Search results for "visual acuity."

showing 10 items of 455 documents

Assessment of environmental AMD risk factors in a population of patients suffering from stroke and myocardial infarction

2010

International audience; Purpose: Stroke and myocardial infarction are common diseases occurring in patients suffering from Age Macular Degeneration (AMD). We assessed the rate of AMD and AMD risk factors in patients suffering from recent stroke or myocardial infarction. Methods: Patients suffering from a recent stroke or myocardial infarction (less than 1 month) benefited from a thorough ophthalmic examination with the following measurements and evaluations: visual acuity, intraocular pressure, fundus photography, Raman spectroscopy and macular OCT. In the same time a food questionnaire was dispensed. Finally, blood samples to measure fatty acids and lutein were performed. Results: 74 patie…

medicine.medical_specialtyIntraocular pressureLongitudinal studyVisual acuitygenetic structuresPopulation03 medical and health sciences0302 clinical medicineInternal medicinemedicineMyocardial infarction[SDV.MHEP.OS]Life Sciences [q-bio]/Human health and pathology/Sensory OrganseducationStrokeeducation.field_of_study[SDV.MHEP] Life Sciences [q-bio]/Human health and pathologymedicine.diagnostic_testbusiness.industryFundus photographyGeneral MedicineMacular degenerationmedicine.diseaseeye diseases3. Good healthSurgeryOphthalmology[SDV.AEN] Life Sciences [q-bio]/Food and Nutrition[SDV.MHEP.OS] Life Sciences [q-bio]/Human health and pathology/Sensory Organs030221 ophthalmology & optometrysense organsmedicine.symptombusiness[SDV.AEN]Life Sciences [q-bio]/Food and Nutrition030217 neurology & neurosurgery[SDV.MHEP]Life Sciences [q-bio]/Human health and pathology
researchProduct

Long-term Results of Combined Cataract, IOL and Glaucoma Surgery

1994

OBJECTIVE: To determine the long-term intraocular pressure (IOP) control in patients that had undergone combined extracapsular cataract extraction (ECCE), lens implant and glaucoma surgery and compare the results obtained by the longer and shorter follow-up groups. STUDY DESIGN: Retrospective study of postoperative results with a minimum follow-up of one year, maximum of 10 years and a mean of 33.1 months. SETTING: Department of Opthalmology, ‘La Fe’ University Hospital. Department of Surgery of Valencia School of Medicine, Valencia, Spain. PATIENTS: Ninety-five eyes examined of 72 patients presenting coexisting cataract and glaucoma who underwent combined surgery in the last 11 years. MAIN…

medicine.medical_specialtyIntraocular pressureVisual acuitygenetic structuresbusiness.industrymedicine.medical_treatmentGlaucomaRetrospective cohort studyLong term resultsmedicine.diseaseeye diseasesSurgeryOphthalmologyOphthalmologyGlaucoma surgeryPostoperative resultsMedicineTrabeculectomysense organsmedicine.symptombusinessEuropean journal of Implant and Refractive Surgery
researchProduct

2015

Purpose This paper describes the study design, methodology, cohort profile and self-reported diseases in the ophthalmological branch of the Gutenberg Health Study (GHS). Methods The GHS is an ongoing, prospective, interdisciplinary, single-center, population-based cohort study in Germany. The main goals of the ophthalmological section are to assess the prevalence and incidence of ocular diseases and to explore risk factors, genetic determinants and associations with systemic diseases and conditions. The eye examination at baseline included a medical history, self-reported eye diseases, visual acuity, refractive errors, intraocular pressure, visual field, pachymetry, keratometry, fundus phot…

medicine.medical_specialtyIntraocular pressureeducation.field_of_studyMultidisciplinaryVisual acuitygenetic structuresmedicine.diagnostic_testbusiness.industryPopulationFundus photographyGlaucomamedicine.diseaseeye diseasesEye examinationOphthalmologyCohortmedicineOptometrymedicine.symptomeducationbusinessCohort studyPLOS ONE
researchProduct

Implantation of a custom intraocular lens with a 30-diopter torus for the correction of high astigmatism after penetrating keratoplasty.

2003

Abstract We present a 62-year-old woman who had implantation of an intraocular lens (IOL) with a torus of 30.0 diopters (D) in an eye after penetrating keratoplasty. The patient presented with cataract and a best corrected visual acuity of 20/400. Penetrating keratoplasty was performed in 1975 because of decompensated keratoconus. With a clear but inferiorly decentered corneal graft, visual acuity was limited because of keratoplasty-related high corneal astigmatism of 22.5@156 that could not be successfully treated with spectacles or contact lenses. A custom toric IOL with –30.0 D of cylindrical power was implanted in the capsular bag via a sclerocorneal tunnel incision. Additionally, a sph…

medicine.medical_specialtyKeratoconusRefractive errorVisual acuitygenetic structuresmedicine.medical_treatmentEye diseaseVisual AcuityIntraocular lensAstigmatismKeratoconusProsthesis DesignCataractHigh astigmatismLens Implantation IntraocularOphthalmologymedicineHumansDioptreLenses IntraocularPhacoemulsificationbusiness.industryAstigmatismCorneal TopographyMiddle Agedmedicine.diseaseeye diseasesSensory SystemsOphthalmologyOptometrySurgeryFemalesense organsmedicine.symptombusinessKeratoplasty PenetratingJournal of cataract and refractive surgery
researchProduct

Bilateral Ultrathin Descemet’s Stripping Automated Endothelial Keratoplasty vs. Bilateral Penetrating Keratoplasty in Fuchs’ Dystrophy: Corneal Highe…

2021

Background and Objectives: The objective of this paper is to compare the visual outcomes and quality of life (QoL) after bilateral ultrathin Descemet’s stripping automated endothelial keratoplasty (UT-DSAEK) with bilateral penetrating keratoplasty (PK) for Fuchs’ endothelial dystrophy (FED). Materials and Methods: Retrospective comparative cohort study, including 11 patients with FED who underwent bilateral PK and 13 patients with FED who underwent bilateral UT-DSAEK. All patients were already pseudophakic or had undergone a combined cataract procedure. The main outcomes were corrected distance visual acuity (CDVA) corneal higher-order aberrations (HOAs), contrast sensitivity (CS) and quali…

medicine.medical_specialtyMedicine (General)Visual acuityDistance visual acuitygenetic structuresvisual acuitymedia_common.quotation_subjectmedicine.medical_treatmentFuchs' dystrophyArticleCohort StudiesR5-920Quality of lifeOphthalmologyhigher-order aberrationmedicineContrast (vision)HumansEye surgerymedia_commonRetrospective Studiescontrast sensitivityhigher-order aberrationsbusiness.industryFuchs' Endothelial DystrophyDystrophybilateral penetrating keratoplastyGeneral Medicinemedicine.diseasebilateral ultrathin DSAEKeye diseasesAberrations of the eyebilateral ultrathin DSAEK; bilateral penetrating keratoplasty; visual acuity; contrast sensitivity; higher-order aberrations; quality of lifequality of lifevisual acuity.medicine.symptombusinessDescemet Stripping Endothelial KeratoplastyKeratoplasty PenetratingMedicina
researchProduct

<p>Visual And Refractive Outcomes In Hyperopic Pseudophakic Patients Implanted With A Trifocal Intraocular Lens</p>

2019

Purpose To assess visual and refractive results after bilateral implantation of a trifocal intraocular lens (IOL) in patients with hyperopia. Methods In a retrospective nonrandomized study, 196 eyes of 98 patients had bilateral implantation of a trifocal IOL. The Barrett Universal II formula was used for IOL power calculation. Eyes were divided into two groups for their analysis: low-moderate, with IOL power ranging from 22 to 26 D, and high, with IOL power ranging from 25 to 34 D. Refractive error was used to assess predictability, and corrected distance visual acuity (CDVA) and uncorrected distance visual acuity values were used to assess efficacy and safety of the surgery. Results Six mo…

medicine.medical_specialtyRefractive errorDistance visual acuityVisual acuitygenetic structuresbusiness.industrymedicine.medical_treatmentSpherical equivalentIntraocular lensPhacoemulsificationmedicine.diseaseeye diseases03 medical and health sciencesOphthalmology0302 clinical medicineOphthalmology030221 ophthalmology & optometrymedicineIn patientsense organsmedicine.symptombusiness030217 neurology & neurosurgeryClinical Ophthalmology
researchProduct

Toric phakic intraocular lens

2003

Abstract Objective To evaluate safety, efficacy, predictability, stability, complications, and patient satisfaction after implantation of Artisan toric phakic intraocular lenses (TPIOLs) for the correction of myopia or hyperopia with astigmatism. Design Prospective, nonrandomized, comparative (self-controlled) multicenter trial. Participants Seventy eyes of 53 patients (mean, 35 years; range, 22–59 years) with preoperative spherical equivalent between +6.50 and −21.25 diopters (D) and cylinder between 1.50 and 7.25 D. Methods Seventy eyes underwent implantation of a TPIOL with an optical zone of 5.0 mm (Artisan, Ophtec, Groningen, The Netherlands). The dioptric power of the intraocular lens…

medicine.medical_specialtyRefractive errorVisual acuitygenetic structuresKeratometerbusiness.industrymedicine.medical_treatmentIntraocular lensAstigmatismmedicine.diseasePhakic intraocular lenseye diseaseslaw.inventionToric lensOphthalmologylawOphthalmologymedicinesense organsmedicine.symptombusinessDioptreOphthalmology
researchProduct

Changes in higher-order aberrations after implantation of a foldable iris-claw lens in myopic phakic eyes

2006

Purpose To evaluate the change in higher-order aberrations (HOAs) after implantation of a foldable iris-claw phakic intraocular lens (pIOL) in myopic eyes. Setting Department of Ophthalmology, Johannes Gutenberg-University, Mainz, Germany. Methods This prospective nonrandomized comparative self-controlled trial included 41 eyes that had implantation of a foldable iris-claw pIOL between July 2003 and November 2004. All patient data for HOAs (Zernike coefficient) were measured and calculated using the same pupil size preoperatively and postoperatively, and the root-mean-square (RMS) wavefront error was calculated. Examinations were performed preoperatively as well as 1 week and 3, 6, and 12 m…

medicine.medical_specialtyRefractive errorgenetic structuresAnterior ChamberEye diseaseVisual AcuityIrisPhakic intraocular lensCorneaVision disorderLens Implantation IntraocularOphthalmologyLens CrystallineMyopiaHumansMedicineProspective StudiesIris clawDioptreLenses Intraocularbusiness.industryRefractive Errorsmedicine.diseaseeye diseasesSensory SystemsOphthalmologyAberrations of the eyemedicine.anatomical_structureLens (anatomy)Silicone ElastomersSurgerysense organsmedicine.symptombusinessJournal of Cataract and Refractive Surgery
researchProduct

Arteriovenöse Dissektion (AVD) bei retinalen Venolenastverschlüssen

2009

BACKGROUND: The aim of this study is to report on arteriovenous sheathotomy in branch retinal vein occlusion (BRVO) with a long-term follow-up and examine the visual field effects of this surgical approach. PATIENTS AND METHODS: In a clinical trial 36 eyes with branch retinal vein occlusion (22 eyes with ischaemia, 14 eyes with chronic macular oedema) underwent surgical decompression accompanied by peeling of the membrana limitans interna after prior isovolemic haemodilution for 3 months had been unsuccessfull. RESULTS: All eyes showed a significant reduction of macular oedema 3 months after surgery. During follow-up (median: 26.4 months) visual acuity increased in 24 / 36 eyes and was stab…

medicine.medical_specialtyRetinaVisual acuitygenetic structuresDecompressionbusiness.industrymedicine.diseaseeye diseasesSurgeryVisual fieldOphthalmologymedicine.anatomical_structuremedicineBranch retinal vein occlusionsense organsmedicine.symptombusinessVitreous baseRetinal holeOptic discKlinische Monatsblätter für Augenheilkunde
researchProduct

Adult Coats’ Disease Successfully Managed with the Dexamethasone Intravitreal Implant (Ozurdex®) Combined with Retinal Photocoagulation

2012

Purpose: To report a case of Coats’ disease managed with the dexamethasone intravitreal implant Ozurdex® (Allergan, Inc., Irvine, Calif., USA) combined with retinal photocoagulation. Methods: A 46-year-old female with 20/200 visual acuity was diagnosed with Coats’ disease with secondary retinal vasoproliferative tumor. An initial approach was performed with an intravitreal injection of the sustained-release dexamethasone implant Ozurdex. After reattachment of the retina, the telangiectatic vessels were treated with laser photocoagulation. Results: The patient’s visual acuity improved to 20/25 after the intravitreal Ozurdex. No further recurrences of exudation were evident through the 12-mon…

medicine.medical_specialtyRetinal vasoproliferative tumorVisual acuitychemistry.chemical_compoundRetinal telangiectasislcsh:OphthalmologyOphthalmologymedicineDexamethasone Intravitreal ImplantDexamethasone intravitreal implant (Ozurdex®)Coats' diseaseCoats’ diseaseDexamethasoneRetinabusiness.industryRetinalmedicine.diseaseSurgeryOphthalmologymedicine.anatomical_structurechemistrylcsh:RE1-994Published: March 2012Retinal TelangiectasisImplantmedicine.symptombusinessmedicine.drugCase Reports in Ophthalmology
researchProduct