Search results for "vision."
showing 10 items of 4900 documents
Tracing patterns of activity in the human skeleton: an overview of methods, problems, and limits of interpretation.
2009
Studies of patterns of activity in human skeletal remains have grown in number over the last few years. Different methods have been used to reconstruct activity patterns in past populations. In this review of the available literature the common themes of these studies have been isolated in order to show that many studies do not truly conform to the standards of the field. Inadequate sample size, too far-reaching conclusions and neglect of other possible explanations are among the problems easily recognised in the literature. Many assumptions are lacking a sound experimental basis, and it becomes increasingly evident that there are many more problems and limits of interpretations than have b…
Methodological Aspects of the Application of the Naka-Rushton Equation to Clinical Electroretinogram
1993
The nonlinear relation between stimulus intensity and response amplitude of the electroretinogram (ERG) scotopic b wave can be described by a curve based on the Naka-Rushton (NR) equation. Up to now, the NR equation has been used to assess the features of the normal and pathological ERG, but the best approach for a correct evaluation of the parameters is still debatable. The parameters are thought to be related to the different conditions of retinal activities. The method is well known in experimental laboratories but is quite unusual at the clinical level. In the present paper the derivative analysis of the NR function is proposed as an easier approach to understand the variations of the N…
Evaluation of Physiological Parameters on Discomfort Glare Thresholds Using LUMIZ 100 Tool
2021
Purpose To assess the links between discomfort glare sensitivity and physiological factors such as eye biometry, refraction, skin phototype, age, and gender among a large sample of healthy human subjects. Methods A total of 489 participants who were 20 to 70 years old (241 men, 248 women) underwent discomfort glare threshold measurements via the LUMIZ 100. Eye biometry and optical quality were measured using a Zeiss IOLMaster 700 biometer and i.Profiler aberrometer. Iris color, skin tone, age, gender, eyeglasses use, chronotype, fatigue level, self-evaluation of light sensitivity, and time spent outdoors were determined. Statistical analysis was carried out using nonparametric Mann–Whitney …
Asymmetric modulation of human visual cortex activity during 10 degrees lateral gaze (fMRI study).
2005
We used BOLD fMRI to study the differential effects of the direction of gaze on the visual and the ocular motor systems. Fixation of a target straight ahead was compared to fixation of a target 10 degrees to the right and 10 degrees to the left from gaze straight ahead, and to eyes open in complete darkness in thirteen healthy volunteers. While retinotopic coordinates remained the same in all fixation conditions, the fixation target shifted with respect to a head-centered frame of reference. During lateral fixation, deactivations in higher-order visual areas (one ventral cluster in the lingual and fusiform gyri and one dorsal cluster in the postero-superior cuneus) and, as a trend, activati…
Visual Performance of Four Simultaneous-Image Multifocal Contact Lenses Under Dim and Glare Conditions
2014
To assess and compare the effects of four simultaneous-image multifocal contact lenses (SIMCLs), and those with distant-vision-only contact lenses on visual performance in early presbyopes, under dim conditions, including the effects of induced glare.In this double-masked crossover study design, 28 presbyopic subjects aged 40 to 46 years were included. All participants were fitted with the four different SIMCLs (Air Optix Aqua Multifocal [AOAM; Alcon], PureVision Multifocal [PM; BauschLomb], Acuvue Oasys for Presbyopia [AOP; JohnsonJohnson Vision], and Biofinity Multifocal [BM; CooperVision]) and with monofocal contact lenses (Air Optix Aqua, Alcon). After 1 month of daily contact lens wear…
fMRI signal increases and decreases in cortical areas during small-field optokinetic stimulation and central fixation
2001
Small-field optokinetic nystagmus (OKN) was performed in seven healthy volunteers in order to analyze the activation and deactivation patterns of visual motion, ocular motor, and multisensory vestibular cortex areas by means of fMRI during coherent visual motion stimulation. BOLD signal decreases (deactivations) were found in the first and second long insular gyri and retroinsular areas (the human homologue of the parietoinsular vestibular cortex and the visual posterior sylvian area in the monkey) of both hemispheres, extending into the transverse temporal gyrus and inferior-anterior parts of the superior temporal gyrus (BA 22), and the precentral gyri at two separate sites (BA 4 and 6). F…
Blue-yellow deficiency in workers exposed to low concentrations of organic solvents
1997
Objectives: To evaluate the effects of low concentrations of organic solvents on color vision. Methods: Color vision was examined in 24 workers exposed to mixtures of solvents and in 24 control subjects. Exposure to mixtures was below the threshold-limit values. Color vision ability was assessed using the Ishihara plates (to screen for congenital dyschromatopsia), the Farnsworth panel D-15 test, the Lanthony desaturated panel D-15 test, and the Standard Pseudoisochromatic Plates part 2 (SPP2 test). Results: The comparatively less sensitive Farnsworth panel D-15 test failed to show any difference between the groups, but the Lanthony panel D-15 desaturated test as well as the SPP2 test showed…
Characterization of Small Incidental Indeterminate Hypoattenuating Hepatic Lesions: Added Value of Single-Phase Contrast-Enhanced Dual-Energy CT Mate…
2018
OBJECTIVE. The objective of this study is to determine whether single-phase contrast-enhanced dual-energy CT (DECT) material attenuation analysis improves the characterization of small (< 2.0 cm) incidental indeterminate hypoattenuating hepatic lesions, compared with conventional single-energy CT evaluation. MATERIALS AND METHODS. This retrospective study involved 55 patients (24 men and 31 women; mean [± SD] age, 63.9 ± 15.3 years) with 77 incidental hypoattenuating hepatic lesions (59 benign and 18 malignant lesions) measuring 0.5–2.0 cm who underwent single-phase contrast-enhanced DECT of the abdomen for pain. For each lesion, attenuation measurements were obtained using blended 120-k…
Does viotin activate violin more than viocin? On the use of visual cues during visual-word recognition.
2013
The vast majority of neural and computational models of visual-word recognition assume that lexical access is achieved via the activation of abstract letter identities. Thus, a word’s overall shape should play no role in this process. In the present lexical decision experiment, we compared word-like pseudowords like viotín (same shape as its base word: violín) vs. viocín (different shape) in mature (college-aged skilled readers), immature (normally reading children), and immature/impaired (young readers with developmental dyslexia) word-recognition systems. Results revealed similar response times (and error rates) to consistent-shape and inconsistent-shape pseudowords for both adult skille…
Preattentive and attentive responses to changes in small numerosities of tones in adult humans
2016
The brain hosts a primitive number sense to non-symbolically represent numerosities of objects or events. Small exact numerosities (~4 or less) can be individuated in parallel. In contrast, large numerosities (more than ~4) can only be approximated. However, whether small numerosities can be approximated without their parallel individuation remains unclear. Parallel individuation is suggested to be an attentive process and numerical approximation an automatic process. We, therefore, tested whether small numerosities can be represented preattentively. We recorded adult humans׳ event-related potentials (ERPs) and behavioral responses to 300-ms sequences of six tones (each of either 440 Hz or …