Search results for "wave"
showing 10 items of 6009 documents
Effects of magnetic configuration on hot electrons in a minimum-B ECR plasma
2020
International audience; To investigate the hot electron population and the appearance of kinetic instabilities in highly charged electron cyclotron resonance ion source (ECRIS), the axially emitted bremsstrahlung spectra and microwave bursts emitted from ECRIS plasma were synchronously measured on SECRAL-II (Superconducting ECR ion source with Advanced design in Lanzhou No. II) ion source with various magnetic field configurations. The experimental results show that when the ratio of the minimum field to the resonance field (i.e. Bmin/Becr ) is less than ~0.8, the bremsstrahlung spectral temperature Ts increases linearly with the Bmin/Becr –ratio when the injection, extraction and radial mi…
Real space observation of two-dimensional Bloch wave interferences in a negative index photonic crystal cavity
2008
We report here the direct observation of two-dimensional (2D) Bloch wave interferences in a negative index photonic crystal by using optical near-field microscopy techniques. The photonic crystal is formed by a defectless honeycomb lattice of air holes etched in III-V semiconductor slab. A scanning near-field optical microscope is used to visualize spatially, as well as spectrally, the light distribution inside the photonic crystal. The recorded near-field spectra and maps presented here unambiguously demonstrate the Bloch wave interferences within the photonic crystal. Then, the spectral and spatial evolution of these interferences allows us to recover experimentally the 2D band diagram of…
A graphene-based neutral particle detector
2019
A neutral particle detector is presented, in which the traditionally used target material, indium tin oxide (ITO), is replaced by graphene. The graphene-based detector enables collinear photodetachment measurements at a significantly shorter wavelength of light down to 230 nm compared to ITO-based detectors, which are limited at 335 nm. Moreover, the background signal from the photoelectric effect is drastically reduced when using graphene. The graphene based detector, reaching 1.7 eV further into the UV energy range, allows increased possibilities for photodetachment studies of negatively charged atoms, molecules, and clusters.A neutral particle detector is presented, in which the traditio…
The role of disorder on Er3+ luminescence in Na1/2Bi1/2TiO3
2018
Abstract Photoluminescence in Er-doped NBT is studied at different temperatures. Remarkable reduction of the luminescence intensity in the green spectral range is found in the poled state comparing with the depoled state. Luminescence spectra at low temperatures reveal continuous wavelength shift of some maxima belonging to the 4 S 3/2 → 4 I 15/2 transition depending on the excitation wavelength, which is explained by large variety of different environments around Er 3+ related to the random distribution of Na + and Bi 3+ in A-sublattice of the ABO 3 perovskite structure. Poling extends the wavelength range where shift of luminescence maxima is observed in the direction of longer excitati…
Refractive index controlled by film morphology and free carrier density in undoped ZnO through sol-pH variation
2018
Abstract Zinc oxide thin films, prepared by the sol-gel process, were deposited on glass substrate using spin coating technique. The sol-pH effect on the optical parameters was studied for alkaline sol. The surface roughness was investigated by atomic force microscopy (AFM) and varied from 20 to 40 nm. The optical transmission measurements were carried out to evaluate the behavior of the extinction coefficient and the refractive index. An exponential decay of the refractive index ‘n’ as a function of wavelength was observed. The refractive index increases slightly when the pH increases to pH = 9.5 where it reaches its maximum. Beyond this value, it decreases sharply. This behavior has been …
ZnMgO-based UV photodiodes: a comparison of films grown by spray pyrolysis and MBE
2016
Detecting the UV part of the spectrum is fundamental for a wide range of applications where ZnMgO has the potential to play a central role. The shortest achievable wavelength is a function of the Mg content in the films, which in turn is dependent on the growth technique. Moreover, increasing Mg contents lead to an electrical compensation of the films, which directly affects the responsivity of the photodetectors. In addition, the metal-semiconductor interface and the presence of grain boundaries have a direct impact on the responsivity through different gain mechanisms. In this work, we review the development of ZnMgO UV Schottky photodiodes using molecular beam epitaxy and spray pyrolysis…
The Effect of the Harmonic Content Generated by AC/DC Modular Multilevel Converters on HVDC Cable Systems
2019
With the increasing penetration of renewable and decentralized energy sources into the power grid, an extended use of DC voltages is expected on both distribution and transmission levels. Generation of DC voltages by means of voltage source converters is associated with a wide spectrum of harmonic distortions at converter terminals, both on the ac and on the dc sides. This can lead to partial discharges in power cables, which deteriorate insulation material thus weakening its performance and reducing cable life-time. In the previously published paper, the effect of harmonic distortion on appearance of partial discharges in cable insulation was evaluated. Here, the study related to the PD be…
A new technique for partial discharges measurement under DC periodic stress
2017
The aim of the present work is to recognize the type of defect in insulating materials employed in DC electrical systems. This analysis, under AC stress, is carried out by using the Phase Resolved method (PRPD). While, under constant voltage stress this method cannot be performed and measurements show complexities. In order to overcome these problems, a new technique is proposed, based on the application of a periodic continuous waveform. Simulation results, carried out by using a model based on a time-variable conductance of an air void defect, showed the PRPD pattern that can be obtain. Furthermore, compared to the constant DC stress, the measurement duration became lower and the discharg…
Acoustic Wave Behavior in a Specimen Containing an Air Void Defect
2019
The PEA method is the most used technique for the space charge measurements. As is well known, this method uses pressure waves to detect the charges accumulated in solid dielectrics. Based on its working principle, the generated acoustic waves travel within PEA cell and the specimen under test in order to be finally detected by the piezoelectric sensor. For a multilayer specimen and, in particular, in case of different materials that make up the specimen, the acoustic wave reflection is inevitable. Considering that, in several cases, the reflected waves could be detected by the piezoelectric sensor before than the main signals, the PEA cell output profile could results distorted. Based on t…
An Experimental Study of Waveguide Coupled Microwave Heating with Conventional Multicusp Negative Ion Source
2015
Negative ion production with conventional multicusp plasma chambers utilizing 2.45 GHz microwave heating is demonstrated. The experimental results were obtained with the multicusp plasma chambers and extraction systems of the RFdriven RADIS ion source and the filament driven arc discharge ion source LIISA. A waveguide microwave coupling system, which is almost similar to the one used with the SILHI ion source, was used. The results demonstrate that at least one third of negative ion beam obtained with inductive RF-coupling (RADIS) or arc discharge (LIISA) can be achieved with 1 kW of 2.45 GHz microwave power in CW mode without any modification of the plasma chamber. The co-extracted electro…