Search results for "three-dimensional"
showing 10 items of 370 documents
Prevalence of coronary artery intramyocardial course in a large population of clinical patients detected by multislice computed tomography coronary a…
2008
Background: Intramyocardial course, an inborn coronary anomaly, is defined as a segment of a major epicardial coronary artery that runs intramurally through the myocardium; in particular, we distinguish myocardial bridging, in which the vessel returns to an epicardial position after the muscle bridge, and intramyocardial course, which is described as a vessel running and ending in the myocardium. Purpose: To evaluate the prevalence of myocardial bridging and intramyocardial course of coronary arteries as defined by multidetector computed tomography (MDCT) angiography. Material and Methods: The study population consisted of 242 consecutive patients (211 men, 31 women; mean age 59±6 years) w…
Workflow-centred open-source fully automated lung volumetry in chest CT
2019
Aim To develop a robust open-source method for fully automated extraction of total lung capacity (TLC) from computed tomography (CT) images and to demonstrate its integration into the clinical workflow. Materials and methods Using only open-source software, an algorithm was developed based on a region-growing method that does not require manual interaction. Lung volumes calculated from reconstructions with different kernels (TLCCT) were assessed. To validate the algorithm calculations, the results were correlated to TLC measured by pulmonary function testing (TLCPFT) in a subgroup of patients for which this information was available within 3 days of the CT examination. Results A total of 28…
Factors influencing transfer accuracy of cone beam CT-derived template-based implant placement.
2011
Objectives The aim of the present investigation was the analysis of the factors presumptively affecting the accuracy outcome of cone-beam computed tomography (CBCT)-derived laboratory-based surgical guides for implant placement in partially edentulous patients. Materials and methods In 52 partially edentulous patients a total of 132 implants were placed following CBCT diagnostics with the aid of laboratory-fabricated, tooth-borne templates. Based on the image fusion technique measurements were done to calculate linear and angular deviations between virtually planned and placed implants. The implant sites were stratified according to four factors that presumably may influence the transfer ac…
Quantification of epicardial adipose tissue in coronary calcium score and CT coronary angiography image data sets: comparison of attenuation values, …
2016
The aim of the study was to compare epicardial adipose tissue (EAT) characteristics assessed with coronary calcium score (CS) and CT coronary angiography (CTCA) image data sets.In 76 patients (mean age 59 ± 13 years) who underwent CS and CTCA owing to suspected coronary artery disease (CAD), EAT was quantified in terms of density (Hounsfield units), thickness and volume. The EAT volume was extracted with a semi-automatic software.A moderate correlation was found between EAT density in CS and CTCA image data sets (-100 ± 19 HU vs -70 ± 24 HU; p 0.05, r = 0.55). The distribution of EAT was not symmetrical with a maximal thickness at the right atrioventricular groove (14.2 ± 5.3 mm in CS, 15.…
Deep seroma after incisional hernia repair. Case reports and review of the literature.
2015
Wound-related complications are common after incisional hernia repair with mesh; seroma formation is the most frequent problem. The formation of a deep seroma has been rarely reported in the literature.In one year, September 2012-2013, 136 patients underwent surgery for incisional hernia repair, both elective and urgent.The following complications were observed: one dislocation of polypropylene prosthesis, a massive relapsed seroma and two deep seromas described in this article. A 63- years-old female underwent open incisional hernia repair with an intraperitoneal PTFE patch. She developed recurrent seroma under the mesh drained percutaneously, and finally the prosthesis was removed. A 72- …
Training labels for hippocampal segmentation based on the EADC-ADNI harmonized hippocampal protocol
2015
Abstract Background The European Alzheimer's Disease Consortium and Alzheimer's Disease Neuroimaging Initiative (ADNI) Harmonized Protocol (HarP) is a Delphi definition of manual hippocampal segmentation from magnetic resonance imaging (MRI) that can be used as the standard of truth to train new tracers, and to validate automated segmentation algorithms. Training requires large and representative data sets of segmented hippocampi. This work aims to produce a set of HarP labels for the proper training and certification of tracers and algorithms. Methods Sixty-eight 1.5 T and 67 3 T volumetric structural ADNI scans from different subjects, balanced by age, medial temporal atrophy, and scanner…
Assessment of Susceptibility Risk Factors for ADHD in Imaging Genetic Studies
2019
Objective: ADHD consists of a count of symptoms that often presents heterogeneity due to overdispersion and excess of zeros. Statistical inference is usually based on a dichotomous outcome that is underpowered. The main goal of this study was to determine a suited probability distribution to analyze ADHD symptoms in Imaging Genetic studies. Method: We used two independent population samples of children to evaluate the consistency of the standard probability distributions based on count data for describing ADHD symptoms. Results: We showed that the zero-inflated negative binomial (ZINB) distribution provided the best power for modeling ADHD symptoms. ZINB reveals a genetic variant, rs273342…
Harmonized benchmark labels of the hippocampus on magnetic resonance: The EADC-ADNI project
2015
Abstract Background A globally harmonized protocol (HarP) for manual hippocampal segmentation based on magnetic resonance has been recently developed by a task force from European Alzheimer's Disease Consortium (EADC) and Alzheimer's Disease Neuroimaging Initiative (ADNI). Our aim was to produce benchmark labels based on the HarP for manual segmentation. Methods Five experts of manual hippocampal segmentation underwent specific training on the HarP and segmented 40 right and left hippocampi from 10 ADNI subjects on both 1.5 T and 3 T scans. An independent expert visually checked segmentations for compliance with the HarP. Descriptive measures of agreement between tracers were intraclass cor…
Test-retest reliability of 3D kinematic gait variables in hip osteoarthritis patients
2011
Import JabRef | WosArea Orthopedics; Rheumatology; International audience; Objectives: (1) to investigate the test-retest reliability of 3D gait analysis (3DGA) in hip Osteoarthritis (OA) patients; (2) to find the minimum number of gait trials needed to overcome intrinsic variability; (3) to check the accuracy of angles measured by the 3D system. Design: 23 Patients suffering from hip OA with no other major disease were recruited. We evaluated the reliability of spatio-temporal variables and body angles (lower-limb joints, trunk and pelvis angles) during two sessions of 3DGA using intra-class correlation coefficients (ICC). The minimum number of trials needed to overcome intrinsic variabili…
Pentafecta Rates of Three-Dimensional Laparoscopic Radical Prostatectomy: Our Experience after 150 Cases
2017
Introduction Three-dimensional (3D) laparoscopy with a flexible camera was developed to overcome the main limitation of traditional laparoscopic surgery, which is two-dimensional (2D) vision. The aim of our article is to present the largest casistic of 3D laparoscopic radical prostatectomy (LRP) available in literature and evaluate our results in terms of pentafecta and compare it with the literature. Methods We retrospectively evaluated consecutive patients who underwent LRP with 3D technology between March 2014 and December 2015. Total operative time (TOT), anasthomosis time (AT), blood loss and complications were registered. All patients presented at least 3 months of follow-up. Surgical…