Search results for "visual acuity"
showing 10 items of 456 documents
Light scattering in artificial fog and simulated with light scattering filter.
2009
Disability glare, affecting e.g. road safety at night, may result either from intraocular light scattering or from external conditions such as fog. Measurements were made of light scattering in fog and compared with intraocular straylight data for normal eyes and eyes with simulated cataract. All measurements were made with a direct compensation flicker method. To estimate light scattering levels in fog, straylight measurements were carried in a fog chamber for different densities of fog. Density was characterized by the meteorological term visibility V and ranged from 7 to 25. Test distance for measurements in the fog was constant at 5 m. Cataract eye conditions were simulated by placing a…
Optical and Visual Quality of the Visian Implantable Collamer Lens Using an Adaptive-Optics Visual Simulator
2013
To evaluate visual and optical quality of the implantable collamer lens for different powers and sizes of incision surgery.Prospective study in humans.An adaptive optics visual simulator was used to measure 3 powers of implantable collamer lenses and simulate the implantable collamer lens wavefront aberration's pattern for small- and large-incision surgery. Visual acuity (VA) and contrast sensitivity were measured in 11 observers for 3- and 5-mm pupils. Modulation transfer function, point spread function, and Strehl ratio were calculated.At 3 mm pupil, no statistically significant differences were found between both incision sizes for any implantable collamer lens power, except for -15 diop…
The effect of spherical aberration on visual performance and refractive state for stimuli and tasks typical of night viewing
2018
Purpose: The aim of this work was to examine the impact of Seidel spherical aberration (SA) on optimum refractive state for detecting and discriminating small bright lights on a dark background. Methods: An adaptive-optics system was used to correct ocular aberrations of cyclopleged eyes and then systematically introduce five levels of Seidel SA for a 7-mm diameter pupil: 0, ± 0.18, and ± 0.36 diopters (D) mm−2. For each level of SA, subjects were required to detect one or resolve two points of light (0.54 arc min diameter) on a dark background. Refractive error was measured by adjusting stimulus vergence to minimize detection and resolution thresholds. Two other novel focusing tasks for si…
Multilayer amniotic membrane transplantation in severe ocular graft versus host disease
2001
To clarify the usefulness of multilayer amniotic membrane transplantation in an unusual case of calcareous corneal degeneration in a patient with graft-versus-host disease.A 20-year-old Caucasian woman had bilateral calcareous corneal degeneration of one year of evolution, secondary to graft-versus-host disease. Treatment for both eyes with topical steroids and antibiotic ointment was not successful. Right eye had a spontaneous corneal perforation, and a three-layer circle amniotic membrane graft was applied to the whole cornea.During a follow-up period of 20 months we observed stability of the corneal epithelium and stroma. The amniotic membrane-covered area showed rapid epithelization, re…
Influence of optic quality on contrast sensitivity and visual acuity in eyes with a rigid or flexible phakic intraocular lens
2009
Purpose To determine whether the difference in optic quality between 2 types of phakic intraocular lenses (pIOLs) affects visual quality. Setting Fundacion Oftalmologica del Mediterraneo, Valencia, Spain. Methods Before implantation of a pIOL for myopia, all eyes had an examination including corrected (CDVA) and uncorrected (UDVA) distance visual acuity testing, corneal endothelial cell count (ECC), and intraocular pressure (IOP) measurement. The postoperative outcomes, determined at least 1 year after surgery, were CDVA; UDVA; contrast sensitivity function under photopic, mesopic, and mesopic with glare conditions; ECC; IOP; keratometry (Scheimpflug photography); and total ocular aberratio…
Fixed Mydriatic Pupil Associated with an Intraocular Pressure Rise as a Complication of the Implant of a Phakic Refractive Lens (PRL)
2013
We describe a case report of a patient that was implanted with a posterior chamber phakic intraocular lens (Phakic Refractive Lens, PRL) for the correction of moderate myopia and who developed postoperatively a fixed mydriasis compatible with an Urrets-Zavalia Syndrome (UZS). Specifically, a sudden acute increase of IOP in the left eye was observed in the immediate postoperative period. After IOP stabilization, the refractive result was good, but a fixed and mydriatic pupil appeared. This condition led the patient to experience visual discomfort, halos, and glare associated with high levels of higher-order aberrations in spite of the good visual result. A tinted-contact lens was fitted in o…
Visual Acuity in Simple Myopic Astigmatism: Influence of Cylinder Axis
2006
Purpose. The relationship between astigmatic refractive errors and their associated visual acuity has been studied in recent years in the context of refractive power space. The influence of the axis of astigmatism remains a matter of controversy. Our goal in this study is to provide additional experimental evidence to clarify this subject. The influence of the simulated axis orientation was compared with other factors that affect visual acuity such as the particular design of the test and the differences between eyes. Methods. Simple myopic astigmatism from 0 to 3.00 D, in steps of 0.25 D, and with five different axes between 0° and 90°, were simulated on four healthy eyes of young observer…
Impact of the line of sight on toric phakic intraocular lenses for hyperopia
2003
We present a hyperopic patient with a decentered line of sight in whom the residual refractive error after toric phakic intraocular lens (TP IOL) implantation was improved by displacement and individualized treatment. A 35-year-old woman presented with asthenopic complaints 2 months after bilateral TP IOL implantation and IOL rotation 4 weeks later. Examination revealed the line of sight to be nasally and inferiorly decentered in relation to the center of the pupil. A more nasal reenclavation of the TP IOL decreased the coma, and the uncorrected visual acuity was 20/20. We conclude that line of sight should be measured before TP IOL implantation, especially in hyperopic eyes.
Temporal Structure of Human Gaze Dynamics Is Invariant During Free Viewing.
2015
We investigate the dynamic structure of human gaze and present an experimental study of the frequency components of the change in gaze position over time during free viewing of computer-generated fractal images. We show that changes in gaze position are scale-invariant in time with statistical properties that are characteristic of a random walk process. We quantify and track changes in the temporal structure using a well-defined scaling parameter called the Hurst exponent, H. We find H is robust regardless of the spatial complexity generated by the fractal images. In addition, we find the Hurst exponent is invariant across all participants, including those with distinct changes to higher or…
Avaliação da resposta de acomodação após tarefas visuais próximas usando diferentes dispositivos eletrônicos portáteis
2015
ABSTRACT Purpose: To assess the accommodation response after short reading periods using a tablet and a smartphone as well as determine potential differences in the accommodation response at various stimulus vergences using a Hartmann- Shack aberrometer. Methods: Eighteen healthy subjects with astigmatism of less than 1 D, corrected visual acuity of 20/20 or better, and normal findings in an ophthalmic examination were enrolled. Accommodation responses were obtained under three different conditions: accommodation system of the eye relaxed and visually stressed with a tablet and an smartphone for 10 min, at a distance of 0.25 m from the subject's eyes. Three measurements of accommodation res…