Search results for "structures"

showing 10 items of 4815 documents

Changes in isokinetic torque and muscular activity of elbow flexors muscles with age

2001

This study examined the influence of aging on torque-angular velocity relationships for elbow flexion and the corresponding muscular activity levels in order to target the mechanisms involved in the eccentric muscle action in older adults. Maximal constant angular torque (CAT) at 90 degrees was measured at different angular velocities for concentric (CON; 60, 120, 180, 240 degrees s(-1)), isometric (ISO) and eccentric (ECC; -60, -120 degrees s(-1)) elbow flexor muscle actions in older (OG; 6 females and 4 males, 64-82 years) and young adult subjects (YG; 6 females, 6 males, 19-24 years) on an isokinetic dynamometer. Myoelectrical activity was quantified on biceps and triceps muscles, using …

AdultMaleAginggenetic structuresElbowIsometric exerciseElectromyographyConcentricBiochemistryBicepsEndocrinologyMuscle actionElbowGeneticsHumansMedicineEccentricMuscle SkeletalMolecular BiologyAgedAged 80 and overmedicine.diagnostic_testElectromyographybusiness.industryCell BiologyAnatomyMiddle Agedmedicine.anatomical_structureTorqueFemaleIsokinetic torquebusinessExperimental Gerontology
researchProduct

The development of involuntary and voluntary attention from childhood to adulthood: A combined behavioral and event-related potential study

2006

Abstract Objective This study investigated auditory involuntary and voluntary attention in children aged 6–8, 10–12 and young adults. The strength of distracting stimuli (20% and 5% pitch changes) and the amount of allocation of attention were varied. Methods In an auditory distraction paradigm event-related potentials (ERPs) and behavioral data were measured from subjects either performing a sound duration discrimination task or watching a silent video. Results Pitch changed sounds caused prolonged reaction times and decreased hit rates in all age groups. Larger distractors (20%) caused stronger distraction in children, but not in adults. The amplitudes of mismatch negativity (MMN), P3a, a…

AdultMaleAginggenetic structuresMismatch negativityElectroencephalographybehavioral disciplines and activitiesDevelopmental psychologyP3aEvent-related potentialPhysiology (medical)DistractionmedicineHumansAttentionYoung adultChildBehaviormedicine.diagnostic_testBrainElectroencephalographyhumanitiesSensory SystemsAcoustic StimulationNeurologyTurnoverEvoked Potentials AuditoryFemaleNeurology (clinical)Auditory PhysiologyPsychologyPsychomotor Performancepsychological phenomena and processesClinical Neurophysiology
researchProduct

Affective modulation of conditioned eyeblinks

2009

Affective states are known to modulate reflexive actions. Aversive states potentiate defensive reflexes while appetitive states diminish them. The present study examined whether the same holds for associatively learned defensive eyeblinks to mild, initially neutral auditory stimuli. First, delay eyeblink conditioning was applied to human participants while they viewed emotionally neutral images. Next, the conditioned eyeblink responses (CRs) of the participants were tested during the viewing of unpleasant, neutral, or pleasant images. The most vigorous CRs were found during the unpleasant images, although they did not differ between neutral and pleasant images. The results add to the motiva…

AdultMaleAnalysis of VarianceBlinkinggenetic structuresElectromyographyGeneral NeuroscienceConditioning ClassicalAffective modulationAffectYoung AdultNeuropsychology and Physiological PsychologyAcoustic StimulationEyeblink conditioningReaction TimeAuditory stimuliHumansFemalePsychologyPriming (psychology)Photic StimulationPsychoacousticsCognitive psychologyBiological Psychology
researchProduct

Effects of Spatial Frequency Similarity and Dissimilarity on Contour Integration.

2015

We examined the effects of spatial frequency similarity and dissimilarity on human contour integration under various conditions of uncertainty. Participants performed a temporal 2AFC contour detection task. Spatial frequency jitter up to 3.0 octaves was applied either to background elements, or to contour and background elements, or to none of both. Results converge on four major findings. (1) Contours defined by spatial frequency similarity alone are only scarcely visible, suggesting the absence of specialized cortical routines for shape detection based on spatial frequency similarity. (2) When orientation collinearity and spatial frequency similarity are combined along a contour, performa…

AdultMaleAnalysis of VariancePsychometricsgenetic structureslcsh:Rlcsh:MedicineForm PerceptionYoung AdultPattern Recognition Visual150 PsychologieHumansFemalelcsh:QCues150 Psychologylcsh:SciencePhotic StimulationResearch ArticlePLoS ONE
researchProduct

Goldmann Applanation Tonometry Using Sterile Disposable Silicone Tonometer Shields

1996

Abstract Purpose: Placement of a sterile single-use cover over the tonometer tip may be a convenient and safe alternative method to repeated chemical disinfection. This study was undertaken to evaluate the accuracy and performance of Goldmann applanation tonometry using a sterile disposable silicone tonometer shield over the biprism tip. Methods: The same investigator measured intraocular pressure in 120 eyes with and without the shield. The eyes were tested randomly first with either the uncovered or the covered tonometer to control for the possible effects of repeated tonometry influencing measurement differences. Readings were recorded independently in a masked fashion. Results: The intr…

AdultMaleApplanation tonometryIntraocular pressuremedicine.medical_specialtyAdolescentgenetic structuresSiliconesOcular hypertensionGlaucomaSensitivity and SpecificityGoldmann applanation tonometryChemical disinfectionTonometry Ocularchemistry.chemical_compoundSiliconeDouble-Blind MethodOphthalmologymedicineHumansChildDisposable EquipmentIntraocular PressureAgedAged 80 and overAlternative methodsbusiness.industryReproducibility of ResultsGlaucomaMiddle Agedmedicine.diseaseeye diseasesSurgeryOphthalmologychemistryEvaluation Studies as TopicInfertilityFemaleOcular Hypertensionsense organsbusinessOphthalmology
researchProduct

Comparison of Dynamic Contour Tonometry and Goldmann Applanation Tonometry in Glaucoma Patients and Healthy Subjects

2006

To investigate the agreement in the measurement of intraocular pressure (IOP) obtained by dynamic contour tonometry PASCAL (DCT-PASCAL) and Goldmann applanation tonometry (GAT) in glaucoma eyes and healthy eyes with different central corneal thickness (CCT).Prospective cross-sectional study.In a randomized order, three consecutive IOP measurements were performed on 197 eyes of 107 subjects by one examiner using both DCT-PASCAL and GAT on all eyes. Furthermore, ultrasonic pachymetry was performed. The Spearman correlation coefficient (r) was determined to compare IOP readings between DCT-PASCAL and GAT. Regression-based Bland and Altman analysis was used to evaluate agreement between the ins…

AdultMaleApplanation tonometryIntraocular pressuremedicine.medical_specialtygenetic structuresEye diseaseVisual AcuityGlaucomaGoldmann applanation tonometryCorneaTonometry OcularOphthalmologyHumansMedicineProspective StudiesIntraocular PressureAgedUltrasonographyAged 80 and overbusiness.industryLimits of agreementHealthy subjectsReproducibility of ResultsGlaucomaMiddle Agedmedicine.diseaseeye diseasesOphthalmologyCross-Sectional StudiesVisual Field TestsFemaleOcular Hypertensionsense organsbusinessAmerican Journal of Ophthalmology
researchProduct

The relationship between central corneal thickness and Goldmann applanation tonometry

2003

The aim of this study was to investigate the relationship between Goldmann applanation tonometry and central corneal thickness in a large sample of healthy eyes.Five hundred eyes of 500 subjects (253 women, 50.6 per cent and 247 men, 49.4 per cent) were analysed in a prospective healthy population study. Mean age of the sample was 31 +/- 8 years. Goldmann applanation tonometry was carried out by one physician. Tonometric values were the mean of three consecutive readings. Subsequently, another physician carried out ultrasonic pachymetry with the DGH 2000 AP ultrasonic pachymeter (DGH Technology Inc, San Diego, USA). Ten measurements were made at the centre of the cornea of each eye. The low…

AdultMaleApplanation tonometrymedicine.medical_specialtyIntraocular pressureAdolescentgenetic structuresGoldmann applanation tonometryCorneaTonometry OcularOphthalmologymedicineHumansProspective StudiesIntraocular PressureAgedAnalysis of Variancebusiness.industryCorneal TopographyMiddle Agedeye diseasesLarge sampleOphthalmologyRegression AnalysisOptometryFemalesense organsbusinessOptometryClinical and Experimental Optometry
researchProduct

Ocular biometric repeatability using a new high-resolution swept-source optical coherence tomographer.

2020

To assess the repeatability of ocular biometric parameters using a high-resolution imaging device.74 healthy right eyes were included in this study. Five-repeated measurements were taken with ANTERION high-resolution swept-source optical coherence tomographer (SS-OCT) to measure: corneal thickness (central and at 2, 4 and 6-mm diameters), aqueous depth (AD), lens thickness (LT), anterior chamber volume (ACV), axial length (AL), and pupil (diameter and position). The intrasubject standard deviation (SWe have not found statistically significant differences between repeated measurements (p  0.05). The mean difference for corneal thickness was between -0.08 and 0.28 μm. For AD and LT was 0.004 …

AdultMaleBiometrygenetic structuresBiometricsComputer scienceAnterior ChamberBiomedical EngineeringHigh resolution030204 cardiovascular system & hematologyEye03 medical and health sciencesYoung Adult0302 clinical medicineOpticsOptical coherence tomographyLens CrystallinemedicineHumansAgedmedicine.diagnostic_testbusiness.industryReproducibility of ResultsPupilGeneral MedicineCoherence (statistics)RepeatabilityMiddle Agedeye diseasesSurgeryFemalesense organsbusiness030217 neurology & neurosurgeryTomography Optical CoherenceExpert review of medical devices
researchProduct

Inhibitory Control for Emotional and Neutral Scenes in Competition: An Eye-Tracking Study in Bipolar Disorder

2017

This study examined the inhibitory control of attention to social scenes in manic, depressive, and euthymic episodes of bipolar disorder (BD). Two scenes were simultaneously presented (happy/threatening/neutral [target] versus control). Participants were asked either to look at the emotional pictures (i.e., attend-to-emotional block) or to avoid looking at the emotional pictures (i.e., attend-to-neutral block) while their eye movements were recorded. The initial orienting (latency and percentage of first fixation) and subsequent attentional engagement (gaze duration) were computed. Manic patients showed a higher percentage of initial fixations on happy scenes than on the other scenes, regar…

AdultMaleBipolar DisorderEye Movementsgenetic structuresBipolar disorderEmotionsHappinessEmotional processingEmotional processing050105 experimental psychology03 medical and health sciences0302 clinical medicineOrientationInhibitory controlmedicineHumansAttention0501 psychology and cognitive sciencesBipolar disorderInhibitory controlGeneral Neuroscience05 social sciencesEye movementMiddle AgedFixation (psychology)medicine.diseaseGazeMood-congruent biasesInhibition PsychologicalNeuropsychology and Physiological PsychologyCase-Control StudiesEye trackingFemalePsychology030217 neurology & neurosurgeryCognitive psychologyBiological Psychology
researchProduct

CATCHING FALLING OBJECTS: THE ROLE OF THE CEREBELLUM IN PROCESSING SENSORY-MOTOR ERRORS THAT MAY INFLUENCE UPDATING OF FEEDFORWARD COMMANDS. AN fMRI …

2011

Import JabRef | WosArea Neurosciences and Neurology; International audience; The human motor system continuously adapts to changes in the environment by comparing differences between the brain's predicted outcome of a certain behavior and the observed outcome. This discrepancy signal triggers a sensory-motor error and it is assumed that the cerebellum is a key structure in updating this error and associated feedforward commands. Using fMRI, the aim of the present study was to determine the main cerebellar structures that are involved in the processing of sensory-motor errors and in updating feedforward commands when simply catching a falling ball without displacement of the hand. Subjects o…

AdultMaleCORTEXREPRESENTATIONgenetic structuresTRANSFORMATIONSMovementSpeech recognitionREACHING MOVEMENTS[ SCCO.PSYC ] Cognitive science/PsychologyImage processingSensory systemBrain mappingMECHANISMS03 medical and health sciences0302 clinical medicineCerebellumMotor systemImage Processing Computer-AssistedHumansADAPTATION030304 developmental biologyARM MOVEMENTSNeuronsBrain Mapping0303 health sciencesCommunicationbusiness.industry[SCCO.NEUR]Cognitive science/NeuroscienceGeneral NeuroscienceFeed forwardGRIPCognitionHUMAN BRAINMagnetic Resonance ImagingFunctional imagingbody regionsnervous system[SCCO.PSYC]Cognitive science/Psychology[ SCCO.NEUR ] Cognitive science/NeuroscienceBall (bearing)INTERNAL-MODELSbusinessPsychologyhuman activitiesPsychomotor Performance030217 neurology & neurosurgerypsychological phenomena and processes
researchProduct