Search results for "three-dimensional"

showing 10 items of 370 documents

A Lack of Sexual Dimorphism in Width-to-Height Ratio in White European Faces Using 2D Photographs, 3D Scans, and Anthropometry

2012

Facial width-to-height ratio has received a great deal of attention in recent research. Evidence from human skulls suggests\ud that males have a larger relative facial width than females, and that this sexual dimorphism is an honest signal of\ud masculinity, aggression, and related traits. However, evidence that this measure is sexually dimorphic in faces, rather than\ud skulls, is surprisingly weak. We therefore investigated facial width-to-height ratio in three White European samples using\ud three different methods of measurement: 2D photographs, 3D scans, and anthropometry. By measuring the same\ud individuals with multiple methods, we demonstrated high agreement across all measures. Ho…

MaleSexual SelectionAnatomy and PhysiologyVeterinary Anatomy and PhysiologySocial and Behavioral SciencesBody Mass IndexAnimal Musculoskeletal AnatomyPhotographyMusculoskeletal SystemMusculoskeletal Anatomymedia_commonEvolutionary TheorySex CharacteristicsMultidisciplinaryEcologyAnthropometryQRWhite (mutation)medicine.anatomical_structureMasculinityMedicineFemalemedicine.symptomResearch ArticleSex characteristicsAdultEvolutionary ProcessesAdolescentSciencemedia_common.quotation_subjectBFBiologyWhite PeopleYoung AdultImaging Three-DimensionalmedicineHumansBiologyEvolutionary BiologyAggressionC182 EvolutionC830 Experimental PsychologyAnthropometryC800 PsychologySexual dimorphismSkullEvolutionary EcologyAnthropologyFaceVeterinary ScienceBody mass indexDemographyPLoS ONE
researchProduct

Sensors / Cross-country skiing analysis and ski technique detection by high-precision kinematic global navigation satellite system

2019

Cross-country skiing (XCS) embraces a broad variety of techniques applied like a gear system according to external conditions, slope topography, and skier-related factors. The continuous detection of applied skiing techniques and cycle characteristics by application of unobtrusive sensor technology can provide useful information to enhance the quality of training and competition. (1) Background: We evaluated the possibility of using a high-precision kinematic global navigation satellite system (GNSS) to detect cross-country skiing classical style technique. (2) Methods: A world-class male XC skier was analyzed during a classical style 5.3-km time trial recorded with a high-precision kinemat…

MaleTime FactorsGPSVideo RecordingSTRIDEVideo cameraKinematics01 natural sciencesBiochemistryDisplacement (vector)ArticleAnalytical Chemistrylaw.invention03 medical and health sciences0302 clinical medicineTime trialImaging Three-DimensionallawSkiingHumansElectrical and Electronic Engineeringkinematic GNSSInstrumentationMathematicsbusiness.industryAltitude010401 analytical chemistry030229 sport sciencesGeodesySatellite CommunicationshiihtoAtomic and Molecular Physics and Optics0104 chemical sciencesBiomechanical PhenomenaGNSS applicationssatelliittipaikannusTrajectoryGlobal Positioning Systembusinessclassical techniquecross-country skiing
researchProduct

Quantitation of Microcomputed Tomography-Imaged Ocular Microvasculature

2010

To quantitatively assess microvascular dimensions in the eyes of neonatal wild-type and VEGF(120)-tg mice, using a novel combination of techniques which permit three-dimensional (3D) image reconstruction.A novel combination of techniques was developed for the accurate 3D imaging of the microvasculature and demonstrated on the hyaloid vasculature of the neonatal mouse eye. Vascular corrosion casting is used to create a stable replica of the vascular network and X-ray microcomputed tomography (muCT) to obtain the 3D images. In-house computer-aided image analysis techniques were then used to perform a quantitative morphological analysis of the images.With the use of these methods, differences …

MaleVascular Endothelial Growth Factor APathologymedicine.medical_specialtyX-ray microtomographyPhysiologyVEGF receptorsGene ExpressionMice TransgenicIterative reconstructionCorrosion CastingEyeMiceImaging Three-DimensionalPhysiology (medical)medicineAnimalsProtein IsoformsMolecular Biologybiologybusiness.industryMicrocirculationMicro computed tomographyX-Ray MicrotomographyMicrocomputed tomographyCapillariesMice Inbred C57BLPhenotypeAnimals NewbornMicroscopy Electron Scanningbiology.proteinFemaleCardiology and Cardiovascular MedicinebusinessBiomedical engineeringMicrocirculation
researchProduct

Echocardiographic reference ranges for normal left atrial function parameters results from the EACVI NORRE study

2018

International audience; Aims - To obtain the normal ranges for echocardiographic measurements of left atrial (LA) function from a large group of healthy volunteers accounting for age and gender. Methods and results - A total of 371 (median age 45 years) healthy subjects were enrolled at 22 collaborating institutions collaborating in the Normal Reference Ranges for Echocardiography (NORRE) study of the European Association of Cardiovascular Imaging (EACVI). Left atrial data sets were analysed with a vendor-independent software (VIS) package allowing homogeneous measurements irrespective of the echocardiographic equipment used to acquire data sets. The lowest expected values of LA function we…

Maledeformation imagingPump functionEchocardiography Three-DimensionalSex Factor030204 cardiovascular system & hematologyCohort Studies0302 clinical medicineLeft atrialReference ValuesHealthy volunteersImage Processing Computer-AssistedAge Factoradult echocardiography; deformation imaging; left atrial function; reference values030212 general & internal medicineMultivariate AnalysiObserver VariationHealthy subjectsAge FactorsGeneral MedicineMiddle AgedReference StandardsHealthy VolunteerHealthy VolunteersHomogeneousRadiology Nuclear Medicine and imagingEchocardiographyCardiologyLinear ModelAtrial Function LeftFemale[SDV.IB]Life Sciences [q-bio]/BioengineeringCardiology and Cardiovascular MedicineHumanAdultmedicine.medical_specialtyadult echocardiographyStatistics Nonparametric03 medical and health sciencesSex FactorsInternal medicinemedicineHumansRadiology Nuclear Medicine and imagingHeart AtriaLeft atrial functionbusiness.industryreference valueMED/11 - MALATTIE DELL'APPARATO CARDIOVASCOLAREReference valuesMultivariate AnalysisLinear ModelsReference StandardParameterCohort StudieLarge groupbusiness
researchProduct

Clinical application of back surface topography by means of structured light in the screening of idiopathic scoliosis

2016

We present the results of the clinical validity in the screening of idiopathic scoliosis with a nonharming method of back surface topography by means of structured light projection. A total of 155 patients were evaluated (mean age 13.3 years). They were divided into two groups: pathologic patients (scoliosis) and nonpathologic patients (control and asymmetries). An analytical case-control study was carried out. Our topographic method obtained 92% sensitivity and 74% specificity as a screening test in identifying patients with scoliosis (P=0.05). We could quantify the vertebral deformity of scoliosis in the three spatial planes by means of three topographic variables, Horizontal Plane Deform…

Malemedicine.medical_specialtyAdolescentLightIdiopathic scoliosisScoliosisSensitivity and SpecificityYoung Adult03 medical and health sciencesImaging Three-Dimensional0302 clinical medicineDeformitymedicineHumansScattering RadiationOrthopedics and Sports MedicineChildOrthodonticsBack030222 orthopedicsVERTEBRAL DEFORMITYbusiness.industryReproducibility of Resultsmedicine.diseaseTrunkSpineSurgeryROC CurveScoliosisCase-Control StudiesPediatrics Perinatology and Child HealthClinical validityFemalemedicine.symptombusinessAlgorithms030217 neurology & neurosurgerySymmetry indexStructured lightJournal of Pediatric Orthopaedics B
researchProduct

3D versus 2D contrast-enhanced sonography in the evaluation of therapeutic response of hepatocellular carcinoma after locoregional therapies: prelimi…

2014

Objective: To investigate diagnostic performance of 3D contrast-enhanced ultrasound (CEUS) compared with 2D CEUS in the assessment of therapeutic response of hepatocellular carcinoma (HCC) treated with locoregional therapies (LRT). Materials and methods: Twenty-three consecutive patients (13 men and 10 women; mean age 65.5 years) with 23 HCCs (size range 1.2–7.2 cm; mean size 2.9 ± 1.4 cm) treated by means of radiofrequency ablation (RFA n = 9), transarterial chemoembolization (TACE n = 8), combined RFA and TACE (n = 3), percutaneous alcoholization (n = 2), and wedge resection (n = 1) underwent 2D and 3D CEUS 1 month (30 ± 2 days) after treatment. Magnetic resonance (n = 17) and computed to…

Malemedicine.medical_specialtyCarcinoma HepatocellularHepatocellular carcinomaRadiofrequency ablationContrast-enhanced 3D ultrasoundSulfur HexafluorideContrast MediaIopamidollaw.inventionImaging Three-DimensionallawImage Interpretation Computer-AssistedCarcinomamedicineHumansRadiology Nuclear Medicine and imagingPhospholipidsUltrasonography InterventionalAgedNeuroradiologyAged 80 and overmedicine.diagnostic_testbusiness.industryMedicine (all)Liver NeoplasmsUltrasoundInterventional radiologyMagnetic resonance imagingGeneral MedicineMiddle Agedmedicine.diseaseMagnetic Resonance ImagingIopamidolPhospholipidContrast agentTreatment OutcomeLiverLiver NeoplasmHepatocellular carcinomaFemaleRadiologyTomography X-Ray ComputedbusinessHumanmedicine.drugLa radiologia medica
researchProduct

Hepatocellular cancer response to radiofrequency tumor ablation: contrast-enhanced ultrasound

2007

Radiofrequency ablation (RFA) is increasingly being used as percutaneous treatment of choice for patients with early stage hepatocellular carcinoma (HCC). An accurate assessment of the RFA therapeutic response is of crucial importance, considering that a complete tumor ablation significantly increases patient survival, whereas residual unablated tumor calls for additional treatment. Imaging modalities play a pivotal role in accomplishing this task, but ultrasound (US) is not considered a reliable modality for the evaluation of the real extent of necrosis, even when color/power Doppler techniques are used. Recently, newer microbubble-based US contrast agents used in combination with grey-sca…

Malemedicine.medical_specialtyCarcinoma HepatocellularPercutaneousRadiofrequency ablationUrologymedicine.medical_treatmentSulfur HexafluorideContrast MediaCatheter ablationSensitivity and Specificitylaw.inventionImaging Three-DimensionallawHumansMedicineRadiology Nuclear Medicine and imagingStage (cooking)PhospholipidsUltrasonography InterventionalAgedAged 80 and overRadiological and Ultrasound Technologybusiness.industryLiver NeoplasmsUltrasoundGastroenterologyGeneral MedicineRadiofrequency ablationcontrast-enhanced ultrasound hepatocellular carcinomamedicine.diseaseTreatment OutcomeHepatocellular carcinomaCatheter AblationDisease ProgressionMicrobubblesFemaleRadiologybusinessContrast-enhanced ultrasoundAbdominal Imaging
researchProduct

Evaluation of ultrasound transmission velocity and 3-dimensional radiology in different bone types for dental implantology: a comparative ex vivo stu…

2013

Objective To evaluate ultrasound transmission velocity (UTV) for assessment of mechanical bone quality, an ex vivo comparison of different bone types measured with UTV, 2-dimensional (2D) histomorphometry and with 3-dimensional (3D) radiology (cone-beam computerized tomography [CBCT], computerized microtomography [μCT]) was conducted. Study Design Clinical cortical, cancellous, and mixed bone (each n = 6) was measured via UTV (m/s), CBCT (white pixel/black pixel ratio [WP/BP]), μCT (bone volume/total volume [μBV/TV]), and histomorphometry (bone volume/total volume [hBV/TV]). UTV values were correlated with 2D-histomorphometry and 3D-radiologic results. Results For the cortical, cancellous, …

Malemedicine.medical_specialtyCone beam computed tomographyX-ray microtomographyBone densitySwineTransducersRibsBone and BonesPathology and Forensic MedicineIliumDental implantologyImaging Three-DimensionalBone DensitymedicineImage Processing Computer-AssistedAnimalsRadiology Nuclear Medicine and imagingDentistry (miscellaneous)UltrasonicsUltrasonographybusiness.industryUltrasoundDental Implantation EndosseousX-Ray MicrotomographyCone-Beam Computed TomographySurgeryRadiologyTomographyOral SurgerybusinessBone volumeEx vivoOral surgery, oral medicine, oral pathology and oral radiology
researchProduct

Comparison of Two- and Three-Dimensional Unenhanced and Contrast-Enhanced Echocardiographies Versus Cineventriculography Versus Cardiac Magnetic Reso…

2013

Contrast enhancement has been shown to improve detection of regional wall motion abnormalities (RWMA) in 2-dimensional (2D) echocardiography. This study determined the use of contrast enhancement in the setting of 3-dimensional (3D) echocardiography for definition of left ventricular RWMA compared with 2D echocardiography, cineventriculography, and cardiac magnetic resonance (CMR). In 63 patients, unenhanced and contrast-enhanced (SonoVue; Bracco Imaging S.p.A., Milan, Italy) 2D and 3D echocardiographies, CMR, and cineventriculography were performed. Hypokinesia in ≥1 segment defined the presence of RWMA. Interreader agreement (IRA) between 2 blinded off-site readers on presence of RWMA was…

Malemedicine.medical_specialtyContrast enhancementmedia_common.quotation_subjectEchocardiography Three-DimensionalContrast MediaMagnetic Resonance Imaging CineVentricular Function LeftVentricular Dysfunction Left2d echocardiographyInternal medicinemedicineHumansContrast (vision)Wall motionmedia_commonmedicine.diagnostic_testVentricular functionbusiness.industryCineradiographyReproducibility of ResultsMagnetic resonance imagingMiddle AgedContrast echocardiographyCardiologyFemaleCardiology and Cardiovascular MedicineCardiac magnetic resonancebusinessFollow-Up StudiesThe American Journal of Cardiology
researchProduct

Imaging processing for CT angiography of the cervicocranial arteries: evaluation of reformatting technique.

2007

Purpose. The aim of this study was to compare computed tomography angiography (CTA) sliding-thin-slab (STS) multiplanar reformatting (MPR), STS maximum intensity projection (MIP) and three-dimensional (3D) volume rendering (VR) reformatting techniques in the evaluation of cervicocranial arteries. Materials and methods. Twenty patients examined with multislice CT were included in this study. CTA images were reformatted as STS-MIP, STS-MPR and 3DVR in orthogonal planes and in the oblique-coronal plane. Images were evaluated in consensus by two radiologists, with a third radiologist to resolve discordances in grading image quality parameters. The Spearman correlation analysis was performed to …

Malemedicine.medical_specialtyImage qualityCT CT angiography Cervicocranial arterieImaging Three-DimensionalmedicineImage Processing Computer-AssistedHumansRadiology Nuclear Medicine and imagingVertebral ArteryComputed tomography angiographyNeuroradiologyAgedmedicine.diagnostic_testbusiness.industryUltrasoundAngiographyBrainVolume renderingGeneral MedicineCerebral ArteriesMiddle AgedCerebral AngiographyCerebrovascular DisordersCarotid ArteriesMaximum intensity projectionAngiographyCervical VertebraeFemaleRadiologyImaging processingNuclear medicinebusinessTomography X-Ray ComputedLa Radiologia medica
researchProduct