Search results for "tunne"
showing 10 items of 739 documents
A Contradiction between Pulsed and Steady-State Studies in the Recombination Kinetics of Close Frenkel Defects in KBr and KCl Crystals
1994
Theoretical study of the kinetics of the correlated annealing of pairs of close (geminate) F-H centers in KCl and KBr crystals controlled by their diffusion and elastic attraction shows that the multi-step (kink) decay in defect concentrations observed more than once in thermostimulated experiments takes place only for very close F-H center pairs which are no further than fourth nearest neighbors. On the other hand, it is demonstrated (both theoretically and experimentally) that such F-H center pairs should be destroyed by the tunneling recombination already at time ≤10 -4 s, i.e. much before beginning of the thermostimulated experiments. Possible explanations of this contradiction are sugg…
A Wind Tunnel and Theoretical Study of the Melting Behavior of Atmospheric Ice Particles. IV: Experiment and Theory for Snow Flakes
1990
Abstract An experiment in the Mainz vertical Cloud Tunnel is described in which natural and laboratory-made aggregates of snow crystals (snow flakes) were melted under free fall conditions in the vertical air stream of the tunnel, which was allowed to warm up at the rates experienced by falling snow flakes in the atmosphere. The variation of the fall mode, the fall velocity, and the percentage of ice melted, as a function of percentage of distance travelled for 99% melting was recorded by cinematography. The laboratory results were confirmed by the results of a theoretical heat transfer model which we developed for the melting of a snow flake. In this model a snow flake was idealized by an …
Design, construction and commissioning of the Braunschweig Icing Wind Tunnel
2018
Beyond its physical importance in both fundamental and climate research, atmospheric icing is considered as a severe operational condition in many engineering applications like aviation, electrical power transmission and wind-energy production. To reproduce such icing conditions in a laboratory environment, icing wind tunnels are frequently used. In this paper, a comprehensive overview on the design, construction and commissioning of the Braunschweig Icing Wind Tunnel is given. The tunnel features a test section of 0.5 m × 0.5 m with peak velocities of up to 40 m s−1. The static air temperature ranges from −25 to +30 °C. Supercooled droplet icing with liquid water contents up to 3 g m−3 c…
A Laboratory Dust Generator Applying Vibration to Soil Sample: Mineralogical Study and Compositional Analyses
2020
International audience; A laboratory study was carried out using a vibrating system (SyGAVib) to produce aerosols from four soils collected in the central Tunisian region around Sfax. The aim of this device is to mimic dust emission by natural wind erosion. Using compositional analysis, the dust produced was compared to (i) dust generated in a wind tunnel by the same soils, (ii) fine sieved and (iii) original bulk soils, and (iv) naturally occurring aerosol samples collected in the same area. The relative quartz content strongly decreases from bulk to fine soils, and again from fine soils to both wind tunnel and vibration‐generated aerosols. Compositional data analysis (CoDA) clearly shows …
Particle surface area dependence of mineral dust in immersion freezing mode: investigations with freely suspended drops in an acoustic levitator and …
2014
Abstract. The heterogeneous freezing temperatures of supercooled drops were measured using an acoustic levitator. This technique allows one to freely suspend single drops in the air without any wall contact. Heterogeneous nucleation by two types of illite (illite IMt1 and illite NX) and a montmorillonite sample was investigated in the immersion mode. Drops of 1 mm in radius were monitored by a video camera while cooled down to −28 °C to simulate freezing within the tropospheric temperature range. The surface temperature of the drops was contact-free, determined with an infrared thermometer; the onset of freezing was indicated by a sudden increase of the drop surface temperature. For compari…
Comparative study on immersion freezing utilizing single-droplet levitation methods
2021
Immersion freezing experiments were performed utilizing two distinct single-droplet levitation methods. In the Mainz vertical wind tunnel, supercooled droplets of 700 µm diameter were freely floated in a vertical airstream at constant temperatures ranging from −5 to −30 ∘C, where heterogeneous freezing takes place. These investigations under isothermal conditions allow the application of the stochastic approach to analyze and interpret the results in terms of the freezing or nucleation rate. In the Mainz acoustic levitator, 2 mm diameter drops were levitated while their temperature was continuously cooling from +20 to −28 ∘C by adapting to the ambient temperature. Therefore, in this case th…
The ice nucleating ability of pollen:
2002
Abstract Laboratory tests were conducted of the ice nucleating ability of four kinds of pollen in the immersion and the contact freezing modes. The diameters of the selected pollen were between 25 and 70 μm. The experiments were carried out at the Mainz vertical wind tunnel with freely suspended supercooled droplets at temperatures down to −28 °C. The immersion freezing experiments were conducted with drops of radii between 250 and 375 μm formed from distilled water with a defined amount of pollen added. The drops were freely floated in the wind tunnel while being supercooled. For the contact freezing experiments, a short burst of pollen was allowed to collide with freely suspended, superco…
A Wind Tunnel Study of Turbulence Effects on the Scavenging of Aerosol Particles by Water Drops
2001
Abstract Laboratory experiments are described where the effects of turbulence on the impaction scavenging of aerosol particles by water drops were investigated. During the experiments the drops were freely suspended at their terminal velocities in the Mainz vertical wind tunnel. Turbulence in the tunnel airstream was produced by placing a needle obstruction upstream of the floating drop. The energy dissipation rates e were between 0.03 and 0.5 m2 s−3. The power spectrum covered a range of k values between 102 and 3 × 103 m−1, agreeing with atmospheric observations within this range. Collector drops of 346-μm, 1.68-mm, and 2.88-mm radius were exposed to indium acetylacetonate aerosol particl…
An evaluation of the estimation of road traffic emission factors from tracer studies
2010
Road traffic emission factors (EFs) are one of the main sources of uncertainties in emission inventories; it is necessary to develop methods to reduce these uncertainties to manage air quality more efficiently. Recently an alternative method has been proposed to estimate the EFs. In that work the emission factors were estimated from a long term tracer study developed in Ho Chi Minh City (HCMC) Vietnam. A passive tracer was continuously emitted from a finite line source placed in one side of an urban street canyon. Simultaneously, the resulting tracer concentrations were monitored at the other side of the street. The results of this experiment were used to calculate the dispersion factors an…
Magnetic tunneling junctions with the Heusler compound
2005
Abstract Certain Heusler phases belong to the materials which are discussed as potential half metals. Here, results of tunneling experiments with the full-Heusler alloy Co 2 Cr 0.6 Fe 0.4 Al are presented. The Heusler alloy is used as an electrode of magnetic tunneling junctions. The junctions are deposited by magnetron DC sputtering using shadow mask techniques with AlO x as a barrier and cobalt as counter electrode. Measurements of the magnetoresistive differential conductivity in a temperature range between 4 and 300 K are shown. An analysis of the barrier properties applying the Simmons model to the bias dependent junction conductivity is performed. VSM measurements were carried out to …