Search results for "yo"

showing 10 items of 16837 documents

Analysis of complement C3 activation products in human atherosclerotic lesions.

1991

Abstract Cleavage of the complement C3 protein is essential for complement activation. Saline extracts of human atherosclerotic lesions were examined by various techniques for the presence of C3 cleavage fragments. Crossed intermediate gel immunoelectrophoresis revealed that native C3 was the predominate C3 protein in extracts and that the C3dg fragment was also detected. SDS-PAGE/ Western blot analyses of lesion extracts employing monoclonal antibodies directed at C3c and C3dg fragment determinants demonstrated molecular weight bands corresponding to the known molecular weights of all the physiologic C3 cleavage fragments, except Cab which is known to have a short half-life. After C3, the …

medicine.diagnostic_testMolecular massArteriosclerosisBlotting WesternEnzyme-Linked Immunosorbent AssayImmunoelectrophoresisArteriesComplement C3BiologyCleavage (embryo)C3-convertasePeptide FragmentsComplement systemBlotBiochemistryWestern blotComplement C3bmedicineHumansLipid particleCardiology and Cardiovascular MedicineComplement ActivationImmunoelectrophoresisAtherosclerosis
researchProduct

Multi axis representation and Euclidean distance of muscle fatigue indexes during evoked contractions

2014

International audience; In this article, we proposed a new representation of muscular fatigue during evoked muscle contractions based on fatigue indexes such as peak to peak amplitude, RMS of the M wave, mean and median frequency and fatigue index calculated from continuous wavelet transform (I CWT). These new representations of muscle fatigue using multi axis represented and Euclidean distance give better insights on changes in physiological characteristics during muscle fatigue. This technique provides a fatigue index using several muscle characteristics. The use of other kinds of fatigue characteristics as force could also be possible.

medicine.diagnostic_testMuscle fatigueSpeech recognitionMulti axis0206 medical engineeringMathematical analysis02 engineering and technologyElectromyography[ SPI.SIGNAL ] Engineering Sciences [physics]/Signal and Image processing020601 biomedical engineering[ SPI.TRON ] Engineering Sciences [physics]/Electronics[SPI.TRON]Engineering Sciences [physics]/ElectronicsEuclidean distance03 medical and health sciences0302 clinical medicineAmplitudeMuscular fatiguemedicineRepresentation (mathematics)[SPI.SIGNAL]Engineering Sciences [physics]/Signal and Image processing030217 neurology & neurosurgeryContinuous wavelet transform[SPI.SIGNAL] Engineering Sciences [physics]/Signal and Image processingMathematics
researchProduct

Cryopreserved platelets: from in vitro thrombin generation potential to in vivo safety

2015

Abstract Background: Cryopreservation of platelets (PLTs) at -80°C with dimethyl sulfoxide (DMSO) can extend their shelf life up to 2 years. Cryopreserved PLTs (CRY-PLTs) are reported to have a greater in vivo hemostatic effect than liquid-stored PLTs. Aims of this study were: i. to evaluate the thrombin generation potential of buffy coat derived cryopreserved PLTs (CRY- BC PLT) in comparison with fresh buffy coat derived platelets concentrates; ii. to determine the efficacy and safety of CRY-PLTs transfusion in hematological patients with severe thrombocytopenia. Materials and methods: BC PLTs were obtained from 5 buffy coats and pooled. The final PLTs concentrates were leukoreduced by fil…

medicine.diagnostic_testP-selectinbusiness.industryImmunologyCell BiologyHematologyBuffy coatBiochemistryThromboelastographyCryopreservationAndrologyTissue factorThrombinIn vivoImmunologymedicinethrombin generation cryopreserved platelets DMSOPlateletbusinessmedicine.drug
researchProduct

2019

Ankle plantar flexor muscles are active in the stance phase of walking to propel the body forward. Increasing walking speed requires increased plantar flexor excitation, frequently assessed using surface electromyography (EMG). Despite its popularity, validity of surface EMG applied on shank muscles is mostly unclear. Thus, we examined the agreement between surface and intramuscular EMG at a range of walking speeds. Ten participants walked overground at slow, preferred, fast, and maximum walking speeds (1.01 ± 0.13, 1.43 ± 0.19, 1.84 ± 0.23, and 2.20 ± 0.38 m s-1, respectively) while surface and fine-wire EMG activities of flexor hallucis longus (FHL), soleus (SOL), medial gastrocnemius (MG…

medicine.diagnostic_testPhysiologyStance phase030229 sport sciencesElectromyographymusculoskeletal systemPlantar flexionbody regionsLeg musclePreferred walking speed03 medical and health sciences0302 clinical medicinemedicine.anatomical_structureFlexor hallucis longusPhysiology (medical)medicineAnkle030217 neurology & neurosurgeryBiomedical engineeringLateral gastrocnemiusFrontiers in Physiology
researchProduct

Concentric force enhancement during human movement

2001

In order to understand the possible mechanisms contributing to enhanced concentric performance in stretch-shortening cycle exercises in vivo the present study examined knee extension torque, electromyogram (EMG) activity and fascicle length of the vastus lateralis muscle in maximal and submaximal human movements. Maximal concentric knee extensions (120 degrees s(-1)) were done after pre-stretch and pre-isometric conditions by nine volunteers. During shortening at the knee angle of 115 degrees (180 degrees = extended) the knee extension torque was found to be greater in pre-stretch condition (272 vs. 248 N m, P < 0.05) although the torque level prior to shortening was smaller than in pre-iso…

medicine.diagnostic_testPhysiologyVastus lateralis muscleElectromyographyAnatomyFascicleConcentricmedicine.disease_causeStretch shortening cycleJumpingmedicineEccentricmedicine.symptomBiomedical engineeringMuscle contractionMathematicsActa Physiologica Scandinavica
researchProduct

Letters to the editor

1992

medicine.diagnostic_testPhysiologybusiness.industryOrganophosphateDepolarizationElectromyographyCellular and Molecular Neurosciencechemistry.chemical_compoundElectrophysiologychemistryPhysiology (medical)MedicineNeurology (clinical)Repetitive nerve stimulationbusinessNeuroscienceElectric stimulationMuscle &amp; Nerve
researchProduct

Bestimmung der myokardialen Perfusionsreserve bei KHK-Patienten mit der kontrastmittelverstärkten MRT: Ein Vergleich zwischen semiquantitativer und q…

2002

OBJECTIVE Comparison between two semiquantitative methods and a quantitative evaluation of myocardial blood flow (MBF) for assessment of myocardial perfusion reserve (MPR) in patients with CAD. MATERIAL AND METHODS 9 patients with coronary stenoses > 50 % were examined with an ECG-gated Saturation Recovery Turbo FLASH sequence by using Gd-DTPA as contrast agent (CA). The entive measurements were performed both during rest and hyperemia induced by adenosine. The up-slopes of the signal-time S(t) curves in the myocardium and left ventricular (LV) cavity were evaluated by a linear fit. MPR was calculated from the original up-slopes of the myocardial S(t) curves and from the up-slopes, which we…

medicine.diagnostic_testbusiness.industryIschemic myocardiumIschemiaSaturation recoveryMagnetic resonance imagingBlood flowPerfusion reservemedicine.diseaseMedicineRadiology Nuclear Medicine and imagingIn patientbusinessNuclear medicinePerfusionRöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren
researchProduct

Characterization of normal regional myocardial function by MRI cardiac tagging

2013

Purpose The aim of this study was to establish reference values for segmental myocardial strain measured by magnetic resonance (MR) cardiac tagging in order to characterize the regional function of the heart. Material and Methods We characterized the left ventricular (LV) systolic deformation in 39 subjects (26 women and 13 men, age 58.8 ± 11.6 years) whose cardiological study had not revealed any significant abnormality. The deformation was measured from MR-tagged (Siemens 1.5T MR) images using an algorithm based on sine wave modeling. Circumferential and radial peak systolic strain values along with the torsion angle and circumferential-longitudinal (CL) shear were determined in 16 LV seg…

medicine.diagnostic_testbusiness.industryMagnetic resonance imagingMyocardial functionCircumferenceApex (geometry)Myocardial strainCircumferential strainMedicineRadiology Nuclear Medicine and imagingNuclear medicinebusinessRadial stressCardiac imagingJournal of Magnetic Resonance Imaging
researchProduct

Antibodies to cell surface ganglioside GD3 perturb inductive epithelial-mesenchymal interactions

1988

Abstract Most epithelial sheets emerge during embryogenesis by a branching and growth of the epithelium. The surrounding mesenchyme is crucial for this process. We report that branching morphogenesis and the formation of a new epithelium from the mesenchyme in the embryonic kidney can be blocked by a monoclonal antibody reacting with a surface glycolipid, disialoganglioside G D3 . In contrast, a more than 10-fold excess of antibodies to adhesive glycoproteins (N-CAM, L -CAM, fibronectin) fails to inhibit morphogenesis. Although the anti-G D3 antibody affected epithelial development, the disialoganglioside G D3 was expressed not in the epithelium, but in the mesenchyme surrounding the develo…

medicine.drug_classMesenchymeMorphogenesisFluorescent Antibody TechniqueBiologyKidneyMonoclonal antibodyEpitheliumGeneral Biochemistry Genetics and Molecular BiologyMesodermMiceOrgan Culture TechniquesCell–cell interactionGangliosidesMorphogenesismedicineAnimalsGanglioside GD3Embryonic InductionMembrane GlycoproteinsAntibodies MonoclonalEmbryonic stem cellEpitheliumFibronectinsCell biologyFibronectinmedicine.anatomical_structureBiochemistryAntigens Surfacebiology.proteinUreterCell Adhesion MoleculesCell
researchProduct

Demonstration of P29, an oestrogen receptor-associated tumor marker, in human term placenta.

1991

A Mr29,000 serine phosphoprotein (P29) related to oestradiol receptor was studied in human term placenta with the use of a specific monoclonal antibody (D5). D5 was used with two different methods, immunohistochemistry and immunoradiometry. For immunohistochemistry, an indirect immunoperoxidase method was chosen to detect P29 in methacarn-fixed, wax-embedded sections. P29 was mostly confined to the syncytiotrophoblast surrounding placental villi, staining being positive in both cytoplasm and nuclei. The stroma of villi was negative. Content of P29 was uniformly high in crude placental cytosol, as measured by immunoradiometry assays. Specificity of D5 against P29 in placenta was tested by an…

medicine.drug_classPlacentaBiologyMonoclonal antibodySyncytiotrophoblastPregnancyPlacentamedicineBiomarkers TumorSerineHumansHeat-Shock ProteinsImmunoperoxidaseObstetrics and GynecologyAntibodies MonoclonalPhosphoproteinsMolecular biologyImmunohistochemistryStainingTrophoblastsmedicine.anatomical_structureReproductive MedicineReceptors EstrogenCytoplasmPhosphoproteinembryonic structuresImmunohistochemistryFemaleImmunoradiometric AssayDevelopmental BiologyPlacenta
researchProduct