Search results for "testing."
showing 10 items of 1654 documents
Improved global-local model to predict guided-wave scattering patterns from discontinuities in complex parts
2019
Ultrasonic guided-wave testing can greatly benefit from (1) an ability to provide quantitative information on the damage that is being detected, and (2) an ability to select the best mode-frequency combination for maximum sensitivity to a given type of damage. Achieving these capabilities in complex structures (e.g. nonprismatic structures such as a stiffened panel in aerospace fuselages) is a nontrivial task. This paper will discuss an improved Global-Local (GL) method where the geometrical “local” discontinuity (e.g. the stiffener) is modelled by traditional FE discretization and the rest of the structure (“global” part) is modelled by Semi-Analytical Finite Element (SAFE) cross-sectional…
Coded Excitation of the Fundamental Flexural Guided Wave in Coated Bone Phantoms
2017
There is an increasing interest of using ultrasonic guided waves to assess long cortical bones. In particular, a method of ultrasonic estimation of cortical thickness based on the fundamental flexural guided wave (FFGW), generally consistent with the A0 Lamb mode, has proven to be promising in vitro and modeling studies. Soft-tissue coating on top of the bone makes, however, the related in vivo application challenge. Visibility of FFGW on top of the soft tissue is not good due to the characteristic displacement profile of this mode, and due to its relatively high attenuation in the bone and surrounding tissue. Moreover, the soft tissue provides a direct propagation path for ultrasonic modes…
Obstructing propagation of interfering modes improves detection of guided waves in coated bone models
2014
Interference due to wave propagation in soft tissue that covers the bone is a major challenge to in vivo assessment of the fundamental flexural guided wave (FFGW) in bone. To improve signal-to-interference ratio (SIR) we propose to obstruct the propagation of interfering modes by locally deforming the coating by external mechanical compression. This approach was modeled by 2D finite-element transient domain (FEMTD) simulations in a fluid-coated (7 mm) solid plate (3 mm). The fluid layer mimics the soft tissue that covers the bone. A single emitter or a 6-element phased array excited ultrasound pulses at 50 kHz on the surface of the coating, and a receiver array was placed on the surface, 20…
2D Waveguided Bessel Beam Generated Using Integrated Metasurface-Based Plasmonic Axicon.
2020
International audience; Near-field imaging of the propagation of a diffraction-free Bessel-type beam in a guided wave configuration generated by means of a metasurface-based axicon lens integrated on a silicon waveguide is reported. The operation of the axicon lens with a footprint as small as 11 μm2 is based on local engineering of the effective index of the silicon waveguide with plasmonic nanoresonators. This generic approach, which can be adapted to different types of planar lightwave circuit platforms, offers the possibility to design nano-engineered optical devicesbased on the use of plasmonic resonators to control light at the nanoscale.
Global–local model for three-dimensional guided wave scattering with application to rail flaw detection
2021
This study presents a three-dimensional global–local formulation for the prediction of guided wave scattering from discontinuities (e.g. defects). The approach chosen utilizes the Semi-Analytical Finite Element method for the “global” portion of the waveguide, and a full Finite Element discretization for the “local” portion of the waveguide containing the discontinuity. The application of interest is the study of guided wave scattering from transverse head defects in rails. Theoretical scattering results are impossible to obtain in this case for a wide-frequency range. While three-dimensional Semi-Analytical Finite Element–Finite Element models for guided wave scattering studies have been …
Detection of disbonds in multilayer structures by laser-based ultrasonic technique
2008
Adhesively bonded multi-layer structures are frequently used, mostly in the aerospace industry, for their structural efficiency. Nondestructive evaluation of bond integrity in these types of structures, both after manufacturing and for periodic inspection during service, is extremely important. A laser-based ultrasonic technique has been evaluated for non-contact detection of disbonds in aluminum multi-layer structures. Two configurations have been used to detect disbonded areas: pitch-catch with unidirectional guided wave scan and through-transmission with bidirectional scan. Guided wave scanning was done with a laser line source and air-coupled transducer sensing at 500 kHz, 1 ;MHz, and 2…
Empfindlichkeitsprüfung vonCandidaSpecies unterAnwendung des kommerziellen Agardiffusionsverfahrens mit LD 2-Ringen für die Routinediagnostik
2003
Zusammenfassung: Die steigende Zahl von Pilzinfektionen, die Entwicklung und Einfuhrung neuer antimykotischer Substanzen sowie die Moglichkeit der Resistenzentwicklung unter Therapie mit Antimykotika haben in der Vergangenheit zu einem standig wachsenden Bedarf an standardisierten Verfahren zur Empfindlichkeitstestung von pathogenen Pilzen gefuhrt. Hierbei entstand unter anderem eine Vielzahl kommerzieller Testverfahren, bei denen mit Hilfe vorgefertigter Testkits eine einfache und schnelle Durchfuhrung der Empfindlichkeitsprufung erzielt werden soll. Eine dieser Methoden, welche in manchen Laboratorien in Deutschland angewendet wird, ist das so genannte LD 2 Ring-Verfahren, welches auf dem…
Il consenso informato per l’effettuazione del test per la diagnosi da HIV: come comportarsi in caso di minori.
2008
Informed consent and minors: hiv testing in italian legislation.
2008
Solvent impact on the planarity and aromaticity of free and monohydrated zinc phthalocyanine: a theoretical study
2017
A theoretical investigation on the planarity of molecular structure of zinc phthalocyanine (ZnPc) and its aromaticity has been performed using B3LYP and M06-2X density functionals combined with selected Pople-type basis sets. The effect of the applied calculation method on the optimized structure of ZnPc and ZnPc∙∙∙H2O, both in the gas phase and in the polar solvent, was analyzed. To quantify the aromaticity of the ZnPc and ZnPc∙∙∙H2O complexes, both the geometric and magnetic criteria, i.e., Harmonic Oscillator Model of Aromaticity (HOMA) index and the nucleus-independent chemical shift (NICS) values at the centers or 1 A above the centers of structural subunits, were calculated. The energ…