Search results for "trap"

showing 10 items of 2144 documents

Environmental and food applications of LC-tandem mass spectrometry in pesticide-residue analysis: An overview

2003

An overview is given on pesticide-residue determination in environmental and food samples by liquid chromatography/mass spectrometry/mass spectrometry (LC/MS/MS). Pesticides comprise a large number of substances that belong to many completely different chemical groups, the only common characteristic is that they are effective against pests. They still constitute a challenge in MS because there is no collective pathway for fragmentation. A brief introduction to the theory of tandem MS permits a discussion of which parameters influence the ionization efficiency when the ions are subjected to different actions. Emphasis is placed on the different tandem MS instruments: triple and ion-trap quad…

Detection limitChromatographyPesticide residueTandemChemistryCondensed Matter PhysicsTandem mass spectrometryMass spectrometryGeneral Biochemistry Genetics and Molecular BiologyAnalytical ChemistrySample preparationQuadrupole ion trapTime-of-flight mass spectrometrySpectroscopyMass Spectrometry Reviews
researchProduct

Direct analysis in real-time high-resolution mass spectrometry as a valuable tool for polyphenols profiling in olive oil

2018

A fast and reliable method to characterize the polyphenolic compound profiles in extra virgin olive oil (EVOO) has been developed using direct analysis in real time (DART) and linear ion-trap Orbitrap mass spectrometry (LTQ-Orbitrap-MS). Hydroalcoholic extraction increased speed and reduced matrix effects, and DART-MS/MS ensured accurate analysis. Characterization of polyphenol fingerprinting in EVOO samples takes 2 min. This method exhibited proper linearity (R2 ≥ 0.99) in the range of 5–2500 μg g−1, limit of detection (LOD) of 1.5 μg g−1 (signal-to noise S/N = 3), and limits of quantitation (LOQs) of 5 μg g−1 (S/N = 10) for resveratrol (a polyphenol not detected in olive oil). Six spiked …

Detection limitDartChromatographyChemistryGeneral Chemical Engineering010401 analytical chemistryGeneral Engineering02 engineering and technology021001 nanoscience & nanotechnologyOrbitrapMass spectrometry01 natural sciencesDART ion source0104 chemical sciencesAnalytical Chemistrylaw.inventionlawPolyphenolPrincipal component analysis0210 nano-technologycomputerOlive oilcomputer.programming_language
researchProduct

Determination of glyphosate and aminomethylphosphonic acid in natural water using the capillary electrophoresis combined with enrichment step

2005

A previously elaborated capillary electrophoresis (CE) method used for the determination of glyphosate and aminomethylphosphonic acid (AMPA) was slightly modified in order to improve the sensitivity. However, detection limits attained (5 μg mL−1 for glyphosate and 4 μg mL−1 for AMPA) were still not satisfactory for analytical purposes, thus the addition of a preconcentration step before the CE analysis was proposed. AMBERLITE®IRA-900, a strong anion-exchange resin, was used to preconcentrate both analytes in environmental aqueous samples. The experimental conditions optimised in a previous work were readapted, by decreasing the eluent concentration due to CE limitations. Satisfactory result…

Detection limitaminomethylphosphonic acid (AMPA)Chromatographyanion-exchange resinsChemistrycapillary electrophoresisBiochemistryHigh-performance liquid chromatographyAnalytical Chemistrychemistry.chemical_compoundColumn chromatographyCapillary electrophoresisglyphosateGlyphosateenvironmental analysisUltrapure waterEnvironmental ChemistryAminomethylphosphonic acidSample preparationHPLCSpectroscopyAnalytica Chimica Acta
researchProduct

Online atmospheric pressure chemical ionization ion trap mass spectrometry (APCI-IT-MS<sup>n</sup>) for measuring organic…

2012

Abstract. The field application of an aerosol concentrator in conjunction with an atmospheric pressure chemical ionization ion trap mass spectrometer (APCI-IT-MS) at the boreal forest station SMEAR II at Hyytiälä, Finland, is demonstrated in this study. APCI is a soft-ionization technique allowing online measurements of organic acids in the gas and particle phase. The detection limit for the acid species in the particle phase was improved by a factor of 7.5 to 11 (e.g. ∼40 ng m3 for pinonic acid) by using the miniature versatile aerosol concentration enrichment system (mVACES) upstream of the mass spectrometer. The APCI-IT-MS was calibrated in the negative ion mode with two biogenic organic…

Detection limitchemistry.chemical_classificationAtmospheric Science010504 meteorology & atmospheric sciencesChemistryAnalytical chemistryAtmospheric-pressure chemical ionization010501 environmental sciencesMass spectrometry01 natural sciencesAerosolIon13. Climate actionIon trapElectron ionization0105 earth and related environmental sciencesOrganic acidAtmospheric Measurement Techniques
researchProduct

Active alkaline traps to determine acidic-gas ratios in volcanic plumes: Sampling techniques and analytical methods

2014

In situ measurements have been the basis for monitoring volcanic gas emissions for many years and—being complemented by remote sensing techniques—still play an important role to date. Con- cerning in situ techniques for sampling a dilute plume, an increase in accuracy and a reduction of detection limits are still necessary for most gases (e.g., CO2, SO2, HCl, HF, HBr, HI). In this work, the Raschig-Tube tech- nique (RT) is modified and utilized for application on volcanic plumes. The theoretical and experimental absorption properties of the RT and the Drechsel bottle (DB) setups are characterized and both are applied simultaneously to the well-established Filter packs technique (FP) in the …

Detection limitgeographyAnalytegeography.geographical_feature_categoryalkaline traps plume sampling sulfur and halogen Etna volcanoDifferential optical absorption spectroscopyIon chromatographyMineralogySettore GEO/08 - Geochimica E VulcanologiaPlumeGeophysicsVolcanoGeochemistry and PetrologyAbsorption (electromagnetic radiation)Inductively coupled plasma mass spectrometryGeologyGeochemistry, Geophysics, Geosystems
researchProduct

Mast cells promote homeostasis by limiting endothelin-1-induced toxicity

2004

Endothelin-1 (ET-1) is a 21-amino-acid peptide, derived from vascular endothelial cells, with potent vasoconstrictor activity. ET-1 has been implicated in diverse physiological or pathological processes, including the vascular changes associated with sepsis. However, the factors that regulate ET-1-associated toxicity during bacterial infections, or in other settings, are not fully understood. Both the pathology associated with certain allergic and autoimmune disorders, and optimal host defence against bacterial and parasitic infections are mediated by mast cells. In vitro, mast cells can produce ET-1 (ref. 11), undergo ET-1-dependent and endothelin-A receptor (ET(A))-dependent activation, a…

DiarrheaProteasesDrug-Related Side Effects and Adverse ReactionsCell SurvivalPeritonitisBiologyPeptides CyclicCell DegranulationBody TemperatureMiceChymasesIn vivomedicineAnimalsHomeostasisMast CellsReceptorEgtazic AcidMice KnockoutMultidisciplinaryEndothelin-1Stem CellsBody WeightSerine EndopeptidasesEndogenous mediatorMast cellEndothelin 1In vitroCell biologyMice Inbred C57BLSurvival RateProto-Oncogene Proteins c-kitmedicine.anatomical_structureMutationImmunologyFemaleOligopeptidesInjections IntraperitonealHomeostasisNature
researchProduct

Innovative and Applied Research in Biology: Proceedings

2022

The collection contains SCIENTIFIC articles on the topics of the LU 80 conference reports. The main focus is on innovative and applied research in biology and interdisciplinary fields.

DiatomsRed beetroot juiceLow frequency electromagnetic radiationEU habitatsRare and threatened speciesArtificial lightCloudberry:NATURAL SCIENCES::Biology [Research Subject Categories]Pest controlYellow sticky trapsSpecially protected whorl snails (Vertigo spp.)Aquatic pollutionPoint mutationsBioindicatorsGlutathione peroxidaseGreenhouse whitefliesDuckweed Lemna minorThe Daugava RiverPro/antioxidative actionChlorophyll fluorescenceNature protectionSpecific Pollution Sensitivity Index (IPS)
researchProduct

Extension of the Applicability of Jäntti's Method to the Fast Calculation of Desorption Data

2000

The time for sorption measurements may be reduced substantially by measuring several values at short time intervals at the beginning of a kinetic curve and extrapolating them to the equilibrium value. The method used by Jäntti for simple adsorption processes has been extended to complicated processes described by a second-order differential equation. A simulated example is provided.

Differential equationChemistryGeneral Chemical EngineeringExtrapolationlcsh:QD450-801ThermodynamicsSorptionlcsh:Physical and theoretical chemistrySurfaces and InterfacesGeneral ChemistryExtension (predicate logic)MechanicsAdsorptionDesorptionKinetic curveGravimetric analysisAdsorption Science & Technology
researchProduct

Single-Crystal X-Ray Diffraction Study of Pressure and Temperature-Induced Spin Trapping in a Bistable Iron(II) Hofmann Framework.

2020

High-pressure single-crystal X-ray diffraction has been used to trap both the low-spin (LS) and high-spin (HS) states of the iron(II) Hofmann spin crossover framework, [FeII (pdm)(H2 O)[Ag(CN)2 ]2 ⋅H2 O, under identical experimental conditions, allowing the structural changes arising from the spin-transition to be deconvoluted from previously reported thermal effects.

DiffractionMaterials scienceBistabilitySpin trapping010405 organic chemistryGeneral MedicineGeneral Chemistry010402 general chemistry01 natural sciencesTemperature inducedMolecular physicsCatalysis0104 chemical sciencesSpin crossoverThermalX-ray crystallographyCondensed Matter::Strongly Correlated ElectronsSingle crystalAngewandte Chemie (International ed. in English)
researchProduct

Small-x, Diffraction and Vector Mesons

2015

This talk discusses recent progress in some topics relevant for deep inelastic scattering at small x. We discuss first differences and similarities between conventional collinear factorization and the dipole picture of deep inelastic scattering. Many of the recent theoretical advances at small x are related to taking calculations in the nonlinear saturation regime to next-to-leading order accuracy in the QCD coupling. On the experimental side significant recent progress has been made in exclusive and diffractive processes, in particular in ultraperipheral nucleus-nucleus collisions.

DiffractionParticle physicsMesonNuclear TheoryeducationFOS: Physical sciences114 Physical sciences01 natural sciencesNuclear Theory (nucl-th)next-to-leading order accuracycollinear factorizationHigh Energy Physics - Phenomenology (hep-ph)Factorizationdeep inelastic scattering0103 physical sciencesNonlinear saturation010306 general physicsCouplingQuantum chromodynamicsPhysicsultraperipheral collisionsdipole picture010308 nuclear & particles physicsDeep inelastic scatteringDipoleHigh Energy Physics - Phenomenologysmall x
researchProduct