Search results for "three-dimensional"
showing 10 items of 370 documents
Assessing thoraco-pelvic covariation in Homo sapiens and Pan troglodytes: A 3D geometric morphometric approach
2019
[Objectives]: Understanding thoraco-pelvic integration in Homo sapiens and their closest living relatives (genus Pan) is of great importance within the context of human body shape evolution. However, studies assessing thoraco-pelvic covariation across Hominoidea species are scarce, although recent research would suggest shared covariation patterns in humans and chimpanzees but also species-specific features, with sexual dimorphism and allometry influencing thoraco-pelvic covariation in these taxa differently.
Emotional words induce enhanced brain activity in schizophrenic patients with auditory hallucinations.
2005
Neuroimaging studies of emotional response in schizophrenia have mainly used visual (faces) paradigms and shown globally reduced brain activity. None of these studies have used an auditory paradigm. Our principal aim is to evaluate the emotional response of patients with schizophrenia to neutral and emotional words. An auditory emotional paradigm based on the most frequent words heard by psychotic patients with auditory hallucinations was designed. This paradigm was applied to evaluate cerebral activation with functional magnetic resonance imaging (fMRI) in 11 patients with schizophrenia with persistent hallucinations and 10 healthy subjects. We found a clear enhanced activity of the fronta…
3D-printing-assisted fabrication of chitosan scaffolds from different sources and cross-linkers for dental tissue engineering
2021
The aim of the present study was to fabricate and characterise chitosan scaffolds from animal and fungal sources, with or without gelatine as a co-polymer, and cross-linked to 3-glycidyloxyproply trimethoxysilane (GPTMS) or genipin for application in dental root tissue engineering. Chitosan-based scaffolds were prepared by the emulsion freeze-drying technique. Scanning electron microscopy (SEM) and nano-focus computed tomography (nano-CT) were used to characterise scaffold microstructure. Chemical composition and cross-linking were evaluated by Fourier transform infrared-attenuated total reflectance spectroscopy. Compression tests were performed to evaluate scaffold mechanical properties. S…
Shape change in the atlas with congenital midline non-union of its posterior arch: a morphometric geometric study.
2017
Background Context The congenital midline non-union of the posterior arch of the atlas is a developmental variant present at a frequency ranging from 0.7% to 3.9%. Most of the reported cases correspond to incidental findings during routine medical examination. In cases of posterior non-union, hypertrophy of the anterior arch and cortical bone thickening of the posterior arches have been observed and interpreted as adaptive responses of the atlas to increased mechanical stress. Purpose We sought to determine if the congenital non-union of the posterior arch results in a change in the shape of the atlas. Study Design/Setting This study is an analysis of the first cervical vertebrae from osteo…
Long-term bony integration and resorption kinetics of a xenogeneic bone substitute after sinus floor augmentation: histomorphometric analyses of huma…
2013
In this case series, a systematic histomorphometric analysis of two human bone biopsy specimens was conducted 1 and 5 years after grafting with a xenogeneic bovine bone substitute material (BSM). While the 1-year specimen still showed extensive signs of an active desmal ossification, the specimen after 5 years mainly showed mature lamellar bone without bone turnover or remodeling. A completed bony integration without extensive resorption of the BSM particles could be detected. Altogether, a good integration in the bone with osteoconduction and a high biocompatibility was seen.
Quantitative analysis of emphysema in 3D using MDCT: Influence of different reconstruction algorithms
2008
Abstract Purpose The aim of the study was to compare the influence of different reconstruction algorithms on quantitative emphysema analysis in patients with severe emphysema. Material and methods Twenty-five patients suffering from severe emphysema were included in the study. All patients underwent inspiratory MDCT (Aquilion-16, slice thickness 1/0.8 mm). The raw data were reconstructed using six different algorithms: bone kernel with beam hardening correction (BHC), soft tissue kernel with BHC; standard soft tissue kernel, smooth soft tissue kernel (internal reference standard), standard lung kernel, and high-convolution kernel. The only difference between image data sets was the algorith…
Intraoperative C-arm CT imaging in angular stable plate osteosynthesis of distal radius fractures
2013
The purpose of this study was to analyze the practicability and benefit of intraoperative C-arm computed tomography (CT) imaging in volar plate osteosynthesis of unstable distal radius fractures. During a 1 year period, intraoperative three dimensional (3D) imaging with the ARCADIS Orbic 3D was performed in addition to standard fluoroscopy in 51 cases. The volar angular stable plate oesteosyntheses were analyzed intraoperatively and, if necessary, improved immediately. The duration of the scan and radiation exposure dose were measured. On average, performance of the scan and analysis of the CT dataset took 6.7 minutes. In 31.3% of the surgeries a misplacement of screws was detected and cor…
Quantitative Assessment of Right Ventricular Volumes in Severe Chronic Thromboembolic Pulmonary Hypertension using Transthoracic Three-dimensional Ec…
2002
Evaluation of a three-dimensional reconstruction method to show the changes of right ventricular volume and systolic function when patients undergo pulmonary thromboendarterectomy for chronic thromboembolic pulmonary hypertension.In the examination of 11 patients (four female, seven male; age 56+/-10 years) before and after pulmonary thromboendarterectomy, end-diastolic and end-systolic right ventricular volumes were determined as a sum total of the calculated volumes of derived parallel slices of the right ventricle. Using a Tomtec workstation and a Vingmed CFM 800 echocardiography device, the acquired data were ECG-and respiration-triggered in the course of transthoracic examination, usin…
Colorectal Polyps: Detection with Dark-Lumen MR Colonography versus Conventional Colonoscopy
2005
To prospectively compare dark-lumen magnetic resonance (MR) colonography with conventional colonoscopy in the detection of colorectal polyps.Local ethical committee approval and informed consent were obtained. One hundred consecutive patients (56 men, 44 women; mean age +/- standard deviation, 67.7 years +/- 14.7; range, 25-82 years) who were referred for conventional colonoscopy from January 2003 to January 2004 underwent MR colonography and conventional colonoscopy after standard precolonoscopic bowel cleansing. Colonoscopy was performed immediately after MR colonography. For MR colonography, the colon was filled with approximately 2000 mL of tap water. Imaging was performed with a 1.5-T …
Three-dimensional images contribute to the diagnosis of mucous retention cyst in maxillary sinus
2011
Objective: To evaluate the detection of mucous retention cyst of maxillary sinus (MRCMS) using panoramic radiography and cone beam computed tomography (CBCT). Study Design: A digital database with 6,000 panoramic radiographs was reviewed for MRCMS. Suggestive images of MRCMS were detected on 185 radiographs, and patients were located and invited to return for follow-up. Thirty patients returned, and control panoramic radiographs were obtained 6 to 46 months after the initial radiograph. When MRCMS was found on control radiographs, CBCT scans were obtained. Cysts were measured and compared on radiographs and scans. The Wilcoxon, Spearman and Kolmorogov-Smirnov tests were used for statistical…