Search results for "systems"

showing 10 items of 11952 documents

On-eye optical quality of daily disposable contact lenses for different wearing times

2012

Purpose To quantify the optical quality of various daily disposable contact lenses in vivo and to ascertain its variation in terms of wearing time by means of objective non-invasive determination of wavefront patterns. Methods The crx1 adaptive-optics system was used to measure the wavefront aberrations in 15 myopic eyes before and at 2-h intervals after contact lens fitting, over a 12-h wearing period. Seven types of contact lenses having different material, water content and lens design were evaluated in this study: Dailies Total1, Dailies AquaComfort Plus, Proclear 1 Day, 1-Day Acuvue TruEye, 1-Day Acuvue moist, SofLens daily disposable and Clariti 1-Day. The aberration data were analyse…

AdultMalePoint spread functionOptics and PhotonicsCorneal Wavefront AberrationTime Factorsgenetic structuresZernike polynomialsVisual AcuityPupillaw.inventionYoung Adultsymbols.namesakeOpticslawOptical transfer functionAberrometryMyopiaHumansDisposable EquipmentMathematicsWavefrontbusiness.industryAberrometryContact Lenses Hydrophiliceye diseasesSensory SystemsLens (optics)OphthalmologysymbolsFemalesense organsSpatial frequencybusinessOptometryOphthalmic and Physiological Optics
researchProduct

Factor analysis and reliability of the Movement Imagery Questionnaire.

1994

The purpose of this work was to analyze the factor structure, estimate reliability of the Movement Imagery Questionnaire of Hall and Pongrac, and examine differences between men and women on factor scores. The results for 63 men and 47 women supported the bifactorial structure and reliability of this self-report and its adequacy in comparisons of visual and kinesthetic imagery scores.

AdultMalePsychometricsAdolescentPersonality InventoryPsychometricsMotion PerceptionExperimental and Cognitive PsychologyTest validity050105 experimental psychologyDevelopmental psychologyFactor (chord)03 medical and health sciences0302 clinical medicineOrientationHumans0501 psychology and cognitive sciencesKinesthesisMovement (music)05 social sciencesKinesthetic learningReproducibility of ResultsBody movementCognition030229 sport sciencesSensory SystemsImaginationFemalePsychologyFactor Analysis StatisticalClinical psychologyMental imagePerceptual and motor skills
researchProduct

Reduced oscillatory gamma-band responses in unmedicated schizophrenic patients indicate impaired frontal network processing

2004

Abstract Objective Integration of sensory information by cortical network binding appears to be crucially involved in target detection. Studies in schizophrenia using functional and diffusion tensor neuroimaging, event-related potentials and EEG coherence indicate an impairment of cortical network coupling in this disorder. Previous electrophysiological investigations in animals and humans suggested that gamma activity (oscillations at around 40 Hz) is essential for cortical network binding. Studies in medicated schizophrenia provide evidence for a reduced gamma activity in the context of auditory stimulus processing. This is the first investigation of oscillatory activations in the gamma-b…

AdultMalePsychosisAdolescentSensory systemStimulus (physiology)ElectroencephalographyAuditory cortexNeuroimagingEvent-related potentialPhysiology (medical)Reaction TimemedicineHumansAnalysis of Variancemedicine.diagnostic_testElectroencephalographymedicine.diseaseSensory SystemsFrontal LobeAcoustic StimulationNeurologyFrontal lobeSchizophreniaFemaleNeurology (clinical)Nerve NetPsychologyNeuroscienceClinical Neurophysiology
researchProduct

Bloating is associated with worse quality of life, treatment satisfaction, and treatment responsiveness among patients with constipation-predominant …

2016

Background The management of bloating is unclear and its relationship with patients' well-being and treatment satisfaction independent of other abdominal symptoms is uncharacterized. We evaluated the association of bloating with patient-reported outcomes. Methods Thirty-nine centers for functional gastrointestinal disorders joined the laxative inadequate relief survey. We enrolled 2203 consecutive outpatients with functional constipation (FC) or constipation-predominant irritable bowel syndrome (IBS-C) in two cross-sectional waves. Both wave 1 and 2 included the SF-12, the patient assessment of constipation-symptoms (PAC-SYM), and the treatment satisfaction questionnaire for medication (TSQ…

AdultMaleQuality of lifemedicine.medical_specialtyConstipationCross-sectional studyPhysiologyBloating; Chronic constipation; Functional constipation; Irritable bowel syndrome; Patient-reported outcomes; Quality of life; Treatment satisfaction; Physiology; Endocrine and Autonomic Systems; GastroenterologyBloating; Chronic constipation; Functional constipation; Irritable bowel syndrome; Patient-reported outcomes; Quality of life; Treatment satisfaction; Adult; Constipation; Cross-Sectional Studies; Female; Flatulence; Humans; Irritable Bowel Syndrome; Male; Middle Aged; Prevalence; Quality of Life; Surveys and QuestionnairesEndocrine and Autonomic System03 medical and health sciences0302 clinical medicineBloatingQuality of lifeSurveys and QuestionnairesInternal medicinePrevalencemedicineFlatulenceHumansIrritable bowel syndromePatient-reported outcomeChronic constipationSettore MED/12 - GastroenterologiaPatient-reported outcomesTreatment satisfactionBloating; Chronic constipation; Functional constipation; Irritable bowel syndrome; Patient-reported outcomes; Quality of life; Treatment satisfaction; Adult; Constipation; Cross-Sectional Studies; Female; Flatulence; Humans; Irritable Bowel Syndrome; Male; Middle Aged; Prevalence; Quality of Life; Surveys and Questionnaires; Physiology; Endocrine and Autonomic Systems; GastroenterologyEndocrine and Autonomic Systemsbusiness.industryChronic constipationBloatingSettore MED/09 - MEDICINA INTERNAGastroenterologyMiddle Agedmedicine.diseaseIrritable bowel syndromeSettore MED/18 - Chirurgia GeneraleCross-Sectional StudiesTolerability030220 oncology & carcinogenesisPhysical therapyFunctional constipationFemale030211 gastroenterology & hepatologymedicine.symptombusinessConstipationFunctional constipation
researchProduct

Influence of articulation rate on two memory tasks in young and older adults.

2008

This study investigated the relation between phonological loop functioning and age. Phonological loop is a time-based subsystem of the Working Memory Model of Baddeley and Wilson, which uses rehearsal of information as an active process to avoid phonological decay. Performance differences were examined between young and older adults in two speech-based memory tasks, such as the immediate serial recall of words and the Digit Ordering Task. Analysis showed that performance on both tasks was lower for the older group. Articulation rate was also measured to test the hypothesis that the impairment of some cognitive functions in adults can be associated to their slowness or the greater time need…

AdultMaleRecallProcess (engineering)Age FactorsExperimental and Cognitive PsychologyCognitionMiddle AgedSensory SystemsNumerical digitTask (computing)Speech Production MeasurementMemoryMental RecallHumansSpeechFemaleBaddeley's model of working memoryArticulation (phonetics)SlownessPsychologyCognitive psychologyPerceptual and motor skills
researchProduct

An alternative clinical routine for subjective refraction based on power vectors with trial frames.

2016

PURPOSE Subjective refraction determines the final point of refractive error assessment in most clinical environments and its foundations have remained unchanged for decades. The purpose of this paper is to compare the results obtained when monocular subjective refraction is assessed in trial frames by a new clinical procedure based on a pure power vector interpretation with conventional clinical refraction procedures. METHODS An alternative clinical routine is described that uses power vector interpretation with implementation in trial frames. Refractive error is determined in terms of: (i) the spherical equivalent (M component), and (ii) a pair of Jackson Crossed Cylinder lenses oriented …

AdultMaleRefractive errorCorrelation coefficientAdolescentVisual AcuityAstigmatismRefraction Ocular01 natural sciences010309 optics03 medical and health sciencesYoung Adult0302 clinical medicineOptics0103 physical sciencesmedicineHumansPhoropterMathematicsMonocularbusiness.industryOrientation (computer vision)Vision TestsEquipment Designmedicine.diseaseRefractive ErrorsSubjective refractionRefractionSensory SystemsOphthalmologyEyeglasses030221 ophthalmology & optometryFemalebusinessAlgorithmOptometryOphthalmicphysiological optics : the journal of the British College of Ophthalmic Opticians (Optometrists)
researchProduct

Postoperative astigmatism and rotational stability after Artisan toric phakic intraocular lens implantation

2003

Abstract Purpose To evaluate deviations in the axis (intended versus achieved) and postoperative astigmatism after implantation of an Artisan toric phakic intraocular lens (IOL). Setting University Eye Hospital, Mainz, Germany. Methods This prospective study comprised 29 eyes with high ametropia and astigmatism. All eyes had uneventful implantation of a toric phakic IOL through a superior scleral tunnel incision at 12 o’clock. After a minimum of 6 months, the uncorrected visual acuity (UCVA), best correct visual acuity, refraction, and astigmatism were analyzed in all eyes. A multivariate analysis of postoperative astigmatism was performed. Results After a follow-up of at least 6 months, 95…

AdultMaleRefractive errorVisual acuityRotationgenetic structuresmedicine.medical_treatmentEmmetropiaIntraocular lensPhakic intraocular lensLens Implantation IntraocularmedicineHumansPostoperative PeriodProspective StudiesDioptreLenses Intraocularbusiness.industryAstigmatismEquipment DesignMiddle AgedRefractive Errorsmedicine.diseaseeye diseasesSensory SystemsRefractive Surgical ProceduresToric lensOphthalmologyMeridian (perimetry visual field)OptometryFemaleSurgerysense organsmedicine.symptombusinessJournal of Cataract and Refractive Surgery
researchProduct

Phakic intraocular lenses to correct high myopia

2003

Abstract Purpose: To evaluate the feasibility and safety of using phakic intraocular lenses (IOLs) to correct high myopia by comparing 3 IOL models: Adatomed, Staar, and Artisan. Setting: La Fe University Hospital, Department of Ophthalmology, and the Fundacion Oftalmologica del Mediterraneo, Valencia, Spain. Methods: In this prospective comparative study, a phakic IOL was implanted in 217 highly myopic eyes (118 patients). Fifty-nine eyes received an Adatomed IOL, 21 eyes a Staar IOL, and 137 eyes an Artisan IOL. The mean preoperative spherical equivalent was −15.39 diopters (D) ± 2.83 (SD), −16.00 ± 5.05 D, and −16.17 ± 2.75 D in the Adatomed, Staar, and Artisan groups, respectively. The …

AdultMaleRefractive errormedicine.medical_specialtyIntraocular pressureAnterior subcapsular cataractVisual acuitygenetic structuresAnterior ChamberEye diseasemedicine.medical_treatmentVisual AcuityIntraocular lensRefraction OcularPhakic intraocular lensCataractPostoperative ComplicationsLens Implantation IntraocularOphthalmologyLens CrystallineMyopiamedicineHumansProspective StudiesIntraocular PressureDioptreLenses Intraocularbusiness.industryMiddle Agedmedicine.diseaseeye diseasesSensory SystemsOphthalmologyFeasibility StudiesFemaleSurgerysense organsSafetymedicine.symptombusinessFollow-Up StudiesJournal of Cataract & Refractive Surgery
researchProduct

Long-term results of surgical treatment of high myopia with Worst-Fechner intraocular lenses

1995

Abstract This retrospective study evaluated the results in 90 eyes that had a minus-power anterior chamber intraocular lens implanted to correct high myopia. Preoperative myopia ranged from −7.00 to −24.00 D. Postoperative spherical equivalent was −0.50 D; 80.5% of eyes were within 1.00 D of emmetropia. Two years postoperatively, no cataract formation, retinal detachment, glaucoma, or significant endothelial damage had occurred. We conclude that minus-power lenses can rapidly, safely, and predictably correct high myopia in phakic patients.

AdultMaleRefractive errormedicine.medical_specialtygenetic structuresAnterior ChamberEye diseasemedicine.medical_treatmentVisual AcuityEmmetropiaGlaucomaIntraocular lensProsthesis DesignVision disorderPostoperative ComplicationsOphthalmologyMyopiamedicineHumansLongitudinal StudiesAgedRetrospective StudiesLenses Intraocularbusiness.industryRetinal detachmentRetrospective cohort studyMiddle AgedPrognosismedicine.diseaseeye diseasesSensory SystemsOphthalmologyFemaleSurgerysense organsmedicine.symptombusinessFollow-Up StudiesJournal of Cataract and Refractive Surgery
researchProduct

Excimer laser photorefractive keratectomy for high myopia

1995

Abstract One hundred and thirty-three eyes of 103 patients had photorefractive keratectomy with a slit scan mode excimer laser for myopia ranging from −6.00 to −22.00 diopters (D). The epithelium was removed with 20% ethanol, and the ablation was done with a tapered profile surrounding the optical zone. Patients were divided into two groups based on preoperative myopia: Group A, −6.00 D to −12.00 D (88 eyes); Group B, −12.50 D to −22.00 D (45 eyes). In Group A, mean preoperative refraction was −9.59 ± 1.79 D. Mean postoperative refraction was −0.29 ± 1.47 D at one month, −0.85 ± 1.68 D at three months, −1.17 ± 2.04 D at six months, and −0.56 ± 0.74 D at one year. Anterior stromal haze was g…

AdultMaleRefractive errormedicine.medical_specialtygenetic structuresCorneal Stromamedicine.medical_treatmentEye diseaseVisual AcuityRefraction OcularExcimerPhotorefractive KeratectomyEpitheliumCorneaVision disorderCorneal OpacityOphthalmologyMyopiamedicineHumansIntraocular PressureDioptreExcimer laserbusiness.industryMiddle AgedPrognosismedicine.diseaseAblationeye diseasesSensory SystemsPhotorefractive keratectomyOphthalmologyFemaleLasers ExcimerSurgerysense organsmedicine.symptombusinessJournal of Cataract and Refractive Surgery
researchProduct