (formerly electronic noses) use static headspace for the volatile generation from condensed phase samples. This extraction method is very simple to implement, but suffers many drawbacks, i.e. in terms of efficiency or sensitivity to partitioning and is very time-consuming. To circumvent these problems, we developed a new method using dynamic extraction of volatiles (stripping). Although this method is known for GC (gas chromatography), the utilization of direct thermal desorption (DTD) in conjunction with gas sensors is quite novel. The unhandy cold trapping step can be avoided by a software integration of the instantaneous volatile concentration over the…