Search results for "transducer"

showing 10 items of 173 documents

A Phase-Locked Loop for the Synchronization of Power Quality Instruments in the Presence of Stationary and Transient Disturbances

2007

Power quality instrumentation requires accurate fundamental frequency estimation and signal synchronization, even in the presence of both stationary and transient disturbances. In this paper, the authors present a synchronization technique for power quality instruments based on a single-phase software phase-locked loop (PLL), which is able to perform the synchronization, even in the presence of such disturbances. Moreover, PLL is able to detect the occurrence of a transient disturbance. To evaluate if and how the synchronization technique is adversely affected by the application of stationary and transient disturbing influences, appropriate testing conditions have been developed, taking int…

Engineeringbusiness.industryFundamental frequencySignalSynchronizationPhase-locked loopTransducerInstrument synchronization phase-locked loop (PLL) control power quality transient disturbancesControl theoryElectronic engineeringInstrumentation (computer programming)Transient (oscillation)Electrical and Electronic EngineeringbusinessSettore ING-INF/07 - Misure Elettriche E ElettronicheInstrumentationVoltageIEEE Transactions on Instrumentation and Measurement
researchProduct

Automated single ring infiltrometer with a low-cost microcontroller circuit

2015

Automation of a new single ring infiltrometer.Data acquisition system based on the open source microcontroller platform Arduino.New method to minimize the disturbance of the soil surface.New approach to process transducer output. A method to automate data collection with a compact infiltrometer under constant head conditions was developed. The infiltrometer consists of a containment ring with a small quasi-constant head of water (i.e., 2-3mm) that is controlled by a Mariotte reservoir and a data acquisition system based on the open source microcontroller platform Arduino and a differential pressure transducer. The presented design can be easily reproduced and operated.The infiltrometer was …

Engineeringbusiness.industryGroup method of data handlingForestryHorticulturePressure sensorComputer Science ApplicationsMicrocontrollerHydraulic propertiesTransducerData acquisitionArduinoAutomated single-ring infiltrometerArduinoBEST (Beerkan Estimation of Soil Transfer parameters)Settore AGR/08 - Idraulica Agraria E Sistemazioni Idraulico-ForestaliInfiltrometerElectronic databusinessAgronomy and Crop ScienceSimulationComputers and Electronics in Agriculture
researchProduct

High-velocity Impact Location on Aircraft panels Using Macro-fiber Composite piezoelectric Rosettes

2010

In this article, an approach based on an array of macro-fiber composite (MFC) transducers arranged as rosettes is proposed for high-velocity impact location on isotropic and composite aircraft panels. Each rosette, using the directivity behavior of three MFC sensors, provides the direction of an incoming wave generated by the impact source as a principal strain angle. A minimum of two rosettes is sufficient to determine the impact location by intersecting the wave directions. The piezoelectric rosette approach is easier to implement than the well-known time-of-flight-based triangulation of acoustic emissions because it does not require knowledge of the wave speed in the material. Hence, th…

Engineeringbusiness.industryMechanical EngineeringAcousticsIsotropyTriangulation (social science)impact location structural health monitoring macro-fiber composite transducers acoustic emissions.DirectivityPiezoelectricitylaw.inventionOpticsAcoustic emissionlawNondestructive testingLight-gas gunGeneral Materials ScienceStructural health monitoringbusinessAstrophysics::Galaxy Astrophysics
researchProduct

Taking Advantage of Selective Change Driven Processing for 3D Scanning

2013

This article deals with the application of the principles of SCD (Selective Change Driven) vision to 3D laser scanning. Two experimental sets have been implemented: one with a classical CMOS (Complementary Metal-Oxide Semiconductor) sensor, and the other one with a recently developed CMOS SCD sensor for comparative purposes, both using the technique known as Active Triangulation. An SCD sensor only delivers the pixels that have changed most, ordered by the magnitude of their change since their last readout. The 3D scanning method is based on the systematic search through the entire image to detect pixels that exceed a certain threshold, showing the SCD approach to be ideal for this applicat…

Event-based visionLaser scanningComputer scienceTransducers3d scanninglcsh:Chemical technologySensitivity and SpecificityBiochemistryArticleAnalytical Chemistrylaw.inventionPhotometryPhotometry (optics)Imaging Three-DimensionallawInformàticaNyquist–Shannon sampling theoremComputer visionlcsh:TP1-11853D scanningElectrical and Electronic Engineeringhigh-speed visual acquisitionInstrumentationPixelbusiness.industryLasers3D reconstructionReproducibility of ResultsSignal Processing Computer-AssistedEquipment DesignImage EnhancementLaserAtomic and Molecular Physics and OpticsEquipment Failure AnalysisTransducerSemiconductorsCMOSArtificial intelligencebusinessHigh-speed visual acquisitionevent-based visionSensors
researchProduct

Modeling the electromechanical impedance technique for the assessment of dental implant stability

2015

We simulated the electromechanical impedance (EMI) technique to assess the stability of dental implants. The technique consists of bonding a piezoelectric transducer to the element to be monitored. When subjected to an electric field, the transducer induces structural excitations which, in turn, affect the transducer's electrical admittance. As the structural vibrations depend on the mechanical impedance of the element, the measurement of the transducer's admittance can be exploited to assess the element's health. In the study presented in this paper, we created a 3D finite element model to mimic a transducer bonded to the abutment of a dental implant placed in a host bone site. We simulate…

Finite element methodAdmittanceMaterials scienceDental implantAcousticsmedicine.medical_treatmentFinite Element AnalysisBiophysicsBiomedical EngineeringBone and BonesOsseointegrationOsseointegrationElastic ModulusElectric ImpedancemedicineOrthopedics and Sports MedicineDental implantDental ImplantsElectromechanical impedance methodDental stabilityRehabilitationMechanical impedanceModels TheoreticalPiezoelectricityFinite element methodTransducerBiophysicAbutment (dentistry)Biomedical engineering
researchProduct

Improvement of Hall Effect Current Transducer Metrological Performances in the Presence of Harmonic Distortion

2010

The performance of Hall effect current transducers (HECTs), under distorted waveform conditions, is usually characterized by means of a frequency response test. In this paper, it was investigated if frequency response is able to correctly evaluate the ratio and the phase errors under distorted conditions. Two HECTs, with the accuracy class level of 1% and 0.5%, respectively, were experimentally characterized under two conditions: 1) sinusoidal excitation with frequencies ranging from 50 to 750 Hz, which is the well-known frequency response test, and 2) nonsinusoidal excitation using fundamental frequency and one harmonic with adjusted amplitude and phase shift. It was found that ratio and p…

Frequency responseElectric current measurementCurrent measurement current transducer frequency response hall effect devices harmonic distortion power system harmonics.AcousticsTransducersPhase (waves)GyratorsNon-sinusoidal excitationHarmonic distortionAccuracy levelFundamental frequenciesHarmonic analysisPhase errorElectric currentsError compensationFrequency responseFrequency response testsWaveformSinusoidal excitationsPhase shiftElectrical and Electronic EngineeringInstrumentationPhysicsTotal harmonic distortionElectric power distributionHall effectCurrent measurementsMetrological performanceCurrent transducerFundamental frequencyLight measurementAmplitudeAccuracy classHarmonicsMagnetic field effectsHarmonicHarmonic amplitudeSettore ING-INF/07 - Misure Elettriche E ElettronicheDistorted waveformsHarmonic componentsHall effect devicesIEEE Transactions on Instrumentation and Measurement
researchProduct

Rogowski coil current transducer compensation method for harmonic active power error

2015

Abstract In the harmonic active power measurement, the highest uncertainties are generally introduced by the current and voltage transducers. In a previous paper, the authors showed that the current transformer (CT) can introduce significant errors in such measurement, especially if the phase shift between voltage and current is close to ±90°. In such condition the errors on harmonic power measurement are mainly due to the CT phase displacement. This paper shows that better results can be achieved with more linear transducers, such as the Rogowski coil current transducers (RCCTs), whose metrological performance in distorted condition can be improved, by means of a proper compensation method…

Frequency responseEngineeringbusiness.industryApplied MathematicsAcousticsPower system harmonics Transducers Current transformers. Frequency response Power measurement Rogowski coilTransducersElectrical engineeringAC powerCondensed Matter PhysicsCurrent transformerRogowski coilCompensation (engineering)Power (physics)Current transformersFrequency responseHarmonicPower system harmonicsElectrical and Electronic EngineeringPower measurementbusinessInstrumentationSettore ING-INF/07 - Misure Elettriche E ElettronicheRogowski coilVoltage
researchProduct

Characterization of clamp-on current transformers under nonsinusoidal conditions

2009

This paper reports the performance of clamp-on current transformers under nonsinusoidal conditions. A set of experimental measurements helped to determine the ratio and the phase errors under two conditions: 1) sinusoidal excitation with frequencies from 45 to 1000 Hz and 2) nonsinusoidal excitation using the fundamental frequency and one harmonic, with adjusted phase shift. It was found that ratio and phase errors are affected by the phase angle between the harmonic and the fundamental and the harmonic amplitude. The effects of conductor location in the current transformer's window and of the air-gap width were also investigated. It was concluded that harmonic phase and ratio errors measur…

Frequency responseMaterials scienceElectric current measurementTransductorAcousticsErrorsTransducersPhase (waves)Energy Engineering and Power TechnologyClamp-on current transformers current transformers (CTs) frequency response power system harmonics transducers.Power transformersDistributed power generationElectric power systemsHarmonic analysisElectric power transmission networksClamp-on current transformersCurrent transformersFrequency responsePower electronicsFrequency measurementElectronic engineeringElectrical and Electronic EngineeringElectrical conductorTomographyComputed tomographyElectric power distributionElectric transformersCircuit faultsFault currentsFundamental frequencyComputerized tomographyFourier seriesCurrent measurementCurrent transformerDiagnostic radiographyElectric instrument transformersElectric frequency measurementPower system harmonicsMedical imagingCurrent transformers (CTs)Air gap (plumbing)Power transmissionElectric network analysisExcitation
researchProduct

Frequency response of Measurement Current Transformers

2008

In this paper the frequency response of two CTs is experimentally evaluated in the range of 30-600 Hz. A theoretical analysis of CTs behavior has been developed by means of the equivalent circuit. It was shown, by an experimental test, that, for the frequency range analyzed, the transformer equivalent circuit is a valid tool for the evaluation of CT performances.

Frequency responseTotal harmonic distortionMaterials scienceTransducerlawPower system harmonicsElectronic engineeringEquivalent circuitIec standardsTransformerCurrent transformerHardware_LOGICDESIGNlaw.invention2008 IEEE Instrumentation and Measurement Technology Conference
researchProduct

Targeting the JAK/STAT Pathway: A Combined Ligand- and Target-Based Approach

2021

Janus kinases (JAKs) are a family of proinflammatory enzymes able to mediate the immune responses and the inflammatory cascade by modulating multiple cytokine expressions as well as various growth factors. In the present study, the inhibition of the JAK-signal transducer and activator of transcription (STAT) signaling pathway is explored as a potential strategy for treating autoimmune and inflammatory disorders. A computationally driven approach aimed at identifying novel JAK inhibitors based on molecular topology, docking, and molecular dynamics simulations was carried out. For the best candidates selected, the inhibitory activity against JAK2 was evaluated in vitro. Two hit compounds with…

General Chemical EngineeringTransducersBioinformatics and computational biology Inhibitors Inhibition Peptides and proteins MoleculesLibrary and Information SciencesLigands01 natural sciencesstatArticleProinflammatory cytokine0103 physical sciencesProtein Kinase InhibitorsJanus KinasesTofacitinib010304 chemical physicsActivator (genetics)ChemistryJAK-STAT signaling pathwayGeneral Chemistry0104 chemical sciencesComputer Science ApplicationsCell biology010404 medicinal & biomolecular chemistryDocking (molecular)Signal transductionJanus kinaseSignal TransductionJournal of Chemical Information and Modeling
researchProduct