Search results for "tomography"
showing 10 items of 2332 documents
Giant peripheral osteoma of the mandible simulating a parotid gland tumor
2019
Sin financiación 1.405 JCR (2019) Q3, 28/42 Otorhinolaringology 0.528 SJR (2019) Q2, 54/111 Otorhinolaryngology No data IDR 2019 UEV
A new method for radiochemical separation of arsenic from irradiated germanium oxide.
2005
Abstract Radioarsenic labelled radiopharmaceuticals could be a valuable asset to Positron Emission Tomography (PET). In particular, the long half-lives of 72 As ( T 1/2 =26 h) and 74 As ( T 1/2 =17.8 d) allow to investigate slow physiological or metabolical processes, like the enrichment and distribution of antibodies in tumor tissue. This work describes the direct production of no-carrier-added (nca) arsenic isotopes *As, with *=71, 72, 73, 74 or 77, the reaction to [*As]AsI 3 and its radiochemical separation from the irradiated solid germanium oxide via polystyrene-based solid-phase extraction. The germanium oxide target, irradiated at a cyclotron or a nuclear reactor, is dissolved in con…
Post-elution processing of 44Ti/44Sc generator-derived 44Sc for clinical application
2009
The (44)Ti/(44)Sc (T(1/2)(44)Ti=60a) generator provides cyclotron-independent access to positron-emitting (44)Sc (T(1/2)=3.97d) for PET imaging. This work aims to post-elution processing of initial (44)Sc generator eluates in order to reduce its volume, HCl concentration and remove the oxalate anions. The on-line adsorption of (44)Sc on cationic resin AG 50W-X8 (200-400 mesh, H(+)-form) is achieved with >98% efficacy. Subsequently, the purified (44)Sc is desorbed by using 3ml of 0.25M ammonium acetate (pH=4.0). The post-processing takes 10min. The overall yield of the post-processing reached 90%, which is referred to the (44)Sc obtained from the (44)Ti/(44)Sc generator. In addition to the c…
Joint image and motion reconstruction for PET using a B-spline motion model.
2012
We present a novel joint image and motion reconstruction method for PET. The method is based on gated data and reconstructs an image together with a motion function. The motion function can be used to transform the reconstructed image to any of the input gates. All available events (from all gates) are used in the reconstruction. The presented method uses a B-spline motion model, together with a novel motion regularization procedure that does not need a regularization parameter (which is usually extremely difficult to adjust). Several image and motion grid levels are used in order to reduce the reconstruction time. In a simulation study, the presented method is compared to a recently propos…
Small Bowel Perforations: What the Radiologist Needs to Know
2016
The incidence of small bowel perforation is low but can develop from a variety of causes including Crohn disease, ischemic or bacterial enteritis, diverticulitis, bowel obstruction, volvulus, intussusception, trauma, and ingested foreign bodies. In contrast to gastroduodenal perforation, the amount of extraluminal air in small bowel perforation is small or absent in most cases. This article will illustrate the main aspects of small bowel perforation, focusing on anatomical reasons of radiological findings and in the evaluation of the site of perforation using plain film, ultrasound, and multidetector computed tomography equipments. In particular, the authors highlight the anatomic key notes…
2017
In the context of radiopharmacy and molecular imaging, the concept of theranostics entails a therapy-accompanying diagnosis with the aim of a patient-specific treatment. Using the adequate diagnostic radiopharmaceutical, the disease and the state of the disease are verified for an individual patient. The other way around, it verifies that the radiopharmaceutical in hand represents a target-specific and selective molecule: the “best one” for that individual patient. Transforming diagnostic imaging into quantitative dosimetric information, the optimum radioactivity (expressed in maximum radiation dose to the target tissue and tolerable dose to healthy organs) of the adequate radiotherapeutica…
A fully automatic approach for multimodal PET and MR image segmentation in gamma knife treatment planning
2017
The aim of this study is to combine Biological Target Volume (BTV) segmentation and Gross Target Volume (GTV) segmentation in stereotactic neurosurgery.Our goal is to enhance Clinical Target Volume (CTV) definition, including metabolic and morphologic information, for treatment planning and patient follow-up.We propose a fully automatic approach for multimodal PET and MR image segmentation. This method is based on the Random Walker (RW) and Fuzzy C-Means clustering (FCM) algorithms. A total of 19 brain metastatic tumors, undergone stereotactic neuro-radiosurgery, were retrospectively analyzed. A framework for the evaluation of multimodal PET/MRI segmentation is presented, considering volume…
A new method to evaluate the influence of the glenosphere positioning on stability and range of motion of a reverse shoulder prosthesis
2019
Abstract Purpose Shoulder instability and reduced range of motion are two common complications of a total reverse shoulder arthroplasty. In this work, a new approach is proposed to estimate how the glenoid component positioning can influence the stability and the range of motion of a reverse shoulder prosthesis. Materials and methods A standard reverse shoulder prosthesis has been analysed. To perform virtual simulation of the shoulder-prosthesis assembly, all the components of the prosthesis have been acquired via a 3D laser scanner and the solid models of the shoulder bones have been reconstructed through CT images. Loads on the shoulder joint have been estimated using anatomical models d…
68 Ga‐Labelled Tropane Analogues for the Visualization of the Dopaminergic System
2020
Abstract The development of radiometal‐labelled pharmaceuticals for neuroimaging could offer great potential due to easier handling during labelling and availability through radionuclide generator systems. Nonetheless, to date, no such tracers are available for positron emission tomography, primarily owing to the challenge of crossing the blood–brain barrier (BBB) and loss of affinity through chelator attachment. We have prepared a variety of 68Ga‐labelled phenyltropanes showing that, through a simple hydrocarbon‐linker, it is possible to introduce a chelator onto the lead structure while maintaining its high affinity for hDAT (human dopamine transporter) and simultaneously achieving adequa…
Re-irradiation With Carbon Ion Radiotherapy for Pelvic Rectal Cancer Recurrences in Patients Previously Irradiated to the Pelvis
2020
Background/Aim: Re-irradiation of locally recurrent rectal cancer poses challenges due to the proximity of critical organs, such as the bowel. This study aimed at evaluating the safety and efficacy of re-irradiation with Carbon Ion Radiotherapy (CIRT) in rectal cancer patients with local recurrence. Patients and Methods: Between 2014 and 2018, 14 patients were treated at the National Center of Oncological Hadrontherapy (CNAO Foundation) with CIRT for locally recurrent rectal cancer. Results: All patients concluded the treatment. No G≥3 acute/late reaction nor pelvic infections were observed. The 1-year and 2-year local control rates were, 78% and 52%, respectively, and relapse occurred clos…