Search results for "transfemoral"

showing 4 items of 4 documents

Symmetry function in gait pattern analysis in patients after unilateral transfemoral amputation using a mechanical or microprocessor prosthetic knee

2021

AbstractBackgroundAbove-knee amputations (AKAs) contribute to gait asymmetry. The level of asymmetry is affected by the type of knee prosthetic module. There is limited evidence suggesting that more technically advanced solutions (microprocessor modules; MicPK) are superior to less advanced ones (mechanical modules; MechPK). The study aimed to evaluate the variable range of hip and pelvic joint movements during gait and look for differentiating areas with an increased level of asymmetry of the gait cycle in individuals who underwent an AKA and are equipped with MicPK or MechPK.MethodsTwenty-eight individuals participated in the study; 14 were assigned to a study group of individuals who und…

AdultMale030506 rehabilitationmedicine.medical_specialtyKnee Jointmedicine.medical_treatmentArtificial LimbsHealth InformaticsThighAmputation SurgicalPelvislcsh:RC321-57103 medical and health sciences0302 clinical medicinePhysical medicine and rehabilitationGait (human)MicrocomputersHumansMedicineSymmetry functionBiomechanicsRange of Motion ArticularTransfemoral amputationGaitlcsh:Neurosciences. Biological psychiatry. NeuropsychiatryRehabilitationbusiness.industryResearchRehabilitationBiomechanicsMiddle AgedSagittal planeBiomechanical Phenomenamedicine.anatomical_structureAmputationCoronal planeGait analysisFemaleHip JointGait analysis0305 other medical sciencebusiness030217 neurology & neurosurgeryJournal of NeuroEngineering and Rehabilitation
researchProduct

Temporal Trends in Transcatheter Aortic Valve Replacement in France

2017

Background - Transcatheter aortic valve replacement (TAVR) is standard therapy for patients with severe aortic stenosis who are at high surgical risk. However, national data regarding procedural characteristics and clinical outcomes over time are limited. Objectives - The aim of this study was to assess nationwide performance trends and clinical outcomes of TAVR during a 6-year period. Methods - TAVRs performed in 48 centers across France between January 2013 and December 2015 were prospectively included in the FRANCE TAVI (French Transcatheter Aortic Valve Implantation) registry. Findings were further compared with those reported from the FRANCE 2 (French Aortic National CoreValve and Edwa…

Aortic valvemedicine.medical_specialtymedicine.medical_treatmentnational registry030204 cardiovascular system & hematologyoutcomes03 medical and health sciences0302 clinical medicineValve replacementCardiac tamponadeMedicine030212 general & internal medicineComputingMilieux_MISCELLANEOUSAortic dissectionbusiness.industryMortality ratetransfemoralEuroSCORE[ SDV.MHEP.CSC ] Life Sciences [q-bio]/Human health and pathology/Cardiology and cardiovascular systemmedicine.diseasepacemaker3. Good healthSurgeryStenosisCathetermedicine.anatomical_structureCardiology and Cardiovascular Medicinebusiness
researchProduct

Biomechanical analysis of two types of osseointegrated transfemoral prosthesis

2020

In the last two decades, osseointegrated prostheses have been shown to be a good alternative for lower limb amputees experiencing complications in using a traditional socket-type prosthesis

Computer sciencemedicine.medical_treatmentFinite element analysi0206 medical engineeringOPLProsthetic limb02 engineering and technologyProsthesislcsh:TechnologyOsseointegrationlcsh:Chemistry03 medical and health sciencesDistal femur0302 clinical medicineosseointegrated prosthesismedicineGeneral Materials ScienceCADOPL osseointegrated prosthesiSettore ING-IND/15 - Disegno E Metodi Dell'Ingegneria IndustrialeInstrumentationlcsh:QH301-705.5Fluid Flow and Transfer ProcessesOrthodontics030222 orthopedicslcsh:TProcess Chemistry and TechnologyGeneral EngineeringFinite element analysisOPL osseointegrated prosthesisLimitingStress distributionTransfemoral amputeeequipment and supplies020601 biomedical engineeringTransfemoral prosthesislcsh:QC1-999OPRAComputer Science Applicationsbody regionslcsh:Biology (General)lcsh:QD1-999lcsh:TA1-2040Implantlcsh:Engineering (General). Civil engineering (General)lcsh:Physics
researchProduct

Longitudinal Gait Analysis of a Transfemoral Amputee Patient: Single-Case Report from Socket-Type to Osseointegrated Prosthesis

2023

The aim of the present case report was to provide a longitudinal functional assessment of a patient with transfemoral amputation from the preoperative status with socket-type prosthesis to one year after the osseointegration surgery. A 44 years-old male patient was scheduled for osseointegration surgery 17 years after transfemoral amputation. Gait analysis was performed through 15 wearable inertial sensors (MTw Awinda, Xsens) before surgery (patient wearing his standard socket-type prosthesis) and at 3-, 6-, and 12-month follow-ups after osseointegration. ANOVA in Statistical Parametric Mapping was used to assess the changes in amputee and sound limb hip and pelvis kinematics. The gait symm…

transfemoral amputation; osseointegration; socket-type; biomechanics; wearable sensors; gait analysis; gait symmetry; case reportElectrical and Electronic EngineeringSettore ING-IND/15 - Disegno E Metodi Dell'Ingegneria IndustrialeBiochemistryInstrumentationbiomechanics case report gait analysis gait symmetry osseointegration socket-type transfemoral amputation wearable sensorsAtomic and Molecular Physics and OpticsAnalytical ChemistrySensors
researchProduct