Search results for "ventilation"
showing 10 items of 476 documents
Differential contribution of dead space ventilation and low arterial pCO2 to exercise hyperpnea in patients with chronic heart failure secondary to i…
2003
In chronic heart failure (CHF), the abnormally large ventilatory response to exercise (VE/VCO(2) slope) has 2 conceptual elements: the requirement of restraining arterial partial pressure of carbon dioxide (pCO(2)) from increasing (because of an increased ratio between increased physiologic dead space and tidal volume [VD/VT]) and the depression of arterial pCO(2) by further increased ventilation, which necessarily implies an important non-carbon dioxide stimulus to ventilation. We aimed to assess the contribution of these 2 factors in determining the elevated VE/VCO(2) slope in CHF. Thirty patients with CHF underwent cardiopulmonary exercise testing (age 65 +/- 11 years, left ventricular e…
Regional Cerebral Blood Flow in Cases of Brain Tumor
1969
The present series consists of 21 patients with brain tumors: 12 malignant gliomas, 4 oligo- dendro gliomas, 3 meningeomas and 2 metastases, studied by the133Xe-gamma-clearance rCBF method. In 16 patients at least 3 determinations of rCBF were performed: a) in the resting state, R; b) during hyperventilation, HV, and c) during hypertension, HT. Of the remaining 5 patients, 1 was studied only during R, while the other 4 were submitted either to HV or to HT additionally to the R study. The average age of this series of patients was 47 years, the youngest being 19 and the oldest 64. rCBF studies had to be performed under general anesthesia (N2O + O2, Engstrom respirator) in 5 instances in whic…
Effect of Hyper- and Hypoventilation on CBF during Anesthesia
1969
Alexander and Wollman [1, 2, 4, 8], Harper [5] and McDowall and other investigators have published observations on CBF during anaesthesia in man and dog, when arterial pCO2 was altered by hyper- or hypoventilation.
On interactive multiobjective optimization with NIMBUS® in chemical process design
2005
We study multiobjective optimization problems arising from chemical process simulation. The interactive multiobjective optimization method NIMBUS®, developed at the University of Jyvaskyla, is combined with the BALAS® process simulator, developed at the VTT Technical Research Center of Finland, in order to provide a new interactive tool for designing chemical processes. Continuous interaction between the method and the designer provides a new efficient approach to explore Pareto optimal solutions and helps the designer to learn about the behaviour of the process. As an example of how the new tool can be used, we report the results of applying it in a heat recovery system design problem rela…
Assessment of a single-acquisition imaging sequence for oxygen-sensitive (3)He-MRI.
2001
MRI of the lungs using hyperpolarized helium-3 (3He) allows the determination of intrapulmonary oxygen partial pressures (pO2). The need to separate competing processes of signal loss has hitherto required two different imaging series during two different breathing maneuvers. In this work, a new imaging strategy to measure pO2 by a single series of consecutive scans is presented. The feasibility of the method is demonstrated in three healthy human volunteers. Maps and histograms of intrapulmonary pO2 are calculated. Changes in the oxygen concentration of the inhaled gas mixture are well reproduced in the histograms. Monte Carlo (MC) simulations of the temporal evolution of 3He hyperpolariza…
Energy performance evaluation of a demo solar desiccant cooling system with heat recovery for the regeneration of the adsorption material
2012
Abstract Since July 2008, a Solar Desiccant Evaporative Cooling (DEC) system has been operating as a test plant at the solar laboratory of the Dipartimento di Energia (ex DREAM) of the University of Palermo. The system is composed of an air handling unit (AHU) designed for ventilation of the laboratory coupled with a radiant ceiling that provides most of the required sensible cooling/heating energy. Flat plate collectors deliver part of the regeneration heat of the desiccant wheel during the summertime and are used for space heating during the wintertime. The system was designed for high humidity loads because of the typical climate conditions at the site and the need to support a radiant c…
High-flow nasal therapy versus noninvasive ventilation in COPD patients with mild-to-moderate hypercapnic acute respiratory failure: study protocol f…
2019
Background Noninvasive ventilation (NIV) is indicated to treat respiratory acidosis due to exacerbation of chronic obstructive pulmonary disease (COPD). Recent nonrandomized studies also demonstrated some physiological effects of high-flow nasal therapy (HFNT) in COPD patients. We designed a prospective, unblinded, multicenter, randomized controlled trial to assess the noninferiority of HFNT compared to NIV with respect to the reduction of arterial partial pressure of carbon dioxide (PaCO2) in patients with hypercapnic acute respiratory failure with mild-to-moderate respiratory acidosis. Methods We will enroll adult patients with acute hypercapnic respiratory failure, as defined by arterial…
Pulmonologists, Mechanical Ventilation and Complementary Techniques
2014
MODELIZACIÓN MEDIANTE CFD DE PARA EVALUAR LA VENTILACIÓN EN UN EDIFICIO ARQUEOLÓGICO, DATOS PRELIMINARES.
2016
[EN] The present study addresses the influences of wind flow structure, as an important factor responsible of material damage (erosion contributing) on “Casa di Diana” Mithraeum, a roman building (130 A.D.) sited on Ostia Antica (archaeological site, Rome – Italy), through the Computational Fluid Dynamics (CFD) simulations and direct measurements for its verification and validation (V&V). In this preliminary work, we present results relating to 3D reconstruction (geometry of the entire building) and the mesh importing on Fluent software. In general, the data check confirms, with ±10%, a good agreement (model) between the numerical solutions and direct measurements data by portable sensor. F…
Cardiopulmonary Exercise Testing in Patients with Chronic Heart Failure: Prognostic Comparison from Peak VO2 and VE/VCO2 Slope
2010
Background: Cardiopulmonary exercise testing with ventilatory expired gas analysis (CPET) has proven to be a valuable tool for assessing patients with chronic heart failure (CHF). The maximal oxygen uptake (peak V02) is used in risk stratification of patients with CHF. The minute ventilation-carbon dioxide production relationship (VE/VCO2 slope) has recently demonstrated prognostic significance in patients with CHF. Methods: Between January 2006 and December 2007 we performed CPET in 184 pts (146 M, 38 F, mean age 59.8 ± 12.9 years), with stable CHF (96 coronary artery disease, 88 dilated cardiomyopathy), in NYHA functional class II (n.107) - III (n.77), with left ventricular ejection frac…