Search results for "time"
showing 10 items of 12336 documents
Enhanced loss model algorithm for interior permanent magnet synchronous machines
2017
This paper presents an experimental study on the impact of the parameter variations over the performances of a LMA (Loss Model Algorithm) designed for an IPMSM (Interior Permanent Magnet Synchronous Machine). In a previous work, the characterization was carried out by assessing, for several working conditions, the motor parameters that influence the motor efficiency. The proposed enhanced loss model algorithm is implemented in a rapid prototyping system and its performances, in term of efficiency, are compared with other control systems, obtaining promising results.
Real-time signal processing in embedded systems
2016
International audience
The role of radio frequency scattering in high-energy electron losses from minimum-B ECR ion source
2021
Abstract The measurement of the axially lost electron energy distribution escaping from a minimum-B electron cyclotron resonance ion source in the range of 4–800 keV is reported. The experiments have revealed the existence of a hump at 150–300 keV energy, containing up to 15% of the lost electrons and carrying up to 30% of the measured energy losses. The mean energy of the hump is independent of the microwave power, frequency and neutral gas pressure but increases with the magnetic field strength, most importantly with the value of the minimum-B field. Experiments in pulsed operation mode have indicated the presence of the hump only when microwave power is applied, confirming that the origi…
Very Long Term Stabilization of a 2D Magnet down to the Monolayer for Device Integration
2020
2D materials have recently demonstrated a strong potential for spintronic applications. This has been further reinforced by the discovery of ferromagnetic 2D layers. Nevertheless, the fragility of ...
The biased disc of an electron cyclotron resonance ion source as a probe of instability-induced electron and ion losses
2019
International audience; Electron Cyclotron Resonance Ion Source (ECRIS) plasmas are prone to kinetic instabilities resulting in loss of electron and ion confinement. It is demonstrated that the biased disk of an ECRIS can be used as a probe to quantify such instability-induced electron and ion losses occurring in less than 10 µs. The qualitative interpretation of the data is supported by the measurement of the energy spread of the extracted ion beams implying a transient plasma potential >1.5 kV during the instability. A parametric study of the electron losses combined with electron tracking simulations allows for estimating the fraction of electrons expelled in each instability event to be…
Carbonyl-functionalized quaterthiophenes: a study of the vibrational Raman and electronic absorption/emission properties guided by theoretical calcul…
2011
This work investigates the evolution of the molecular, vibrational, and optical properties within a family of carbonyl-functionalized quaterthiophenes: 5,5'''-diheptanoyl-2,2':5',2'':5'',2'''-quaterthiophene (1), 5,5'''-diperfluorohexylcarbonyl-2,2':5',2'':5'',2'''-quaterthiophene (2), and 2,7-[bis(5-perfluorohexylcarbonylthien-2-yl)]-4H-cyclopenta[2,1-b:3,4-b']-dithiophene-4-one (3). The analysis is performed by Raman and UV/Vis absorption/excitation/fluorescence spectroscopy in combination with density functional calculations. Theoretical calculations show that substitution with carbonyl groups and perfluorohexyl chains induces progressive quinoidization of the π-conjugated backbone in co…
Laser-induced enhancement of tunneling in NHD2
2012
We apply and explore techniques aiming at enhancing the tunneling by laser fields, originally developed for a one-dimensional model, to a complete six-dimensional vibrational model of the inversion motion in NHD(2). The computational study is performed with the multi-configuration time-dependent Hartree method. Assuming an ideal three-dimensional alignment we obtain a driven tunneling time twenty times smaller than the natural one, in rather good agreement with an oversimplified three-state model. In the case of one-dimensional alignment, a linearly polarized field leads to a poor enhancement of the tunneling probability, after averaging over the rotation about the alignment axis, whereas a…
The first example of cofacial bis(dipyrrins)
2016
International audience; Two series of cofacial bis(dipyrrins) were prepared and their photophysical properties as well as their bimolecular fluorescence quenching with C-60 were investigated. DFT and TDDFT computations were also performed as a modeling tool to address the nature of the fluorescence state and the possible inter-chromophore interactions. Clearly, there is no evidence for such interactions and the bimolecular quenching of fluorescence, in comparison with mono-dipyrrins, indicates that C-60-bis(dipyrrin) contacts occur from the outside of the "mouth" of the cofacial structure.
NMR T1-Relaxation Measurements on Paramagnetic Organolanthanides: An Alternative Tool for Structure Determination in Solution
2005
1H NMR investigations were conducted on four paramagnetic organolanthanides, all bearing the tetraisopropylcyclopentadienyl ligand Cp4i (HC5iPr4) in order to verify whether or not interactions observed in the solid state are maintained in solution. In some cases variable-temperature experiments were necessary to enhance the resolution and determine the best conditions for the study. The 1D NMR spectrum could be interpreted in every case. Complementary 2D COSY experiments allowed the full attribution of the signals. T1 (1H) relaxation values were determined for all the paramagnetic complexes at the most suitable temperature, and compared with those of the diamagnetic KCp4i. The same tendency…
Analysis of psychoactive substances in water by information dependent acquisition on a hybrid quadrupole time-of-flight mass spectrometer.
2016
Emerging drugs of abuse, belonging to many different chemical classes, are attracting users with promises of “legal” highs and easy access via internet. Prevalence of their consumption and abuse through wastewater-based epidemiology can only be realized if a suitable analytical screening procedure exists to detect and quantify them in water. Solid-phase extraction and ultra-high performance liquid chromatography quadrupole time-of-flight-mass spectrometry (UHPLC–QqTOF–MS/MS) was applied for rapid suspect screening as well as for the quantitative determination of 42 illicit drugs and metabolites in water. Using this platform, we were able to identify amphetamines, tryptamines, piperazines, p…