Search results for "transfer function"

showing 10 items of 152 documents

Quantitative Transfer Function Approaches in Palaeoclimatic Reconstruction Using Quaternary Ostracods

2012

Abstract Quantifying (palaeo-)environmental changes is a key challenge for aquatic biological proxies, but the number of published transfer functions is increasing rapidly for the main palaeoecologically relevant groups such as diatoms and chironomids, and several transfer functions have also been developed during the past decades based on ostracod findings. The main environmental variables influencing the species assemblage composition in ostracod training sets are specific ion concentrations or ratios, salinity, water temperature and/or water depth. The available transfer functions and training sets are globally scattered, but often regionally restricted in their application. The most com…

Water depthPaleontologybiologyCalibration (statistics)Water temperatureOstracodPartial least squares regressionQuaternarybiology.organism_classificationTransfer functionGeology
researchProduct

Development and analysis of the Soil Water Infiltration Global database

2018

27 Pags.- 11 Tabls.- 8 Figs. © Author(s) 2018. This work is distributed under the Creative Commons Attribution 4.0 License.

Condutividade Hidráulica[SDV]Life Sciences [q-bio]0208 environmental biotechnology02 engineering and technologySilt910computer.software_genreSoilRING INFILTROMETERS900 Geschichte und Geografie::910 Geografie Reisen::910 Geografie ReisenHydraulic conductivityELECTRICAL-CONDUCTIVITYAgricultural landddc:550Meteorology & Atmospheric SciencesSATURATED HYDRAULIC CONDUCTIVITYGeosciences Multidisciplinarydatabaselcsh:Environmental sciences2. Zero hungerlcsh:GE1-350DatabaseIN-SITUlcsh:QE1-996.5Geology04 agricultural and veterinary sciencesPE&RCPedo-transfer functions6. Clean waterInfiltration (hydrology)HYDROPHYSICAL PARAMETERS[SDE]Environmental SciencesPhysical SciencesINFILTRATION GLOBAL DATABASEHidrologiaHydraulic conductivityPHYSICAL-PROPERTIESSANDY SOILTENSION INFILTROMETEREcology and EnvironmentPedotransfer functionPEDOTRANSFER FUNCTIONSLife ScienceSOIL INFILTRATION MEASUREMENTSLand surface modelsInfiltration (hydrology)Soil Water Infiltration Global databaseANALYSIS OF THE SOIL WATERScience & TechnologyLand useInfiltration15. Life on land020801 environmental engineeringInfiltraçãolcsh:GeologySoloInfiltration Land surface models Land use Pedo-transfer functionsSWIGAgriculture and Soil ScienceData qualityITC-ISI-JOURNAL-ARTICLEEarth and Environmental SciencesINFILTROMETER MEASUREMENTSLand useSoil water040103 agronomy & agriculture0401 agriculture forestry and fisheriesGeneral Earth and Planetary SciencesEnvironmental scienceHydrologyITC-GOLDcomputer
researchProduct

To Assess the Validity of the Transfer Function Method: A Neural Model for the Optimal Choice of Conduction Transfer Functions

2010

This paper presents a new mathematical approach applied to the Conduction Transfer Functions (CTFs) of a multilayered wall to predict the reliability of building simula- tions based upon them. Such a procedure can be used to develop a decision support system that identifies the best condition to calculate the best CTFs set. This is a critical point at the core of ASHRAE calculation methodology founded on the Transfer Function Method (TFM). To evaluate the perfor- mance of different CTFs sets, the authors built a large amount of data, subsequently employed to train a Neural Network Classifier (NNC) able to predict the reliability of a simulation without performing it. For this purpose all th…

Building simulationSettore ING-IND/11 - Fisica Tecnica AmbientaleTransfer Function MethodNeural network
researchProduct

Imaging quality of multifocal intraocular lenses: automated assessment setup

2012

[EN] Purpose: A new technique for the assessment of the optical quality of multifocal intraocular lenses (MIOLs) under monochromatic and polychromatic illumination is presented. Methods: The system provides, in a totally automated procedure, the modulation transfer function (MTF) of the lens under test for different axial positions of the object. The artificial eye admits different artificial corneas, to optimise the axial resolution in the sampling of the MTF of the MIOL under test, and different pupils, to test the dependence of the optical performance of the MIOL on the eye pupil diameter. Results: The performance and sensitivity of the apparatus is tested with different commercial MIOLs…

Models AnatomicOptics and Photonicsbusiness.product_categorygenetic structuresComputer scienceImaging qualityIntraocular lenseslaw.inventionOpticsSampling (signal processing)Through-focus MTFlawOptical transfer functionHumansComputer visionSensitivity (control systems)Multifocal lensesLightingLenses IntraocularOptical setupbusiness.industryMultifocal intraocular lensMultifocal lenseseye diseasesSensory SystemsLens (optics)OphthalmologyImaging qualityFISICA APLICADAsense organsArtificial intelligenceMonochromatic colorbusinessOptometry
researchProduct

Optical and Visual Quality of the Visian Implantable Collamer Lens Using an Adaptive-Optics Visual Simulator

2013

To evaluate visual and optical quality of the implantable collamer lens for different powers and sizes of incision surgery.Prospective study in humans.An adaptive optics visual simulator was used to measure 3 powers of implantable collamer lenses and simulate the implantable collamer lens wavefront aberration's pattern for small- and large-incision surgery. Visual acuity (VA) and contrast sensitivity were measured in 11 observers for 3- and 5-mm pupils. Modulation transfer function, point spread function, and Strehl ratio were calculated.At 3 mm pupil, no statistically significant differences were found between both incision sizes for any implantable collamer lens power, except for -15 diop…

AdultMicrosurgeryOptics and PhotonicsPhakic Intraocular LensesVisual acuityAdolescentgenetic structuresComputer sciencemedia_common.quotation_subjectVisual AcuityPhakic intraocular lensPupilYoung AdultLens Implantation IntraocularOptical transfer functionmedicineHumansContrast (vision)Prospective StudiesAdaptive opticsVision OcularSimulationDioptremedia_commonAberrometryStrehl ratioeye diseasesRefractive Surgical ProceduresOphthalmologysense organsmedicine.symptomAmerican Journal of Ophthalmology
researchProduct

Reduction of the spherical aberration effect in high-numerical-aperture optical scanning instruments.

2006

In modern high-numerical-aperture (NA) optical scanning instruments, such as scanning microscopes, optical data storage systems, or laser trapping technology, the beam emerging from the high-NA objective focuses deeply through an interface between two media of different refractive index. Such a refractive index mismatch introduces an important amount of spherical aberration, which increases dynamically when scanning at increasing depths. This effect strongly degrades the instrument performance. Although in the past few years many different techniques have been reported to reduce the spherical aberration effect, no optimum solution has been found. Here we concentrate on a technique whose mai…

Materials scienceContrast transfer functionAperturebusiness.industryAstrophysics::Instrumentation and Methods for AstrophysicsComa (optics)Optical storageAtomic and Molecular Physics and OpticsElectronic Optical and Magnetic MaterialsNumerical apertureSpherical aberrationOpticsComputer Vision and Pattern RecognitionbusinessAdaptive opticsOptical aberrationJournal of the Optical Society of America. A, Optics, image science, and vision
researchProduct

Imaging Quality of Bifocal Piggyback Intraocular Lens versus ReSTOR and TECNIS Multifocal Lenses

2009

Purpose The imaging quality provided by a piggyback integrated by a monofocal intraocular lens (IOL) + a bifocal IOL of zero power and +3.75 diopters of addition is compared with the optics quality of a simple multifocal IOL of the same power and addition. Methods The imaging quality was evaluated by determining the modulation transfer function (MTF), using an artificial eye simulating in vivo conditions of the anterior chamber, including an artificial cornea and a wet cell containing physiologic solution where the IOL was positioned. The MTFs of the bifocal piggyback for near and distance vision were measured, with pupil diameters of 3 and 5 mm, and compared with the MTFs of an equivalent …

Artificial corneaOptics and Photonicsmedicine.medical_specialtybusiness.product_categoryMaterials sciencemedicine.medical_treatmentVisual AcuityIntraocular lensEyeRefraction OcularPupil03 medical and health sciences0302 clinical medicineOptical transfer functionOphthalmologymedicineHumansMultifocal lensesDioptreLenses IntraocularDepth PerceptionStrehl ratioGeneral MedicineModels TheoreticalOphthalmologyImaging quality030221 ophthalmology & optometryArtificial Organsbusiness030217 neurology & neurosurgeryEuropean Journal of Ophthalmology
researchProduct

A Trajectory-Driven 3D Channel Model for Human Activity Recognition

2021

This paper concerns the design, analysis, and simulation of a 3D non-stationary channel model fed with inertial measurement unit (IMU) data. The work in this paper provides a framework for simulating the micro-Doppler signatures of indoor channels for human activity recognition by using radiofrequency-based sensing technologies. The major human body segments, such as wrists, ankles, torso, and head, are modelled as a cluster of moving point scatterers. We provide expressions for the time variant (TV) speed and TV angles of motion based on 3D trajectories of the moving person. Moreover, we present mathematical expressions for the TV Doppler shifts and TV path gains associated with each movin…

Channel transfer functionGeneral Computer ScienceComputer scienceInternet of ThingsComputació centrada en humansDoppler EfecteActivity recognitionsymbols.namesakespectrogramInertial measurement unitVDP::Teknologi: 500::Medisinsk teknologi: 620Channel measurementsnon-stationary fading channelsmedicineGeneral Materials ScienceComputer visionNon-stationary fading channelsReconeixement de formes (Informàtica)channel state informationSpectrogrambusiness.industryWireless sensingGeneral Engineering:Enginyeria de la telecomunicació::Processament del senyal::Reconeixement de formes [Àrees temàtiques de la UPC]TorsoInertial measurement unitsExpression (mathematics)TK1-9971Time-variant Doppler power characteristicsmedicine.anatomical_structureChannel state informationHuman-centered computingchannel transfer functiontime-variant Doppler power characteristicsTrajectorysymbolsChannel state informationSpectrogramMicro-Doppler signature:Informàtica::Intel·ligència artificial [Àrees temàtiques de la UPC]Electrical engineering. Electronics. Nuclear engineeringArtificial intelligenceHuman activity recognitionbusinessDoppler effect
researchProduct

In vitro optical performance of a new aberration-free intraocular lens

2014

To assess the optical performance of the new EnVista intraocular lens (IOL). Four aspheric IOLs were evaluated; the new EnVista is one amoung them. This IOL, similarly to the Z-Flex HB and the Bi-Flex 1.8 667AB ones, has a neutral aspheric design, whereas the fourth IOL under test (AcrySof IQ IOL SN60WF) presents a negative spherical aberration (SA). The IOL’s aberration patterns were measured in vitro, by setting them up on an optical bench. From these aberration-pattern data, the modulation transfer function (MTF), the average modulation values, and the points spread function (PSF) were calculated. Furthermore, in order to assess the potential optical quality that these IOLs would yield o…

WavefrontLenses Intraocularmedicine.medical_specialtyOptics and PhotonicsMaterials scienceCorneal Wavefront Aberrationgenetic structuresmedicine.medical_treatmentIntraocular lensequipment and suppliesProsthesis Designeye diseasesOptical qualityOphthalmologySpherical aberrationmedicine.anatomical_structureCorneaOphthalmologyOptical transfer functionLaboratory StudymedicineProsthesis designHumanssense organsCorneal Wavefront Aberration
researchProduct

Determining hydraulic properties of a loam soil by alternative infiltrometer techniques

2015

Testing infiltrometer techniques to determine soil hydraulic properties is necessary for specific soils. For a loam soil, the water retention and hydraulic conductivity predicted by the BEST (Beerkan Estimation of Soil Transfer parameters) procedure of soil hydraulic characterization was compared with data collected by more standard laboratory and field techniques. Six infiltrometer techniques were also compared in terms of saturated soil hydraulic conductivity, Ks. BEST yielded water retention values statistically similar to those obtained in the laboratory and Ks values practically coinciding with those determined in the field with the pressure infiltrometer (PI). The unsaturated soil hyd…

0208 environmental biotechnologySoil science04 agricultural and veterinary sciences02 engineering and technology020801 environmental engineeringWater retentionInfiltration (hydrology)Hydraulic conductivityPedotransfer functionLoamSoil water040103 agronomy & agriculturemedicine0401 agriculture forestry and fisheriesGeotechnical engineeringInfiltrometermedicine.symptomSaturation (chemistry)GeologyWater Science and TechnologyHydrological Processes
researchProduct