Search results for "ta217"
showing 10 items of 28 documents
Multi-subject fMRI analysis via combined independent component analysis and shift-invariant canonical polyadic decomposition
2014
Canonical polyadic decomposition (CPD) may face a local optimal problem when analyzing multi-subject fMRI data with inter-subject variability. Beckmann and Smith proposed a tensor PICA approach that incorporated an independence constraint to the spatial modality by combining CPD with ICA, and alleviated the problem of inter-subject spatial map (SM) variability.This study extends tensor PICA to incorporate additional inter-subject time course (TC) variability and to connect CPD and ICA in a new way. Assuming multiple subjects share common TCs but with different time delays, we accommodate subject-dependent TC delays into the CP model based on the idea of shift-invariant CP (SCP). We use ICA …
Cognitive control in auditory working memory is enhanced in musicians
2010
Musical competence may confer cognitive advantages that extend beyond processing of familiar musical sounds. Behavioural evidence indicates a general enhancement of both working memory and attention in musicians. It is possible that musicians, due to their training, are better able to maintain focus on task-relevant stimuli, a skill which is crucial to working memory. We measured the blood oxygenation-level dependent (BOLD) activation signal in musicians and non-musicians during working memory of musical sounds to determine the relation among performance, musical competence and generally enhanced cognition. All participants easily distinguished the stimuli. We tested the hypothesis that mus…
Validating rationale of group-level component analysis based on estimating number of sources in EEG through model order selection
2012
This study addresses how to validate the rationale of group component analysis (CA) for blind source separation through estimating the number of sources in each individual EEG dataset via model order selection. Control children, typically reading children with risk for reading disability (RD), and children with RD participated in the experiment. Passive oddball paradigm was used for eliciting mismatch negativity during EEG data collection. Data were cleaned by two digital filters with pass bands of 1-30 Hz and 1-15 Hz and a wavelet filter with the pass band narrower than 1-12 Hz. Three model order selection methods were used to estimate the number of sources in each filtered EEG dataset. Un…
Hemodynamic responses to speech and music in newborn infants
2009
We used near‐infrared spectroscopy (NIRS) to study responses to speech and music on the auditory cortices of 13 healthy full‐term newborn infants during natural sleep. The purpose of the study was to investigate the lateralization of speech and music responses at this stage of development. NIRS data was recorded from eight positions on both hemispheres simultaneously with electroencephalography, electrooculography, electrocardiography, pulse oximetry, and inclinometry. In 11 subjects, statistically significant (P < 0.02) oxygenated (HbO(2)) and total hemoglobin (HbT) responses were recorded. Both stimulus types elicited significant HbO(2) and HbT responses on both hemispheres in five subjec…
Coded excitation speeds up the detection of the fundamental flexural guided wave in coated tubes
2016
The fundamental flexural guided wave (FFGW) permits ultrasonic assessment of the wall thickness of solid waveguides, such as tubes or, e.g., long cortical bones. Recently, an optical non-contact method was proposed for ultrasound excitation and detection with the aim of facilitating the FFGW reception by suppressing the interfering modes from the soft coating. This technique suffers from low SNR and requires iterative physical scanning across the source-receiver distance for 2D-FFT analysis. This means that SNR improvement achieved by temporal averaging becomes time-consuming (several minutes) which reduces the applicability of the technique, especially in time-critical applications such as…
Bioactive glass ions as strong enhancers of osteogenic differentiation in human adipose stem cells.
2015
Bioactive glasses are known for their ability to induce osteogenic differentiation of stem cells. To elucidate the mechanism of the osteoinductivity in more detail, we studied whether ionic extracts prepared from a commercial glass S53P4 and from three experimental glasses (2-06, 1-06 and 3-06) are alone sufficient to induce osteogenic differentiation of human adipose stem cells. Cells were cultured using basic medium or osteogenic medium as extract basis. Our results indicate that cells stay viable in all the glass extracts for the whole culturing period, 14 days. At 14 days the mineralization in osteogenic medium extracts was excessive compared to the control. Parallel to the increased mi…
Adaptive independent vector analysis for multi-subject complex-valued fMRI data.
2017
Abstract Background Complex-valued fMRI data can provide additional insights beyond magnitude-only data. However, independent vector analysis (IVA), which has exhibited great potential for group analysis of magnitude-only fMRI data, has rarely been applied to complex-valued fMRI data. The main challenges in this application include the extremely noisy nature and large variability of the source component vector (SCV) distribution. New method To address these challenges, we propose an adaptive fixed-point IVA algorithm for analyzing multiple-subject complex-valued fMRI data. We exploited a multivariate generalized Gaussian distribution (MGGD)- based nonlinear function to match varying SCV dis…
MeV ion beam lithography of biocompatible halogenated Parylenes using aperture masks
2015
Parylenes are poly(p-xylylene) polymers that are widely used as moisture barriers and in biomedicine because of their good biocompatibility. We have investigated MeV ion beam lithography using 16O+ ions for writing defined patterns in Parylene-C, which is evaluated as a coating material for the Cochlear Implant (CI) electrode array, a neuroprosthesis to treat some forms of deafness. Parylene-C and -F on silicon and glass substrates as well as 50 μm thick PTFE were irradiated to different fluences (1×1013-1×10161×1013-1×1016 1 MeV 16O+ ions cm−2) through aperture masks under high vacuum and a low pressure (<10−3 mbar) oxygen atmosphere. Biocompatibility of the irradiated and unirradiated …
Study of Proton and 3He Induced Reactions on 235U at Low Energies
2014
Abstract Highly enriched 235 U targets were irradiated with 6.5 − 16.1 MeV protons and 20.4 − 42.0 MeV 3 He ions. The irradiated targets were measured with γ and α spectrometric methods to identify and quantify the produced reaction products. After primary activity measurements the targets were dissolved, and interesting Pu and Np reaction products were chemically separated from the target material, and measured for activity again. From the activity results it was possible to calculate the reaction cross sections for differently produced nuclides. The data obtained from the experiment resulted in earlier unknown excitation functions on proton and 3 He induced nuclear reactions on 235 U.
Neutron generator for BNCT based on high current ECR ion source with gyrotron plasma heating
2015
BNCT development nowadays is constrained by a progress in neutron sources design. Creation of a cheap and compact intense neutron source would significantly simplify trial treatments avoiding use of expensive and complicated nuclear reactors and accelerators. D-D or D-T neutron generator is one of alternative types of such sources for. A so-called high current quasi-gasdynamic ECR ion source with plasma heating by millimeter wave gyrotron radiation is suggested to be used in a scheme of D-D neutron generator in the present work. Ion source of that type was developed in the Institute of Applied Physics of Russian Academy of Sciences (Nizhny Novgorod, Russia). It can produce deuteron ion beam…