Is it time to consider visual feedback systems the gold standard for chest compression skill acquisition?
Cardiopulmonary resuscitation in prone position: A scoping review.
Introduction The ongoing pandemic of COVID-19 brought to the fore prone positioning as treatment for patients with acute respiratory failure. With the increasing number of patients in prone position, both spontaneously breathing and mechanically ventilated, cardiac arrest in this position is more likely to occur. This scoping review aimed to summarize the available evidence on cardiopulmonary resuscitation in prone position (‘reverse CPR’) and knowledge or research gaps to be further evaluated. The protocol of this scoping review was prospectively registered on 10th May 2020 in Open Science Framework (https://osf.io/nfuh9). Methods We searched PubMed, EMBASE, MEDLINE and pre-print repositor…
Mortality after in-hospital cardiac arrest in patients with COVID-19: A systematic review and meta-analysis.
Abstract Aim To estimate the mortality rate, the rate of return of spontaneous circulation (ROSC) and survival with favorable neurological outcome in patients with COVID-19 after in-hospital cardiac arrest (IHCA) and attempted cardiopulmonary resuscitation (CPR). Methods PubMed, EMBASE, Web of Science, bioRxiv and medRxiv were surveyed up to 8th February 2021 for studies reporting data on mortality of patients with COVID-19 after IHCA. The primary outcome sought was mortality (in-hospital or at 30 days) after IHCA with attempted CPR. Additional outcomes were the overall rate of IHCA, the rate of non-shockable presenting rhythms, the rate of ROSC and the rate of survival with favorable neuro…
Protocol of a multicenter international randomized controlled manikin study on different protocols of cardiopulmonary resuscitation for laypeople (MANI-CPR)
IntroductionOut-of-hospital cardiac arrest is one of the leading causes of death in industrialised countries. Survival depends on prompt identification of cardiac arrest and on the quality and timing of cardiopulmonary resuscitation (CPR) and defibrillation. For laypeople, there has been a growing interest on hands-only CPR, meaning continuous chest compression without interruption to perform ventilations. It has been demonstrated that intentional interruptions in hands-only CPR can increase its quality. The aim of this randomised trial is to compare three CPR protocols performed with different intentional interruptions with hands-only CPR.Methods and analysisThis is a prospective randomise…
Intentional interruptions during compression only CPR: a way to increase adherence to CPR and compressions' quality?
Out-of-hospital cardiac arrest during the COVID-19 era: The importance to fight against fear
Real-time feedback systems for cardiopulmonary resuscitation training: time for a paradigm shift.
Among the new tools to improve the quality of cardiopulmonary resuscitation (CPR), real-time feedback systems (FS) have been largely studied during the last decade (1). These systems permit the real-time analysis of CPR.
Physical activity and quality of cardiopulmonary resuscitation: A secondary analysis of the MANI-CPR trial
Abstract Introduction The association between the level of physical activity and quality of cardio-pulmonary resuscitation (CPR) performed by laypeople is unclear. The aim of this study was to evaluate the associations between physical activity level and laypeople performance during an eight-minute scenario of CPR. Materials and methods This study was a secondary analysis of the MANI-CPR Trial. The entire cohort of participants was grouped based on the level of physical activity assessed using the International Physical Activity Questionnaire (IPAQ) into a “low-moderate” level group and a “high” level group. Descriptive statistics were used for unadjusted analysis and multivariate logistic …
The challenge of laypeople cardio-pulmonary resuscitation training during and after COVID-19 pandemic.
Cardiac arrest and coronavirus disease 2019
The impact of the coronavirus disease 2019 (COVID-19) on the cardiovascular system has been highlighted since the very first weeks after the severe acute respiratory syndrome coronavirus 2 identification. We reviewed the influence of COVID-19 pandemic on cardiac arrest, both considering those occurred out of the hospital (OHCA) and in the hospital (IHCA).An increase in OHCA incidence occurred in different countries, especially in those regions most burdened by the COVID-19, as this seems to be bounded to the pandemic trend. A change of OHCA patients' characteristics, with an increase of the OHCA occurred at home, a decrease in bystander cardiopulmonary resuscitation and automated external d…
A Multicenter International Randomized Controlled Manikin Study on Different Protocols of Cardiopulmonary Resuscitation for Laypeople: The MANI-CPR Trial.
Background Compression-only cardiopulmonary resuscitation (CPR) is a suggested technique for laypeople facing out-of-hospital cardiac arrest (OHCA). However, it is difficult performing high-quality CPR until emergency medical services arrival with this technique. We aimed to verify whether incorporating intentional interruptions of different frequency and duration increases laypeople's CPR quality during an 8-minute scenario compared with compression-only CPR. Methods We performed a multicenter randomized manikin study selecting participants from 2154 consecutive laypeople who followed a basic life support/automatic external defibrillation course. People who achieved high-quality CPR in 1-m…
Additional file 1: of Is it time to consider visual feedback systems the gold standard for chest compression skill acquisition?
Shows the graphic interface of the Laerdal QCPRÂŽ feedback system. Screenshot representing how Laerdal QCPRÂŽ provides real-time visual feedback during training. In this case, compressions are too shallow, 40Â mm for the last one, with incomplete chest recoil (another yellow arrow suggests you should allow complete chest recoil), and the compression rate is too low, 84 compressions/minute (a continuous yellow line shows that the compressions are not in the correct range). The system recognizes as correct parameters those recommended by international guidelines. (TIFF 123 kb)