Search results for "tomography"

showing 10 items of 2332 documents

Autoimmune pancreatitis: A challenging diagnostic puzzle for clinicians

2010

Autoimmune pancreatitis is a form of pancreatitis with autoimmune stigmata that may present as either focal or diffuse gland involvement. In focal forms, autoimmune pancreatitis shares demographic, clinical, biochemical and imaging features with pancreatic cancer. Since autoimmune pancreatitis is a benign disease and steroid therapy can rapidly resolve symptoms, improve radiological findings and avoid unnecessary surgery, the current clinical challenge is how to differentiate autoimmune pancreatitis from pancreatic neoplasia. Even though definitive diagnosis of the disease is difficult, several diagnostic criteria have been proposed and progress has been made in imaging studies. The managem…

medicine.medical_specialtyBiopsyAutoimmune Diseases; Biopsy; Cholangiopancreatography; Endoscopic Retrograde; Contrast Media; Fluorodeoxyglucose F18; Humans; Magnetic Resonance Imaging; Pancreatitis; Positron-Emission Tomography; Tomography; X-Ray ComputedUnnecessary SurgeryContrast MediaDiseaseGastroenterologyAutoimmune DiseasesEndoscopic RetrogradeFluorodeoxyglucose F18Internal medicinePancreatic cancerBiopsymedicineHumansIntensive care medicineTomographyAutoimmune pancreatitisCholangiopancreatography Endoscopic RetrogradeHepatologymedicine.diagnostic_testBenign diseasebusiness.industryGastroenterologymedicine.diseaseMagnetic Resonance ImagingCholangiopancreatographyX-Ray ComputedSteroid therapyPancreatitisPositron-Emission TomographyPancreatitisTomography X-Ray ComputedbusinessDigestive and Liver Disease
researchProduct

Relationship of sex hormones to bone geometric properties and mineral density in early pubertal girls.

2004

This study aimed to evaluate the associations among serum 17beta-estradiol (E2), testosterone (T), sex hormone-binding globulin (SHBG), bone geometric properties, and mineral density in 248 healthy girls between the ages of 10 and 13 yr old. The left tibial shaft was measured by peripheral quantitative computed tomography (Stratec XCT-2000; Stratec Medizintechnik, GmbH, Pforzheim, Germany). The cortical bone and marrow cavity areas were expressed as proportions of the total tibial cross-sectional area (CSA). Cortical thickness and total volumetric bone mineral density (vBMD) were also determined. These tibial geometric and densitometric measures were correlated against the serum sex hormone…

medicine.medical_specialtyBone densityMedullary cavityEndocrinology Diabetes and MetabolismClinical BiochemistryPuberty PrecociousBiochemistryBone remodelingEndocrinologySex hormone-binding globulinAbsorptiometry PhotonBone DensityInternal medicineSex Hormone-Binding GlobulinmedicineHumansTestosteroneTibiaQuantitative computed tomographyChildGonadal Steroid HormonesBone mineralbiologymedicine.diagnostic_testEstradiolTibiabusiness.industryBiochemistry (medical)Endocrinologymedicine.anatomical_structurebiology.proteinCortical boneFemalebusinessTomography X-Ray ComputedThe Journal of clinical endocrinology and metabolism
researchProduct

Relation of PvuII site polymorphism in the COL1A2 gene to the risk of fractures in prepubertal Finnish girls.

2003

Genetic susceptibility to fractures may be detectable in early childhood. We evaluated the associations between the polymorphic PvuII site of the COL1A2 gene and bone properties assessed by different modalities (dual-energy X-ray absorptiometry; peripheral quantitative computed tomography; gel coupling scanning quantitative ultrasonometry; ultrasound bone sonometry), bone turnover markers, and the occurrence of fractures in 244 prepubertal Finnish girls. Tanner stage and physical characteristics did not differ significantly among girls with different COL1A2 genotypes. The polymorphism was not significantly associated with different bone properties or any of the bone turnover markers when gi…

medicine.medical_specialtyBone densityPhysiologyOsteoporosisBiologyPolymorphism Single NucleotideCollagen Type IBone remodelingFractures BoneBone DensityRisk FactorsInternal medicineGenotypeGeneticsmedicineHumansGenetic Predisposition to DiseaseTibiaQuantitative computed tomographyChildDeoxyribonucleases Type II Site-SpecificFinlandRetrospective StudiesBone mineralBinding SitesPolymorphism Geneticmedicine.diagnostic_testPubertyAnthropometrymedicine.diseaseEndocrinologyFemaleBone RemodelingCollagenPhysiological genomics
researchProduct

The actual state of computerized tomography (CT)-computer assisted tomography (CAT).

1977

medicine.medical_specialtyBrain Diseasesbusiness.industryBrain NeoplasmsComputer assisted tomographyBrainDiagnosis DifferentialCerebrovascular DisordersNeurologySpinal CordBrain InjuriesmedicineHumansMedical physicsSpinal DiseasesNeurology (clinical)RadiologyTomographyState (computer science)businessPneumoencephalographyTomography X-Ray ComputedNeuroradiologyDemyelinating DiseasesHydrocephalusJournal of neurology
researchProduct

Impact of the Tiloop Bra mesh in CT images and dose delivery in breast radiotherapy

2012

A new titanized breast mesh, TiLOOP Bra, is currently available for implantation in patients who require radiotherapy. The purpose of this work is to study the dosimetric effect of the presence of a TiLOOP Bra mesh on breast radiation treatment and radiographic imaging. The dosimetric effects have been measured for three X‐ray energies: 1.25 MeV, 6 MV and 18 MV, using radiochromic films placed at three different depths. These depths are representative of mesh location in breast during the radiotherapy treatment and hence, are of interest in this study. In order to assess the disturbance in a radiographic image, different computed tomographic (CT) studies of the mesh have been performed. The…

medicine.medical_specialtyBreast Implantsmedicine.medical_treatmentRadiographyBreast Neoplasmsmetallic artifactprothesesHounsfield scalemedicineRadiation Oncology PhysicsHumansDosimetryRadiology Nuclear Medicine and imagingInstrumentationtitanizationDose deliveryRadiationPhantoms Imagingbusiness.industryRadiotherapy Planning Computer-AssistedRadiotherapy DosageSurgical MeshRadiation therapySurgical meshmeshAbsorbed doseRadiographic Image Interpretation Computer-AssistedFemaleRadiologyTomographyTomography X-Ray ComputedbusinessNuclear medicine
researchProduct

Noninvasive diagnostic techniques of port wine stain.

2021

Port-wine stain (PWS) is a benign capillary malformation that most commonly occurs in the head and neck. It is present at birth and progresses over time. It is formed by progressive dilatation of post-capillary venules and is associated with hypertrophy and nodularity with increasing age, leading to cosmetic disfigurement and psychological aggravation. It is caused by genetic mosaicism in GNAQ and GNA11 genes. Histopathology is the gold standard for assessment of PWS but it is invasive and may cause scarring. Inadequate characterization of the lesions may predispose to inadequate treatment protocols as well as higher treatment dosages. Clinical evaluation of treatment efficacy is subjective…

medicine.medical_specialtyCapillary malformationVascular MalformationsPort-Wine StainDermatologyStain030207 dermatology & venereal diseases03 medical and health sciences0302 clinical medicineOptical coherence tomographyMedicineHumansHemangioma CapillaryMicroscopy Confocalmedicine.diagnostic_testbusiness.industryUltrasoundInfant NewbornPort-wine stainGold standard (test)Laser Doppler velocimetrymedicine.diseaseTristimulus colorimeterTreatment Outcome030220 oncology & carcinogenesisRadiologybusinessJournal of cosmetic dermatologyREFERENCES
researchProduct

Interreader Reliability of LI-RADS Version 2014 Algorithm and Imaging Features for Diagnosis of Hepatocellular Carcinoma: A Large International Multi…

2017

Purpose To determine in a large multicenter multireader setting the interreader reliability of Liver Imaging Reporting and Data System (LI-RADS) version 2014 categories, the major imaging features seen with computed tomography (CT) and magnetic resonance (MR) imaging, and the potential effect of reader demographics on agreement with a preselected nonconsecutive image set. Materials and Methods Institutional review board approval was obtained, and patient consent was waived for this retrospective study. Ten image sets, comprising 38-40 unique studies (equal number of CT and MR imaging studies, uniformly distributed LI-RADS categories), were randomly allocated to readers. Images were acquired…

medicine.medical_specialtyCarcinoma HepatocellularDatabases FactualIntraclass correlationMedical and Health Sciences030218 nuclear medicine & medical imaging03 medical and health sciencesDatabases0302 clinical medicineClinical ResearchRadiologistsmedicineHumansRadiology Nuclear Medicine and imagingTomographyReliability (statistics)FactualRetrospective StudiesCancerObserver Variationmedicine.diagnostic_testbusiness.industryCarcinomaLiver NeoplasmsReproducibility of ResultsMagnetic resonance imagingRetrospective cohort studyHepatocellularInstitutional review boardMagnetic Resonance ImagingConfidence intervalX-Ray ComputedNuclear Medicine & Medical ImagingPrivate practiceFeature (computer vision)030220 oncology & carcinogenesisBiomedical ImagingCarcinoma Hepatocellular Databases Factual Humans Liver Neoplasms Magnetic Resonance Imaging Observer Variation Radiologists Reproducibility of Results Retrospective Studies Tomography X-Ray Computed AlgorithmsRadiologyTomography X-Ray ComputedbusinessDigestive DiseasesAlgorithms
researchProduct

Targetoid appearance on T2-weighted imaging and signs of tumor vascular involvement: diagnostic value for differentiating HCC from other primary live…

2021

To evaluate targetoid appearance on T2-weighted imaging and signs of tumor vascular involvement as potential new LI-RADS features for differentiating hepatocellular carcinoma (HCC) from other non-HCC primary liver carcinomas (PLCs). This IRB-approved, retrospective study was performed at two liver transplant centers. The final population included 375 patients with pathologically proven lesions imaged between 2007 and 2017 with contrast-enhanced CT or MRI. The cohort consisted of 165 intrahepatic cholangiocarcinomas and 74 combined hepatocellular-cholangiocarcinomas, with the addition of 136 HCCs for control. Two abdominal radiologists (R1; R2) independently reviewed the imaging studies (112…

medicine.medical_specialtyCarcinoma HepatocellularHepatocellular carcinomaPopulationContrast MediaX-ray computedMalignancySensitivity and SpecificityLiver neoplasm030218 nuclear medicine & medical imaging03 medical and health sciencesMagnetic resonance imaging0302 clinical medicineOcclusionmedicineHumansRadiology Nuclear Medicine and imagingeducationTomographyIntrahepatic CholangiocarcinomaRetrospective StudiesIntrahepatic cholangiocarcinomaNeuroradiologyeducation.field_of_studymedicine.diagnostic_testbusiness.industryLiver NeoplasmsMagnetic resonance imagingInterventional radiologyGeneral Medicinemedicine.diseasedigestive system diseasesBile Ducts IntrahepaticBile Duct Neoplasms030220 oncology & carcinogenesisHepatocellular carcinomaRadiologybusinessEuropean Radiology
researchProduct

Myocardial blood flow quantification for evaluation of coronary artery disease by computed tomography

2017

During the last decade coronary computed tomography angiography (CTA) has become the preeminent non-invasive imaging modality to detect coronary artery disease (CAD) with high accuracy. However, CTA has a limited value in assessing the hemodynamic significance of a given stenosis due to a modest specificity and positive predictive value. In recent years, different CT techniques for detecting myocardial ischemia have emerged, such as CT-derived fractional flow reserve (FFR-CT), transluminal attenuation gradient (TAG), and myocardial CT perfusion (CTP) imaging. Myocardial CTP imaging can be performed with a single static scan during first pass of the contrast agent, with monoenergetic or dual…

medicine.medical_specialtyCardiac computed tomographyMyocardial blood flow quantificationPerfusion scanningFractional flow reserveReview Article030204 cardiovascular system & hematology030218 nuclear medicine & medical imagingCoronary artery disease03 medical and health sciencesMyocardial perfusion imaging0302 clinical medicineStress imagingInternal medicinemedicinemedicine.diagnostic_testbusiness.industryMyocardial perfusion imagingmedicine.diseaseRegadenosonDipyridamoleCoronary artery disease (CAD)StenosisCardiologyRadiologyCoronary vasodilatorbusinessCardiology and Cardiovascular MedicineSettore MED/36 - Diagnostica Per Immagini E Radioterapiamedicine.drug
researchProduct

Technical development in cardiac CT: current standards and future improvements—a narrative review

2020

Non-invasive depiction of coronary arteries has been a great challenge for imaging specialists since the introduction of computed tomography (CT). Technological development together with improvements in spatial, temporal, and contrast resolution, progressively allowed implementation of the current clinical role of the CT assessment of coronary arteries. Several technological evolutions including hardware and software solutions of CT scanners have been developed to improve spatial and temporal resolution. The main challenges of cardiac computed tomography (CCT) are currently plaque characterization, functional assessment of stenosis and radiation dose reduction. In this review, we will discu…

medicine.medical_specialtyCardiac computed tomographyPrognosiComputed tomography030204 cardiovascular system & hematology030218 nuclear medicine & medical imaging03 medical and health sciences0302 clinical medicinemedicineMedical physicsmedicine.diagnostic_testbusiness.industryContrast resolutionRadiation doseCoronary artery disease (CAD)Coronary arteriesmedicine.anatomical_structureAtherosclerosiCt scannersNarrative reviewTherapyReview Article on Impact of Cardiac CT in Clinical PracticeCardiology and Cardiovascular MedicinebusinessCardiac computed tomography (CCT)DiagnosiCardiovascular Diagnosis and Therapy
researchProduct