Search results for "wave"

showing 10 items of 6009 documents

Global-Local model for guided wave scattering problems with application to defect characterization in built-up composite structures

2020

Abstract Predicting scattering of elastic guided waves in multi-layered solid plates with geometrical and/or material discontinuities is of great interest to many fields, including ultrasonic-based Non-Destructive Testing (NDT) and health monitoring of critical structural components (SHM). The problem is complicated by the multimode and dispersive behaviour of the guided waves. This paper describes a unified Global-Local (GL) approach that is computationally efficient in cases that can be very complex in terms of geometry and/or material properties. One example of this is a composite built-up structure. The proposed GL procedure discretizes the “local” region with the scattering discontinui…

AcousticsNon-destructive testingClassification of discontinuitiesScatteringNondestructive testingGlobal-Local methodGeneral Materials ScienceGuided elastic wavePhysicsStructural health monitoringGuided wave testingScatteringbusiness.industryApplied MathematicsMechanical EngineeringCondensed Matter PhysicsFinite element methodDiscontinuity (linguistics)Mechanics of MaterialsComposite structureModeling and SimulationReflection (physics)Ultrasonic sensorSettore ICAR/08 - Scienza Delle CostruzionibusinessSemi-analytical finite element methodInternational Journal of Solids and Structures
researchProduct

Model Predictive Control for Shunt Active Filters With Fixed Switching Frequency

2016

This paper presents a modification to the classical Model Predictive Control algorithm, named Modulated Model Predictive Control, and its application to active power filters. The proposed control is able to retain all the advantages of a Finite Control Set Model Predictive Control whilst improving the generated waveforms harmonic spectrum. In fact a modulation algorithm, based on the cost function ratio for different output vectors, is inherently included in the MPC. The cost function-based modulator is introduced and its effectiveness on reducing the current ripple is demonstrated. The presented solution provides an effective and straightforward single loop controller, maintaining an excel…

Active filters; harmonic distortion; model predictive control (MPC); power filters; power quality; smart gridsEngineeringmodel predictive control (MPC)020209 energyRipple02 engineering and technologyIndustrial and Manufacturing EngineeringHarmonic analysisHarmonic spectrumControl theory0202 electrical engineering electronic engineering information engineeringElectronic engineeringsmart gridsWaveformElectrical and Electronic EngineeringActive filterModel Predictive ControlActive filtersTotal harmonic distortionbusiness.industry020208 electrical & electronic engineeringpower filtersAC powerpower qualityharmonic distortionModel predictive controlControl and Systems Engineeringbusiness
researchProduct

Low repetition rate gain-switched double-clad thulium-doped fiber laser operating in the 2 µm wavelength region

2021

Abstract The experimental demonstration of a gain-switched pulsed fiber laser with low repetition rate emission in the 2 µm wavelength region is presented. The laser cavity is based on the figure-9 shape, where the gain-switched operation of the laser is obtained by using a double-clad Tm-doped fiber (DCTDF) as gain medium and a commercial pulsed laser diode at 793-nm with configurable parameters as pump source. The pulse parameters of the pump source are optimized for efficient suppressing of unstable gain-switched laser oscillations. As a result, laser pulses with low repetition rate in a range from 10 to 20 kHz with laser emission at the wavelength of 1951 nm are obtained. The generated …

Active laser mediumMaterials sciencebusiness.industryPhysics::Opticschemistry.chemical_elementLaserAtomic and Molecular Physics and OpticsElectronic Optical and Magnetic Materialslaw.inventionWavelengthThuliumchemistryControl and Systems EngineeringlawFiber laserOptical cavityOptoelectronicsFiberElectrical and Electronic EngineeringbusinessInstrumentationDiodeOptical Fiber Technology
researchProduct

Reply to comment on “A MRCI PS and CASSCF study of the ground state MgO dissociation energy”

1993

To compute the dissociation energy of MgO, the relationship among the size of the active space in CASSCF wavefunctions, the computed De and the continuity of ∂E/∂r is studied. Basis set influence is also considered. Finally, it is concluded that the dissociation energy of MgO referred to ground state atoms is 2.32±0.1 eV.

Active spaceChemistryGeneral Physics and AstronomyPhysical and Theoretical ChemistryAtomic physicsWave functionGround stateBond-dissociation energyBasis setChemical Physics Letters
researchProduct

Is the nonREM–REM sleep cycle reset by forced awakenings from REM sleep?

2002

In selective REM sleep deprivation (SRSD), the occurrence of stage REM is repeatedly interrupted by short awakenings. Typically, the interventions aggregate in clusters resembling the REM episodes in undisturbed sleep. This salient phenomenon can easily be explained if the nonREM–REM sleep process is continued during the periods of forced wakefulness. However, earlier studies have alternatively suggested that awakenings from sleep might rather discontinue and reset the ultradian process. Theoretically, the two explanations predict a different distribution of REM episode duration. We evaluated 117 SRSD treatment nights recorded from 14 depressive inpatients receiving low dosages of Trimipram…

Activity CyclesMaleSelective REM sleep deprivationPolysomnographyAudiologyBehavioral NeuroscienceNIGHTSleep onset REM episodeDEPRIVATIONSlow-wave sleepmedia_commonDEPRESSIVE PATIENTSmedicine.diagnostic_testDepressionmusculoskeletal neural and ocular physiologyTRIMIPRAMINEMiddle AgedAntidepressive AgentsAnesthesiaLATENCIESFemaleWakefulnessArousalPsychologyAlgorithmspsychological phenomena and processesmedicine.drugVigilance (psychology)Adultmedicine.medical_specialtyREM episodePolysomnographymedia_common.quotation_subjectRapid eye movement sleepSleep REMExperimental and Cognitive PsychologyNon-rapid eye movement sleepmental disordersmedicineHumansWakefulnessMODULATIONUltradian rhythmINTERRUPTIONARTIFICIAL NEURAL NETWORKSRECOGNITIONTrimipramineUltradian processSleep cycleSleepEYE-MOVEMENT SLEEPPhysiology & Behavior
researchProduct

P and R Wave Detection in Complete Congenital Atrioventricular Block

2009

Complete atrioventricular block (type III AVB) is characterized by an absence of P wave transmission to ventricles. This implies that QRS complexes are generated in an autonomous way and are not coordinated with P waves. This work introduces a new algorithm for the detection of P waves for this type of pathology using non-invasive electrocardiographic surface leads. The proposed algorithm is divided into three stages. In the first stage, the R waves located by a QRS detector are used to generate the RR series and time references for the other stages of the algorithm. In the second stage, the ventricular activity (QT segment) is removed by using an adaptive filter that obtains an averaged pa…

AdultAdolescentBiomedical EngineeringYoung AdultQRS complexHeart Conduction SystemmedicineHumansSensitivity (control systems)Atrioventricular BlockChildMathematicsSeries (mathematics)P waveDetectorSignal Processing Computer-Assistedmedicine.diseaseAdaptive filterTransmission (telecommunications)Child PreschoolElectrocardiography AmbulatoryEnginyeria biomèdicaAtrioventricular blockAlgorithmAlgorithmsAnnals of Biomedical Engineering
researchProduct

Diagnostic performance of 2D-shear wave elastography in the diagnosis of breast cancer: a clinical appraisal of cutoff values

2022

Purpose To assess the role of 2D-shear wave elastography (2D-SWE) in differentiating benign from malignant focal breast lesions (FBLs), providing new vendor-specific cutoff values. Methods 158 FBLs (size: 3.5-50 mm) detected in 151 women (age: 21-87 years) were prospectively evaluated by means 2D-SWE. For each lesion, an expert radiologist assessed US BI-RADS category and calculated the following four 2D-SWE parameters: (1) elasticity maximum (E-max); (2) mean elasticity (E-mean); (3) minimum elasticity (E-min); (4) elasticity ratio (E-ratio). US-guided core-biopsy was considered as standard of reference for all the FBLs classified as BI-RADS 4 or 5. For each 2D-SWE parameter, the optimal c…

AdultAged 80 and overReproducibility of ResultsBreast NeoplasmsGeneral MedicineMiddle AgedSensitivity and SpecificityDiagnosis DifferentialYoung AdultElasticity imaging techniquesShear wave imagingHumansFemaleRadiology Nuclear Medicine and imagingUltrasonography MammaryBreastSettore MED/36 - Diagnostica Per Immagini E RadioterapiaAgedUltrasonography
researchProduct

In vivo vibrational wave propagation in human tibiae at different ages

1989

Vibrational wave propagation was tested in vivo on the tibial bone of both legs of 56 female volunteers. The impact was produced by a hammer with a force strain gauge and the response was monitored by two accelerometers. The peak amplitude of the accelerations, the velocity of the acceleration wave propagation and damping were analysed for comparison among the different age groups. The results showed significant negative correlations between age and the peak amplitude of acceleration, and the velocity of acceleration wave propagation (p less than 0.01). The damping time of the acceleration wave also had a negative correlation with age. These findings suggested that age differences were rela…

AdultAgingBone densityWave propagationPhysiologyQuantitative Biology::Tissues and OrgansPhysics::Medical PhysicsAccelerometerVibrationAccelerationOpticsPhysiology (medical)HumansOrthopedics and Sports MedicineStrain gaugeAgedBone mineralPhysicsTibiabusiness.industryPublic Health Environmental and Occupational HealthMechanicsGeneral MedicineMiddle AgedVibrationAmplitudeFemalebusinessEuropean Journal of Applied Physiology and Occupational Physiology
researchProduct

Is local stiffness, as measured by radio frequency, more sensitive than intima-media thickness?

2013

Aim: The aim of our study was to explore the changes in common carotid arterial intima-media thickness (CCA IMT) and local arterial stiffness to evaluate, non-invasively, early vascular disease in patients with cardiovascular (CV) risk factors and "normal" carotid IMT (6.05 m/s better identified, among patients with IMT <0.9mm, those with cardiovascular risk factors (sensitivity 82.0 % specificity 62.0 %; AUC 0.73). Conclusion. Increased stiffness is a result of change both in quantity and quality of the arterial wall. Arterial functional changes and distention alterations may herald the onset of vascular disease before manifestation of symptoms or detection of preclinical atherosclerotic l…

AdultCarotid Artery DiseasesMaleCarotid Artery CommonMiddle AgedPulse Wave AnalysisCardiovascular diseaseSettore MED/11 - Malattie Dell'Apparato CardiovascolareCarotid Intima-Media ThicknessElasticityCarotid intima-media thickneYoung AdultVascular StiffnessROC CurvePredictive Value of TestsRisk FactorsArea Under CurveCase-Control StudiesVascular stiffneElasticity Imaging TechniquesHumansFemaleCardiology and Cardiovascular MedicineVascular stiffnessCarotid intima-media ticknesscardiovascular diseasesInternational angiology : a journal of the International Union of Angiology
researchProduct

Possible misclassification of cardiovascular risk by SCORE in antisynthetase syndrome: results of the pilot multicenter study RI.CAR.D.A

2020

Abstract Objectives To test the ability of an established traditional cardiovascular (CV) risk prediction score [Systematic COronary Risk Evaluation (SCORE)] and its EULAR modified version (mSCORE) to identify antisynthetase syndrome (ASyS) patients at high CV risk and to examine for the first time associations of CV and cerebrovascular surrogate markers with clinical and immunological ASyS parameters. Methods SCORE/mSCORE and the gold standard marker of aortic stiffness [carotid-femoral pulse wave velocity (cfPWV)] were examined in ASyS patients and healthy controls. Moreover, sonography of the common- (CCA) and internal- (ICA) carotid arteries was performed in subsets of both groups, eval…

AdultCarotid Artery DiseasesMaleCarotid atherosclerosismedicine.medical_specialtyPilot ProjectsAntisynthetase syndrome030204 cardiovascular system & hematologyCarotid Intima-Media Thickness03 medical and health sciencesVascular Stiffness0302 clinical medicineRheumatologyInternal medicineDiabetes mellitusHumansMedicinePharmacology (medical)Prospective StudiesPulse wave velocitySubclinical infection030203 arthritis & rheumatologyMyositisbiologybusiness.industryConfoundingGold standard (test)Middle Agedmedicine.diseaseCarotid ArteriesCross-Sectional StudiesHeart Disease Risk FactorsCase-Control Studiescardiovascular systembiology.proteinCardiologyFemaleCreatine kinasebusinessRheumatology
researchProduct