Search results for "valve"

showing 10 items of 576 documents

Multimodality imaging approach to paradoxical embolism: a cauliflower mass on the Eustachian valve

2020

The Eustachian valve was first described by Bartolomeo Eustachio (Italian anatomist) at 1552. It is an embryological remnant of the inferior vena cava valve that prenatally directs the oxygenated blood from inferior vena cava across the patent foramen ovale (PFO) into systemic circulation. Generally, following birth, after the closure of the foramen ovale it gradually regresses and not have a specific function, but it may persist in some patients as a floating membrane in the right atrium (RA), a nonpathological functionless structure.1 The prevalence of Eustachian valve in the normal population is unknown. Generally, it is an incidental finding without any significant pathophysiological co…

medicine.medical_specialtyParadoxical embolismbusiness.industrymedicineGeneral MedicineRadiologyCardiology and Cardiovascular Medicinemedicine.diseasebusinessMultimodality imaging approach paradoxical embolism Eustachian valve.Eustachian Valve
researchProduct

From Clinical Imaging to Patient-Specific Computational Model: Rapid Adaptation of the Living Heart Human Model to a Case of Aortic Stenosis

2021

Aortic stenosis (AS) is the most common acquired heart valve disease in the developed world. Traditional methods of grading AS have relied on the measurement of aortic valve area and transvalvular pressure gradient. Recent research has highlighted the existence of AS variants that do not meet classic criteria for severe AS such as low-flow, low-gradient AS. With the development of sophisticated multi-scale computational models, investigation into the left ventricular (LV) biomechanics of AS offers new insights into the pathophysiology that may guide treatment decisions surrounding AS. Building upon our prior study entailing LV-aortic coupling where AS conditions were applied to the idealize…

medicine.medical_specialtyPatient-specific modelingEjection fractionCardiac computed tomographybusiness.industrymedicine.medical_treatmentAortic stenosismedicine.diseaseStenosismedicine.anatomical_structureBlood pressureInternal medicinemedicine.arteryCirculatory systemAscending aortamedicineCardiologyHeart valvebusinessPressure gradientCardiac catheterization
researchProduct

Predictive Factors, Management, and Clinical Outcomes of Coronary Obstruction Following Transcatheter Aortic Valve Implantation

2013

Objectives This study sought to evaluate the main baseline and procedural characteristics, management, and clinical outcomes of patients from a large cohort of patients undergoing transcatheter aortic valve implantation (TAVI) who suffered coronary obstruction (CO). Background Very little data exist on CO following TAVI. Methods This multicenter registry included 44 patients who suffered symptomatic CO following TAVI of 6,688 patients (0.66%). Pre-TAVI computed tomography data was available in 28 CO patients and in a control group of 345 patients (comparisons were performed including all patients and a cohort matched 1:1 by age, sex, previous coronary artery bypass graft, transcatheter valv…

medicine.medical_specialtyPercutaneous aortic valve replacementbusiness.industrymedicine.medical_treatmentPercutaneous coronary interventionSurgeryLeft coronary arteryCoronary occlusionRight coronary arterymedicine.arteryInternal medicineCohortmedicineCardiologyCardiology and Cardiovascular MedicinebusinessComplicationTIMIJournal of the American College of Cardiology
researchProduct

Cardiac computed tomography assessment of the near term impact of percutaneous ventricular restoration therapy (parachute®) on mitral valve geometry

2015

Objectives The aim of current study is to assess the near term impact of percutaneous ventricular restoration therapy (PVR), Parachute® on mitral valve (MV) geometry by cardiac computed tomography (CCT). Background Recent data demonstrates the feasibility of PVR for treatment of post anterior myocardial infarction (MI) heart failure. Little is known, however, about the interaction of the device and left ventricular structures, particularly the MV apparatus. Methods This is a retrospective Core Laboratory analysis of Parachute Trials’ CCT data. Patients with paired (before and after Parachute implant) CCT acquisitions were included into analysis. MV geometric parameters were measured. Result…

medicine.medical_specialtyPercutaneousCardiac computed tomographybusiness.industryDiastoleAnterior myocardial infarctionGeometryGeneral Medicine030204 cardiovascular system & hematologymedicine.disease03 medical and health sciences0302 clinical medicinemedicine.anatomical_structureHeart failureMitral valveInternal medicinemedicineCardiologyRadiology Nuclear Medicine and imaging030212 general & internal medicineImplantCore laboratoryCardiology and Cardiovascular MedicinebusinessCatheterization and Cardiovascular Interventions
researchProduct

Patient selection, echocardiographic screening and treatment strategies for interventional tricuspid repair using the edge-to-edge repair technique

2018

Severe tricuspid regurgitation (TR) has long been neglected despite its well-known association with mortality. While surgical mortality rates remain high in isolated tricuspid valve surgery, interventional TR repair is rapidly evolving as an alternative to cardiac surgery in selected patients at high surgical risk. Currently, interventional edge-to-edge repair is the most frequently applied technique for TR repair even though a device has not been developed for this particular indication. Due to the inherent differences in tricuspid and mitral valve anatomy and pathology, percutaneous repair of the tricuspid valve is challenging due to a variety of factors including the complexity and varia…

medicine.medical_specialtyPercutaneousProcedural approach610 Medicine & healthRegurgitation (circulation)030204 cardiovascular system & hematology2705 Cardiology and Cardiovascular Medicine03 medical and health sciences0302 clinical medicineMitral valveHumansMedicinecardiovascular diseases030212 general & internal medicineTRICUSPID VALVE REPAIRHeart Valve Prosthesis ImplantationTricuspid valvebusiness.industryPatient SelectionMitral Valve InsufficiencyTricuspid Valve InsufficiencyCardiac surgery10020 Clinic for Cardiac SurgeryTreatment Outcomemedicine.anatomical_structureEchocardiographycardiovascular systemTreatment strategyTricuspid ValveRadiologyCardiology and Cardiovascular Medicinebusiness
researchProduct

Fully Percutaneous Transaxillary Aortic Valve Replacement With Effective Bailout Plan for Vascular Complications.

2020

medicine.medical_specialtyPercutaneousbusiness.industryAortic Valve StenosisTAVRsubclavian approachtransaxillary TAVRmedicine.diseaseSurgeryTAVITranscatheter Aortic Valve ReplacementPostoperative ComplicationsTreatment Outcometransaxillary TAVIAortic valve replacementRisk FactorsAortic ValveHeart Valve ProsthesismedicineHumansCardiology and Cardiovascular MedicinebusinessBailoutJACC. Cardiovascular interventions
researchProduct

Percutaneous puncture of an aorto‐bifemoral bypass graft and successful closure with MANTA ® device in transfemoral TAVR

2021

Transfemoral aortic valve replacement (TAVR) has become a standard therapeutic option for patients with symptomatic severe aortic stenosis. Special anatomies can pose distinct challenges for vascular access and later closure of the access site, for example, in preoperated patients. Here, we elucidate a case of transfemoral TAVR with vascular access by direct puncture of an aorto-bifemoral bypass graft and illustrate the feasibility of vascular closure by an anchored collagen-plug vascular closure device (Teleflex MANTA® ).

medicine.medical_specialtyPercutaneousbusiness.industryVascular accessClosure (topology)030204 cardiovascular system & hematologymedicine.diseaseSurgery03 medical and health sciencesStenosis0302 clinical medicineAortic valve replacementDirect punctureAccess sitemedicineRadiology Nuclear Medicine and imagingVascular closure device030212 general & internal medicineCardiology and Cardiovascular MedicinebusinessEchocardiography
researchProduct

Quantitative and Qualitative Platelet Derangements in Cardiac Surgery and Extracorporeal Life Support

2021

Thrombocytopenia and impaired platelet function are known as intrinsic drawbacks of cardiac surgery and extracorporeal life supports (ECLS). A number of different factors influence platelet count and function including the inflammatory response to a cardiopulmonary bypass (CPB) or to ECLS, hemodilution, hypothermia, mechanical damage and preoperative treatment with platelet-inhibiting agents. Moreover, although underestimated, heparin-induced thrombocytopenia is still a hiccup in the perioperative management of cardiac surgical and, above all, ECLS patients. Moreover, recent investigations have highlighted how platelet disorders also affect patients undergoing biological prosthesis implanta…

medicine.medical_specialtyPlatelet disorderbiological prosthesisRESPIRATORY-FAILUREProsthesis Implantationlcsh:MedicinethrombocytopeniaReview030204 cardiovascular system & hematologyextracorporeal life supportExtracorporeallaw.invention03 medical and health sciences0302 clinical medicinelawInternal medicineCardiopulmonary bypassmedicinePlatelet030304 developmental biologyplateletUNFRACTIONATED HEPARIN0303 health sciencesCARDIOPULMONARY BYPASSbusiness.industrylcsh:RMEMBRANE-OXYGENATIONACTIVATED PLATELETSGeneral MedicineHypothermiaENDOTHELIAL-CELLSANTIBODY-FORMATIONCardiac surgeryinflammationCORONARY-ARTERY-BYPASSLife supportAORTIC-VALVE-REPLACEMENTCardiologyHEPARIN-INDUCED THROMBOCYTOPENIAmedicine.symptombusinesscardiac surgeryJournal of Clinical Medicine
researchProduct

CAD Modeling for Evaluating LVOT Obstruction in Transcatheter Mitral Valve Replacement

2019

The current generation of transcatheter heart valves (THV), as the Edwards SAPIEN 3 Ultra (S3), is not specifically designed for mitral position implantation and has intrinsic design geometry that may make mitral implantation suboptimal. This study aimed to develop a computed-tomography (CT) based CAD workflow for the preoperative planning of transcatheter mitral valve replacement (TMVR) by evaluating the resulting obstruction in the left ventricular outflow tract (LVOT). Specifically, the computational framework to reconstruct heart anatomy and virtually deploy the THV into mitral valve annulus was developed and successively applied to the cases of two patients who experienced annuloplasty…

medicine.medical_specialtyPreoperative planningbusiness.industryHeart anatomymedicine.medical_treatmentMitral valve replacementCAD030204 cardiovascular system & hematologyVirtual simulation03 medical and health sciences0302 clinical medicineInternal medicineMedical imagingmedicineCardiologyVentricular outflow tractMitral Valve AnnulusCADcardiovascular diseases030212 general & internal medicineMedical imagingbusinessReverse engineeringTranscatheter mitral valve replacementEdwards sapien
researchProduct

Septic cardiomyopathy: evidence for a reduced force-generating capacity of human atrial myocardium in acute infective endocarditis

2017

AbstractBackground:This study analyzes the myocardial force-generating capacity in infective endocarditis (IE) using an experimental model of isolated human atrial myocardium. In vivo, it is difficult to decide whether or not alterations in myocardial contractile behavior are due to secondary effects associated with infection such as an altered heart rate, alterations of preload and afterload resulting from valvular defects, and altered humoral processes. Our in vitro model using isolated human myocardium, in contrast, guarantees exactly defined experimental conditions with respect to preload, afterload, and contraction frequency, thus not only preventing confounding by in vivo determinants…

medicine.medical_specialtyRD1-811medicine.medical_treatmentHemodynamicsmyocardial contractilityIsometric exercise030204 cardiovascular system & hematologyContractility03 medical and health sciences0302 clinical medicineAfterloadInternal medicinemedicineEndocarditiscardiovascular diseasesacute infective endocarditisbusiness.industryMitral valve replacement030208 emergency & critical care medicineOriginal Articlesmedicine.diseasePreloadInfective endocarditisseptic cardiomyopathyCardiologycardiovascular systemSurgerybusinesshuman atrial myocardiumInnovative Surgical Science
researchProduct