XUV diagnostic to monitor H-like emission from B, C, N, and O for the W7-X stellarator
2019
The “C/O Monitor” system for the Wendelstein 7-X (W7-X) stellarator is a dedicated spectrometer with high throughput and high time resolution (order of 1 ms) for fast monitoring of content of low-Z impurities in the plasma. The observed spectral lines are fixed to Lyman-α lines of H-like atoms of carbon (3.4 nm), oxygen (1.9 nm), nitrogen (2.5 nm), and boron (4.9 nm). The quality of the wall condition will be monitored by the measurements of oxygen being released from the walls during the experiments. The strong presence of carbon is an indication for enhanced plasma-wall interaction or overload of plasma facing components. The presence of nitrogen (together with oxygen) may indicate a poss…
Choice of the detectors for light impurities plasma studies at W7-X using ‘CO Monitor’ system
2019
Abstarct The ‘CO Monitor’ is a new spectrometer system dedicated for the continuous measurements of line intensities of carbon, oxygen, boron and nitrogen at the fusion plasma experiment Wendelstein 7-X (W7-X). Its main purpose is to deliver constant information about indicated elements with high time resolution (better than 1 ms), but low spatial resolution since the line shapes are not going to be investigated. The system consists of four independent channels, each equipped with dispersive element dedicated for measurement of selected line of interest. In order to perform the highest efficiency of the ‘CO Monitor’ system, it is essential to choose the proper detector type for this task. T…
Major results from the first plasma campaign of the Wendelstein 7-X stellarator
2017
After completing the main construction phase of Wendelstein 7-X (W7-X) and successfully commissioning the device, first plasma operation started at the end of 2015. Integral commissioning of plasma start-up and operation using electron cyclotron resonance heating (ECRH) and an extensive set of plasma diagnostics have been completed, allowing initial physics studies during the first operational campaign. Both in helium and hydrogen, plasma breakdown was easily achieved. Gaining experience with plasma vessel conditioning, discharge lengths could be extended gradually. Eventually, discharges lasted up to 6 s, reaching an injected energy of 4 MJ, which is twice the limit originally agreed for t…
Tracer-Encapsulated Solid Pellet (TESPEL) injection system for the TJ-II stellarator
2016
A tracer-encapsulated solid pellet (TESPEL) injection system for the TJ-II stellarator was recently developed. In order to reduce the time and cost for the development, we combined a TESPEL injector provided by National Institute for Fusion Science with an existing TJ-II cryogenic pellet injection system. Consequently, the TESPEL injection into the TJ-II plasma was successfully achieved, which was confirmed by several pellet diagnostics including a normal-incidence spectrometer for monitoring a tracer impurity behavior.
The hydraulic behaviour of the simulacrum of a Plasma Vessel Module of the W 7-X Reactor
2007
Technical challenges in the construction of the steady-state stellarator Wendelstein 7-X
2013
The next step in the Wendelstein stellarator line is the large superconducting device Wendelstein 7-X, currently under construction in Greifswald, Germany. Steady-state operation is an intrinsic feature of stellarators, and one key element of the Wendelstein 7-X mission is to demonstrate steady-state operation under plasma conditions relevant for a fusion power plant. Steady-state operation of a fusion device, on the one hand, requires the implementation of special technologies, giving rise to technical challenges during the design, fabrication and assembly of such a device. On the other hand, also the physics development of steady-state operation at high plasma performance poses a challeng…
Confinement in Wendelstein 7-X limiter plasmas
2017
Observations on confinement in the first experimental campaign on the optimized Stellarator Wendelstein 7-X are summarized. In this phase W7-X was equipped with five inboard limiters only and thus the discharge length restricted to avoid local overheating. Stationary plasmas are limited to low densities <2–3 · 1019 m−3. With the available 4.3 MW ECR Heating core Te ~ 8 keV, Ti ~ 1–2 keV are achieved routinely resulting in energy confinement time τE between 80 ms to 150 ms. For these conditions the plasmas show characteristics of core electron root confinement with peaked Te-profiles and positive Er up to about half of the minor radius. Profiles and plasma currents respond to on- and off-axi…
Magnetic configuration effects on the Wendelstein 7-X stellarator
2018
The two leading concepts for confining high-temperature fusion plasmas are the tokamak and the stellarator. Tokamaks are rotationally symmetric and use a large plasma current to achieve confinement, whereas stellarators are non-axisymmetric and employ three-dimensionally shaped magnetic field coils to twist the field and confine the plasma. As a result, the magnetic field of a stellarator needs to be carefully designed to minimize the collisional transport arising from poorly confined particle orbits, which would otherwise cause excessive power losses at high plasma temperatures. In addition, this type of transport leads to the appearance of a net toroidal plasma current, the so-called boot…
Overview of diagnostic performance and results for the first operation phase in Wendelstein 7-X (invited)
2016
Wendelstein 7-X, a superconducting optimized stellarator built in Greifswald/Germany, started its first plasmas with the last closed flux surface (LCFS) defined by 5 uncooled graphite limiters in December 2015. At the end of the 10 weeks long experimental campaign (OP1.1) more than 20 independent diagnostic systems were in operation, allowing detailed studies of many interesting plasma phenomena. For example, fast neutral gas manometers supported by video cameras (including one fast-frame camera with frame rates of tens of kHz) as well as visible cameras with different interference filters, with field of views covering all ten half-modules of the stellarator, discovered a MARFE-like radiati…
Effect of spatial distribution of impurity ions on the signal of ‘C/O monitor for Wendelstein 7-X’ - an indicator of plasma wall interactions
2022
The ‘C/O monitor’ is a dedicated diagnostic system designed to monitor light impurities (B, C, N and O) in the Wendelstein 7-X (W7-X) stellarator. Its main goal is to provide fast (∼1 ms) information about the impurity level which is measured from a large plasma volume (high throughput). Its first subsystem dedicated to measure Lyman-α lines of H-like carbon (C5+ − 3.4 nm – used as PFC material) and oxygen (O7+ − 1.9 nm – common impurity absorbed by inner vessels’ walls) is going to be commissioned during the next Operational Phase of W7-X. Since the radiated photon intensity of a given impurity depends strongly on plasma kinetic parameters (Te, ne) and impurity transport, it is important t…