Search results for "value"

showing 10 items of 5321 documents

Pulpal ischemia in man: effects on detection threshold, A-delta neural response and sharp dental pain

1999

— Preferential blocks of peripheral nerves have shown that myelinated nerves are more susceptible to local compression and less resistent to asphyxia than unmyelinated fibers. Since two groups of functionally different nociceptors exist in the dental pulp, it is of theoretical and clinical interest to determine the influence of ischemia on the sensitivity of human dental pulp, using standard means for testing tooth vitality and at the same time investigating the intensity coding in one pathway of the afferent trigeminal system. Adrenaline was used to study the differential effect of adrenaline-induced ischemia on intradental A-delta nerve activity (INA) and the concomitant sharp pain, as we…

AdultMaleHot TemperatureEpinephrineDental Pulp TestIschemiaSensory systemStimulationNerve Fibers MyelinatedSharp Painstomatognathic systemIschemiaPredictive Value of TestsmedicineHumansAnesthetics LocalDental PulpPain MeasurementAfferent PathwaysDentin Sensitivitybusiness.industryLidocaineNociceptorsTooth surfaceToothacheMiddle AgedAdequate stimulusmedicine.diseaseCold Temperaturestomatognathic diseasesSensory ThresholdsAnesthesiaNociceptorRegression AnalysisFemalePerceptionOral SurgerybusinessDental Traumatology
researchProduct

C- and Aδ-fiber components of heat-evoked cerebral potentials in healthy human subjects

1999

Feedback-controlled laser heat was used to stimulate the hairy skin of the hand dorsum and forearm, and heat-evoked cerebral potentials were recorded at midline (Fz, Cz, Pz) and temporal (T3, T4) scalp positions. Based on data from primary afferent electrophysiology a stimulus level (40 degrees C) was chosen, which is above C-fiber heat threshold, but clearly below A delta-nociceptor heat threshold in order to excite selectively C-fibers without concomitant excitation of A delta-fibers. Feedback-controlled stepped heat stimuli to 40 degrees C elicited ultralate laser evoked potentials (LEPs) at the vertex in a high proportion of experiments (90%). Estimates of conduction velocity calculated…

AdultMaleHot TemperatureLaser-Evoked PotentialsStimulus (physiology)Nerve conduction velocityFeedbackNerve FibersReference ValuesReaction TimeNoxious stimulusHumansEvoked potentialEvoked PotentialsSkinChemistryLasersBrainMiddle AgedElectrophysiologyAnesthesiology and Pain MedicineNociceptionNeurologyNociceptorFemaleNeurology (clinical)NeurosciencePain
researchProduct

Asymmetric metabolic profile in mesial temporal lobes: Localized H-1 MR spectroscopy in healthy right-handed and non-right-handed subjects

1996

International audience; Abstract: PURPOSE: To determine a possible asymmetric metabolic profile in right-handed and non-right-handed healthy subjects by comparing proton spectra from temporal lobes. MATERIALS AND METHODS: Twenty-eight healthy adults (17 right-handers, 11 non-right-handers) underwent magnetic resonance (MR) imaging and single-voxel MR spectroscopy. N-acetylaspartate (NAA), choline (Cho), and creatine (Cr) peak areas were measured. RESULTS: Volume of hippocampal formations was larger on the right in right-handers (right volume: 4.04 cm(3) +/- 0.67 vs left volume: 3.84 cm(3) +/- 0.62; P = .00004) and in non-right-handers (right volume: 4.22 cm(3) +/- 0.78 vs left volume: 4.05 …

AdultMaleIn vivo magnetic resonance spectroscopyspectroscopyMagnetic Resonance Spectroscopybrainvolume measurement[INFO.INFO-IM] Computer Science [cs]/Medical ImagingHippocampusHippocampal formationCreatineHippocampusFunctional Laterality030218 nuclear medicine & medical imagingTemporal lobe03 medical and health scienceschemistry.chemical_compound0302 clinical medicineNuclear magnetic resonanceReference Values[INFO.INFO-IM]Computer Science [cs]/Medical ImagingHumansMedicineRadiology Nuclear Medicine and imagingSex Characteristicsfunctionvolume[ INFO.INFO-IM ] Computer Science [cs]/Medical Imagingmedicine.diagnostic_testbusiness.industryMagnetic resonance imagingMagnetic Resonance ImagingTemporal LobeLobemedicine.anatomical_structurechemistryLateralityFemalebusinessNuclear medicinemetabolismmagnetic resonance (MR)030217 neurology & neurosurgery
researchProduct

Effect of sperm DNA fragmentation on pregnancy outcome depends on oocyte quality

2010

Objective To quantify the effect of sperm DNA fragmentation (SDF) on reproductive outcome by evaluating the most statistically significant bias factors using logistic regression. Design Prospective blind observational cohort study. Setting University affiliated private IVF unit. Patient(s) Two hundred ten male partners of couples undergoing in vitro fertilization (IVF) or first intracytoplasmic sperm injection (ICSI) cycles with fresh or thawed sperm with the women's own or donated oocytes. Intervention(s) None. Main Outcome Measure(s) SDF determined before and after swim-up (n = 420), odds ratio calculated of the effect of an increase of one unit of SDF on pregnancy, and stratified regress…

AdultMaleInfertilitymedicine.medical_specialtymedicine.medical_treatmentSemenDNA FragmentationFertilization in VitroBiologyIntracytoplasmic sperm injectionAndrologyHuman fertilizationPredictive Value of TestsPregnancymedicineHumansProspective StudiesFertilisationCryopreservationGynecologyPregnancyIn vitro fertilisationPregnancy OutcomeObstetrics and GynecologyPrognosismedicine.diseaseSpermatozoaSpermLogistic ModelsReproductive MedicineOocytesFemaleInfertility FemaleFertility and Sterility
researchProduct

Intracortical inhibition and facilitation in human facial motor area: difference between upper and lower facial area.

2001

Objective: To investigate the intracortical inhibitory and excitatory systems in the motor cortical representation of upper and lower facial muscles. Methods: Paired-pulse transcranial magnetic stimulation (TMS) was applied to 7 healthy volunteers, with the interstimulus interval (ISI) between the conditioning stimulus (CS) and test stimulus, varied from 1 to 20 ms. CS was set at 90% of motor threshold. Muscle evoked potentials (MEPs) were recorded from first dorsal interosseus (FDI), orbicularis oculi (o. oculi) and mentalis muscles. Result: TMS evoked MEPs in o. oculi on both ipsi- and contralateral sides in all subjects. In the paired-pulse study, MEP amplitude in the mentalis decreased …

AdultMaleIntracortical circuitmedicine.medical_treatmentFacial MusclesStimulus (physiology)MagneticsReference ValuesPhysiology (medical)medicineReaction TimeHumansInhibitionOrbicularis oculi muscleInterstimulus intervalMotor CortexMotor controlNeural InhibitionEvoked Potentials MotorSensory SystemsElectric StimulationTranscranial magnetic stimulationFacial muscleFacial musclesmedicine.anatomical_structureNeurologyMentalisFacilitationsense organsNeurology (clinical)PsychologyNeuroscienceTranscranial magnetic stimulationMotor cortexClinical neurophysiology : official journal of the International Federation of Clinical Neurophysiology
researchProduct

Falsely elevated intraocular pressure due to increased central corneal thickness

1999

PURPOSE: To evaluate whether ocular hypertensive subjects have a higher central corneal thickness than other individuals. METHODS: In this prospective study, 48 subjects with ocular hypertension, 63 patients with open-angle glaucoma, 56 nonglaucomatous patients with diabetes mellitus, and 106 control subjects were evaluated. Corneal thickness was measured by ultrasound pachymetry, and intraocular pressure was determined by Goldmann applanation tonometry. RESULTS: Central corneal thickness was significantly higher in the ocular hypertensive subjects, mean +/- S.D., 592+/-39 microm, than in the patients with glaucoma (536+/-34 microm), the nonglaucomatous patients with diabetes mellitus (550+…

AdultMaleIntraocular pressuremedicine.medical_specialtyprimary open-angle glaucomaAdolescentgenetic structuresEye diseaseOcular hypertensionGlaucomaCorneaCellular and Molecular NeurosciencePredictive Value of TestsCorneaOphthalmologyDiabetes mellitusHumansMedicineFalse Positive ReactionsProspective StudiesCorneal pachymetry[SDV.MHEP.OS]Life Sciences [q-bio]/Human health and pathology/Sensory OrgansProspective cohort studyAgedUltrasonographyAged 80 and overmedicine.diagnostic_testdiabetesbusiness.industryMiddle Agedmedicine.diseaseSensory Systemseye diseasesSurgeryOphthalmologymedicine.anatomical_structureocular hypertensionFemalecentral corneal thicknesssense organsbusinessGlaucoma Open-Angle[SDV.MHEP]Life Sciences [q-bio]/Human health and pathologyintraocular pressure
researchProduct

Evaluation of the anterior chamber angle in keratoconus and normal subjects.

2015

To evaluate the anterior chamber angle in keratoconus eyes by use of the Visante™ OCT and Orbscan™ II.Anterior chamber angle was measured with the Visante™ OCT and Orbscan™ II in 52 subjects, 26 KC subjects and 26 age and control subjects.When comparing the nasal and temporal angles obtained with the two techniques no correlation was found (R(2) always below 0.01) in either the control subjects or in the KC subjects. Despite this, there was an overall statistically significant difference in mean anterior chamber angles (p0.001) between Visante™ OCT and Orbscan™ II. There was no statistical difference (p0.05) between nasal and temporal anterior chamber angles when comparing controls and KC s…

AdultMaleKeratoconusmedicine.medical_specialtyKeratoconusSensitivity and SpecificityAnterior chamber angleAnterior Eye SegmentReference ValuesOphthalmologymedicineHumansOrbscan iiSlit Lampbusiness.industrySignificant differenceCorneal TopographyReproducibility of ResultsGeneral Medicinemedicine.diseaseControl subjectsOphthalmologyOptometryFemalebusinessTomography Optical CoherenceOptometryContact lensanterior eye : the journal of the British Contact Lens Association
researchProduct

Effects of a 21 days space flight on the mechanical performance and the EMG power spectrum of the leg muscles

2002

AdultMaleLegMaterials scienceElectromyographyWeightlessnessBiomedical EngineeringSpectral densitySignal Processing Computer-AssistedSpace Flightmaximal power; space fligth; microgravitySpaceflightmicrogravitylaw.inventionLeg musclespace fligthlawReference Valuesmaximal powerIsometric ContractionExercise TestHumansMuscle SkeletalSimulation
researchProduct

Associative and semantic priming effects occur at very short stimulus-onset asynchronies in lexical decision and naming

1997

Abstract Prior research has found significant associative/semantic priming effects at very short stimulus-onset asynchronies (SOAs) in experimental tasks such as lexical decision, but not in naming tasks (however, see Lukatela and Turvey, 1994 ). In this paper, the time course of associative priming effects was analyzed at several very short SOAs (33, 50, and 67 ms), using the masked priming paradigm ( Forster and Davis, 1984 ), both in lexical decision (Experiment 1) and naming (Experiment 2). The results show small—but significant—associative priming effects in both tasks. Additionally, using the masked priming procedure at the 67 ms SOA, Experiments 3 and 4, shows facilitatory priming ef…

AdultMaleLinguistics and LanguageCognitive NeuroscienceDecision MakingWord processingExperimental and Cognitive PsychologyLanguage and LinguisticsPsycholinguisticsReference ValuesReaction TimeDevelopmental and Educational PsychologyLexical decision taskHumansSemantic memoryAttentionResponse primingCognitionPaired-Associate LearningLinguisticsSemanticsMental RecallWord recognitionFemalePsychologyPriming (psychology)Cognitive psychologyCognition
researchProduct

Separate and Combined Effects of a Benzodiazepine (Alprazolam) and Noise on Auditory Brainstem Responses in Man

1999

Auditory brainstem responses (ABRs) were recorded in 60 male or female, anxious or anxiety-free university students, before and after separated or simultaneous intake of alprazolam and exposure to noise. A significant increase of the latencies of the ABRs was found when subjects took alprazolam. This effect is consistent with the presence of gamma-aminobutyric acid (GABA), one of the neurotransmitters at terminals of cochlear efferent fibres A significant increase of the latencies was observed after noise alone. In subjects taking alprazolam when they are exposed to noise, the effect of noise on the ABR latencies is reduced, but not abolished. The effects of alprazolam on the ABR are consis…

AdultMaleLinguistics and Languagemedicine.medical_specialtyAdolescentmedicine.drug_classAnxietyAudiologyLanguage and LinguisticsSpeech and HearingCochlear efferentReference ValuesPonsEvoked Potentials Auditory Brain StemReaction Timeotorhinolaryngologic diseasesHumansMedicineAuditory Fatiguegamma-Aminobutyric AcidMedullaMedulla OblongataBenzodiazepineAlprazolambusiness.industryPonsNoiseAnti-Anxiety AgentsAlprazolamAnxietyFemaleBrainstemmedicine.symptomNoisebusinessmedicine.drugInternational Journal of Audiology
researchProduct