Iris-fixated toric phakic intraocular lens: Three-year follow-up

2006

Purpose To evaluate the 3-year safety, efficacy, predictability, and stability of iris-fixated toric phakic intraocular lens (pIOL) implantation for the correction of myopia or hyperopia with astigmatism. Setting Department of Ophthalmology, Johannes Gutenberg University, Mainz, and Department of Ophthalmology, University Clinic, Bochum, Germany. Methods A prospective clinical trial of 40 eyes of 23 patients with high ametropia and astigmatism was conducted. Best spectacle-corrected visual acuity (BSCVA), uncorrected visual acuity, refraction, astigmatism, intraocular pressure, slitlamp biomicroscopy, and indirect ophthalmoscopy were measured preoperatively and postoperatively. Results Of t…

AdultMalemedicine.medical_specialtyIntraocular pressureVisual acuitygenetic structuresmedicine.medical_treatmentVisual AcuityIrisIntraocular lensAstigmatismRefraction OcularPhakic intraocular lensOphthalmoscopyPostoperative ComplicationsLens Implantation IntraocularOphthalmologyLens CrystallineHumansMedicineProspective StudiesIntraoperative ComplicationsIntraocular PressureDioptremedicine.diagnostic_testbusiness.industryAstigmatismMiddle Agedmedicine.diseaseeye diseasesSensory SystemsRefractive Surgical ProceduresOphthalmoscopyToric lensOphthalmologyTreatment OutcomeFemaleSurgerysense organsmedicine.symptombusinessFollow-Up StudiesJournal of Cataract and Refractive Surgery
researchProduct

Changes in higher-order aberrations after implantation of a foldable iris-claw lens in myopic phakic eyes

2006

Purpose To evaluate the change in higher-order aberrations (HOAs) after implantation of a foldable iris-claw phakic intraocular lens (pIOL) in myopic eyes. Setting Department of Ophthalmology, Johannes Gutenberg-University, Mainz, Germany. Methods This prospective nonrandomized comparative self-controlled trial included 41 eyes that had implantation of a foldable iris-claw pIOL between July 2003 and November 2004. All patient data for HOAs (Zernike coefficient) were measured and calculated using the same pupil size preoperatively and postoperatively, and the root-mean-square (RMS) wavefront error was calculated. Examinations were performed preoperatively as well as 1 week and 3, 6, and 12 m…

medicine.medical_specialtyRefractive errorgenetic structuresAnterior ChamberEye diseaseVisual AcuityIrisPhakic intraocular lensCorneaVision disorderLens Implantation IntraocularOphthalmologyLens CrystallineMyopiaHumansMedicineProspective StudiesIris clawDioptreLenses Intraocularbusiness.industryRefractive Errorsmedicine.diseaseeye diseasesSensory SystemsOphthalmologyAberrations of the eyemedicine.anatomical_structureLens (anatomy)Silicone ElastomersSurgerysense organsmedicine.symptombusinessJournal of Cataract and Refractive Surgery
researchProduct

The "sandwich technique" for iris-fixated phakic intraocular lens implantation.

2006

ABSTRACT PURPOSE: To describe a new technique of implantation of the Artisan/Verisyse phakic intraocular lens (PIOL). METHODS: After PIOL insertion into the anterior chamber, a bolus of a high viscosity ophthalmic viseosurgical device (OVD) is placed over the optic, separating it widely from the endothelium. RESULTS: The technique decreases the chance of endothelial damage during enclavation. CONCLUSIONS: A bolus of a high viscosity OVD placed on the anterior surface of the Artisan/Verisyse PIOL may make enclavation safer. [J Refract Surg. 2006;22:96-98.]

medicine.medical_specialtygenetic structuresbusiness.industryAnterior Chambermedicine.medical_treatmentSuture TechniquesIrisIntraocular lensAnterior surfacePhakic intraocular lensRefractive Surgical ProceduresOphthalmologyLens Implantation IntraocularOphthalmologymedicineHumansSurgerybusinessSandwich techniqueJournal of refractive surgery (Thorofare, N.J. : 1995)
researchProduct

Incisional Keratotomy to Toric Intraocular Lenses: An Overview of the Correction of Astigmatism in Cataract and Refractive Surgery

2003

Lenses Intraocularmedicine.medical_specialtybusiness.industrymedicine.medical_treatmentAstigmatismCataract ExtractionAstigmatismmedicine.diseasePhotorefractive KeratectomyRefractive Surgical ProceduresCorneaOphthalmologyPostoperative ComplicationsLens Implantation IntraocularIntraocular lensesOphthalmologyRefractive surgerymedicineHumansLasers ExcimerbusinessKeratotomy RadialInternational Ophthalmology Clinics
researchProduct

Postoperative astigmatism and rotational stability after Artisan toric phakic intraocular lens implantation

2003

Abstract Purpose To evaluate deviations in the axis (intended versus achieved) and postoperative astigmatism after implantation of an Artisan toric phakic intraocular lens (IOL). Setting University Eye Hospital, Mainz, Germany. Methods This prospective study comprised 29 eyes with high ametropia and astigmatism. All eyes had uneventful implantation of a toric phakic IOL through a superior scleral tunnel incision at 12 o’clock. After a minimum of 6 months, the uncorrected visual acuity (UCVA), best correct visual acuity, refraction, and astigmatism were analyzed in all eyes. A multivariate analysis of postoperative astigmatism was performed. Results After a follow-up of at least 6 months, 95…

AdultMaleRefractive errorVisual acuityRotationgenetic structuresmedicine.medical_treatmentEmmetropiaIntraocular lensPhakic intraocular lensLens Implantation IntraocularmedicineHumansPostoperative PeriodProspective StudiesDioptreLenses Intraocularbusiness.industryAstigmatismEquipment DesignMiddle AgedRefractive Errorsmedicine.diseaseeye diseasesSensory SystemsRefractive Surgical ProceduresToric lensOphthalmologyMeridian (perimetry visual field)OptometryFemaleSurgerysense organsmedicine.symptombusinessJournal of Cataract and Refractive Surgery
researchProduct

Kosteneffektivitätsanalyse der Versorgung von Kataraktpatienten mit monofokalen Intraokularlinsen aus Sicht der Leistungserstatter

2003

BACKGROUND Data on the cost effectiveness of cataract surgery with respect to the German statutory health insurance system are hardly available. Hence the increase in visual acuity as primary efficacy endpoint, order of posterior capsule opacification as primary complication endpoint and direct cost for supplementation with monofocal intraocular lenses have been assessed via meta-analyses to evaluate the procedure's cost effectiveness from the perspective of the German statutory health insurance system. MATERIAL AND METHODS Using the medical internet database MEDLINE two meta-analyses on publications between 1995 and 2002 were carried out, one estimating the gained increase in visual acuity…

Visual acuitygenetic structuresCost effectivenessbusiness.industrymedicine.medical_treatmentEye diseaseOutpatient surgeryIntraocular lensCataract surgerymedicine.diseaseeye diseasesOphthalmologyInterquartile rangeMedicineOptometrymedicine.symptombusinessIncremental cost-effectiveness ratioKlinische Monatsblätter für Augenheilkunde
researchProduct

Scheimpflug biometry of the anterior segment after implantation of foldable iris-fixated lenses.

2006

ABSTRACT PURPOSE: To evaluate intraocular dimensions of the anterior segment of myopic phakic eyes after implantation of foldable iris-fixated lenses. METHODS: Seventeen myopic eyes that received a foldable iris-fixated phakic intraocular lens (PIOL) were assessed. Distances between the cornea and the IOLoptic edge and between the IOL optic and the crystalline lens were evaluated using Scheimpf lug photography 3 months postoperatively. RESULTS: The average postoperative distance between the central corneal endothelium and the anterior surface of the IOL was 2.01±0.26 mm. The distance between the corneal endothelium and the peripheral edge of the IOL averaged 1.32±0.18 mm at the 12 o'clock p…

AdultMalemedicine.medical_specialtyCorneal endotheliumBiometrygenetic structuresScheimpflug principleIrisAnterior surfacePhakic intraocular lensRefraction Ocularlaw.inventionLens Implantation IntraocularlawAnterior Eye SegmentCorneaOphthalmologyLens CrystallinemedicineMyopiaPhotographyHumansIris (anatomy)Retrospective StudiesLenses Intraocularbusiness.industrySuture Techniqueseye diseasesLens (optics)Ophthalmologymedicine.anatomical_structureSurgeryFemalesense organsbusinessFollow-Up StudiesJournal of refractive surgery (Thorofare, N.J. : 1995)
researchProduct

Impact of the line of sight on toric phakic intraocular lenses for hyperopia

2003

We present a hyperopic patient with a decentered line of sight in whom the residual refractive error after toric phakic intraocular lens (TP IOL) implantation was improved by displacement and individualized treatment. A 35-year-old woman presented with asthenopic complaints 2 months after bilateral TP IOL implantation and IOL rotation 4 weeks later. Examination revealed the line of sight to be nasally and inferiorly decentered in relation to the center of the pupil. A more nasal reenclavation of the TP IOL decreased the coma, and the uncorrected visual acuity was 20/20. We conclude that line of sight should be measured before TP IOL implantation, especially in hyperopic eyes.

AdultReoperationRefractive errormedicine.medical_specialtygenetic structuresEye diseasemedicine.medical_treatmentVision DisordersVisual AcuityComa (optics)Intraocular lensUncorrected visual acuityPhakic intraocular lensPupilVision disorderForeign-Body MigrationLens Implantation IntraocularOphthalmologyLens CrystallinemedicineHumansbusiness.industryAstigmatismCorneal TopographyPupilmedicine.diseaseeye diseasesSensory SystemsOphthalmologyHyperopiaOptometryFemaleSurgeryAsthenopiasense organsmedicine.symptombusinessJournal of Cataract and Refractive Surgery
researchProduct

Preoperative simulation of postoperative iris-fixated phakic intraocular lens position and simulation of aging using high-resolution Scheimpflug imag…

2006

To increase postoperative safety after implantation of iris-fixated phakic intraocular lenses (pIOLs), optimal preoperative evaluation and patient selection is mandatory. We present a new software tool in a high-resolution Scheimpflug imaging device that precisely simulates the postoperative position of an iris-fixated pIOL and also simulates the effect of aging on the pIOL's position.

AdultAgingmedicine.medical_specialtygenetic structuresmedicine.medical_treatmentSoftware toolScheimpflug principleIrisHigh resolutionIntraocular lensPhakic intraocular lensPreoperative careImaging Three-DimensionalLens Implantation IntraocularAnterior Eye SegmentOphthalmologyLens CrystallinePreoperative CaremedicineHumansComputer SimulationPostoperative PeriodIris (anatomy)Lens crystallinebusiness.industryeye diseasesSensory SystemsOphthalmologymedicine.anatomical_structureFemaleSurgerysense organsbusinessJournal of Cataract and Refractive Surgery
researchProduct

Phacoemulsification and Vitrectomy with the Erbium: or Neodymium:YAG-Laser

2002

Summary There are an increasing number of applications for Erbium:YAG and Neodymium:YAG lasers in opthalmology. Laser phacoemulsification and Erbium-laser vitrectomy are of major interest. We report the underlying technology and more than 1-year-experience using the PHACOLASE (Carl Zeiss Meditec, Jena, Germany, 10–100 Hz frequency, 5–50 mJ single pulse energy) for phacoemulsification and pars plana vitrectomy and the Lyla-Dodick laser photolysis (A.R.C. Laser, Eckental-Forth, Germany, 1–20 Hz, up to 8 mJ single pulse energy). The Erbium:YAG laser and Neodymium:YAG laser enabled us to extract lenses with up to medium hard nuclei. Moreover, the Erbium laser enabled fast vitrectomy with little…

Pars planaMaterials sciencebusiness.industrymedicine.medical_treatmentchemistry.chemical_elementVitrectomyDermatologyPhacoemulsificationCataract surgeryLaserNeodymiumlaw.inventionErbiummedicine.anatomical_structureOpticschemistrylawmedicineNeodymium-YAG laserSurgerybusinessMedical Laser Application
researchProduct

Capsule measuring ring to predict capsular bag diameter and follow its course after foldable intraocular lens implantation

2003

Purpose: To evaluate the extent of capsular bag shrinkage after cataract surgery with intraocular lens (IOL) implantation and develop a regression formula to predict postoperative capsular bag size. Setting: Eye Hospital, Johannes Gutenberg-University, Mainz, Germany. Methods: The axial length (AL), anterior chamber depth, and corneal radius in 58 eyes were measured preoperatively. Cataract surgery was by phacoemulsification followed by implantation of a 3-piece, acrylic, posterior chamber IOL. The capsular bag diameter and anterior capsulorhexis were measured intraoperatively and 1 day and 1, 3, and 6 months postoperatively using a Koch capsule measuring ring (HumanOptics). Results: The me…

Malemedicine.medical_specialtymedicine.medical_treatmentAcrylic ResinsLens Capsule CrystallineIntraocular lensPositive correlationCorneaPostoperative ComplicationsLens Implantation IntraocularOphthalmologymedicineHumansCapsulorhexisShrinkageLenses IntraocularPhacoemulsificationbusiness.industryCapsulePhacoemulsificationCataract surgeryCapsulorhexisSensory SystemsOphthalmologyCapsular bagFemaleSurgerybusinessJournal of Cataract and Refractive Surgery
researchProduct

Evaluation of cut quality using the Amadeus microkeratome with different settings.

2004

Abstract Purpose: To evaluate the quality of keratectomy specimens created with the Amadeus® microkeratome (AMO) using scanning electron microscopy (SEM). Setting: Johannes Gutenberg-University Hospital, Department of Ophthalmology, Mainz, and the Department of Anatomy, Justus Liebig-University, Giessen, Germany. Methods: Corneal cuts were performed in freshly enucleated pig eyes using the Amadeus microkeratome with 9 combinations of oscillation rate and head-advance speed. For the cutting trials, oscillation rates of 8000, 13000, and 18000 rpm and head-advance speeds of 1.0, 2.5, and 4.0 mm/s were chosen. Fifty-four eyes were included, resulting in 9 groups of 6 eyes for each configuration…

Quality Controlbusiness.industryOscillationSwinemedicine.medical_treatmentCorneal StromaKeratomileusis Laser In SituKeratomileusisSurface smoothnessSensory SystemsSurgical FlapsOphthalmologyQuality (physics)OpticsEvaluation Studies as TopicMicrokeratomeRefractive surgerySurface roughnessmedicineMicroscopy Electron ScanningAnimalsSurgerybusinessMathematicsJournal of cataract and refractive surgery
researchProduct

Implantation of a custom intraocular lens with a 30-diopter torus for the correction of high astigmatism after penetrating keratoplasty.

2003

Abstract We present a 62-year-old woman who had implantation of an intraocular lens (IOL) with a torus of 30.0 diopters (D) in an eye after penetrating keratoplasty. The patient presented with cataract and a best corrected visual acuity of 20/400. Penetrating keratoplasty was performed in 1975 because of decompensated keratoconus. With a clear but inferiorly decentered corneal graft, visual acuity was limited because of keratoplasty-related high corneal astigmatism of 22.5@156 that could not be successfully treated with spectacles or contact lenses. A custom toric IOL with –30.0 D of cylindrical power was implanted in the capsular bag via a sclerocorneal tunnel incision. Additionally, a sph…

medicine.medical_specialtyKeratoconusRefractive errorVisual acuitygenetic structuresmedicine.medical_treatmentEye diseaseVisual AcuityIntraocular lensAstigmatismKeratoconusProsthesis DesignCataractHigh astigmatismLens Implantation IntraocularOphthalmologymedicineHumansDioptreLenses IntraocularPhacoemulsificationbusiness.industryAstigmatismCorneal TopographyMiddle Agedmedicine.diseaseeye diseasesSensory SystemsOphthalmologyOptometrySurgeryFemalesense organsmedicine.symptombusinessKeratoplasty PenetratingJournal of cataract and refractive surgery
researchProduct

Surgical management of acute angle-closure glaucoma after toric implantable contact lens implantation

2006

A case of pupillary block after implantation of an implantable contact lens (ICL) is reported, and surgical management and prevention are discussed. In a myopic patient, the best corrected visual acuity in the right eye was 20/50 with -15.50 -3.00 x 175. After uneventful implantation of an ICL, painful acute glaucoma developed with an intraocular pressure beyond measurable values. Apparent anterior vaulting of the ICL suggested a sizing problem. In a situation of a mid-wide dilated pupil, immediate explantation of the ICL was performed. Then, using a preoperative iris photography as guidance, an anterior chamber iris-claw toric phakic intraocular lens was implanted. On postoperative examina…

Reoperationmedicine.medical_specialtyIntraocular pressuregenetic structuresContact LensesVisual AcuityPhakic intraocular lensPupilLens Implantation IntraocularOphthalmologyMyopiamedicineHumansIris (anatomy)Device RemovalIntraocular PressurePupillary blockbusiness.industryeye diseasesSensory SystemsSurgeryOphthalmologymedicine.anatomical_structureIris DiseasesAcute angle-closure glaucomaImplantable Contact LensLens (anatomy)Acute DiseaseSurgerysense organsGlaucoma Angle-ClosurebusinessJournal of Cataract and Refractive Surgery
researchProduct

Endothelial cell loss after toric iris-fixated phakic intraocular lens implantation: three-year follow-up.

2007

ABSTRACT PURPOSE: To study quantitative changes in endothelial cell count after implantation of the toric iris-fixated phakic intraocular lens. METHODS: A prospective, non-randomized, self-controlled clinical trial was conducted of 40 eyes (28 myopic, 12 hyperopic) of 23 patients with high ametropia and astigmatism. Non-contact computer-assisted endothelial microscopy was performed before and I1 2, and 3 years after surgery. RESULTS: In the myopic group, mean preoperative endothelial cell count was 3179±531 cells/mm p 2 (range: 1800 to 3900 cells/mm2). The mean intraindividual endothelial cell loss was -1.83±2.25% (range: -9.09% to 0%) in the first year; -1.83+2.95% (range: -7.74% to 3.80%)…

AdultMalemedicine.medical_specialtyTime FactorsIrisCell CountAstigmatismPhakic intraocular lensEndothelial cell countCorneal DiseasesPostoperative ComplicationsLens Implantation IntraocularOphthalmologyLens CrystallineMedicineHumansProspective Studiesbusiness.industryEndothelium CornealSuture TechniquesMiddle Agedmedicine.diseaseCell lossRefractive Surgical ProceduresEndothelial stem cellOphthalmologySurgeryFemalebusinessFollow-Up StudiesJournal of refractive surgery (Thorofare, N.J. : 1995)
researchProduct

Refractive lens exchange with an array multifocal intraocular lens.

2002

ABSTRACT PURPOSE: To prospectively evaluate safety, efficacy, predictability, stability, complications, and patient satisfaction after refractive lens exchange (clear lens extraction) followed by posterior chamber implantation of a multifocal intraocular lens (IOL). METHODS: Fifty eyes of 25 patients (mean age 51 years, range 44 to 62 years) with preoperative spherical equivalent refraction between -15.50 and +5.75 D and cylinder between 0 and 1.50 D underwent bilateral implantation of a zonal progressive multifocal IOL (Array, AMO). RESULTS: Eyes were divided into group A (n=24; myopia, average preoperative spherical equivalent refraction -7.11 ± 3.25 D (-1.75 to -15.50 D), and group B (n=…

AdultMalemedicine.medical_specialtyIntraocular pressureVisual acuitygenetic structuresmedicine.medical_treatmentVisual AcuityIntraocular lensRefractive lens exchangeRefraction Ocularlaw.inventionPostoperative ComplicationsLens Implantation IntraocularlawOphthalmologymedicineMyopiaHumansProspective StudiesIntraocular PressureLenses IntraocularClear lens extractionbusiness.industryMultifocal intraocular lensMiddle AgedRefractioneye diseasesSurgeryLens (optics)OphthalmologyHyperopiaTreatment OutcomePatient SatisfactionSurgeryFemalesense organsmedicine.symptomSafetybusinessJournal of refractive surgery (Thorofare, N.J. : 1995)
researchProduct

Late postoperative opacification of MemoryLens hydrophilic acrylic intraocular lenses Case series and review

2003

Abstract Purpose: To report clinical and spectrographic analyses of 2 explanted hydrophilic acrylic intraocular lenses (IOLs). Setting: John A. Moran Eye Center, Salt Lake City, Utah, USA, and Johannes Gutenberg-University, Department of Ophthalmology, Mainz, Germany. Methods: We report 6 cases of opacification of MemoryLens ® IOLs (Ciba Vision) that occurred approximately 2 years after implantation. The anterior and posterior surfaces of the IOLs had a white, frosted appearance, and the IOLs' interior looked brown, similar to the appearance of a brunescent cataract. Two of the IOLs were explanted because of a significant decrease in visual acuity. The IOLs were sent for further clinicopath…

Malemedicine.medical_specialtyVisual acuitygenetic structuresmedicine.medical_treatmentAcrylic ResinsVision DisordersVisual AcuityIntraocular lensSalt lakeLens Implantation IntraocularDevice removalOphthalmologymedicineHumansDevice RemovalAgedAged 80 and overLenses IntraocularPhacoemulsificationElectron probe microanalysisbusiness.industryCalcinosisPhacoemulsificationeye diseasesSensory SystemsProsthesis FailureOphthalmologyIntraocular lensesCalciumFemaleSurgerysense organsBrunescent cataractmedicine.symptombusinessElectron Probe MicroanalysisJournal of Cataract & Refractive Surgery
researchProduct

Comparison of biometric measurements using partial coherence interferometry and applanation ultrasound

2003

Abstract Purpose To compare and contrast axial length (AL) measurements assessed by ultrasound biometry and optical biometry. Setting Department of Ophthalmology, Johannes Gutenberg-University, Mainz, Germany. Methods Optical biometry and ultrasound biometry were performed in 360 eyes to measure AL. Results In eyes with a clear-appearing crystalline lens, there was a statistically significant median difference in AL measurements between the 2 methods in eyes with a normal or long length. In eyes with cataract, there was a statistically significant median difference in AL measurements in eyes with a normal or short length. In these cases, optical biometry produced larger readings than ultras…

medicine.medical_specialtyBiometryPseudophakiagenetic structuresBiometricsmedia_common.quotation_subjectmedicine.medical_treatmentEye diseaseIntraocular lensDiagnostic Techniques OphthalmologicalEyeCataractlaw.inventionOptical biometrylawOphthalmologyLens CrystallinemedicineHumansContrast (vision)Ultrasonographymedia_commonbusiness.industryUltrasoundReproducibility of Resultsmedicine.diseaseeye diseasesSensory SystemsLens (optics)OphthalmologyInterferometryPartial coherence interferometryOptometrySurgerysense organsbusinessJournal of Cataract and Refractive Surgery
researchProduct

Short-term Follow-up after Implantation of a Foldable Iris-Fixated Intraocular Lens in Phakic Eyes

2005

Objective To evaluate efficiency, predictability, stability, complications, and patient satisfaction after implantation of a foldable iris-fixated phakic intraocular lens (PIOL) for the correction of myopia. Design Prospective, nonrandomized, comparative (self-controlled) trial. Participants Forty-one eyes of 22 myopic patients aged 18 to 56 years (mean, 36 years) with average sphere of −8.2±2.01 diopters (D; range, −12.25 to −3.75 D) and average preoperative cylinder of −0.90±0.62 D (range, −2.50 to 0.00 D) were enrolled in this prospective study. Methods All eyes underwent implantation of a foldable iris-fixated PIOL with an optical zone of 6.0 mm. The follow-up was 6 months in all cases.…

AdultMaleIntraocular pressuremedicine.medical_specialtyVisual acuityAdolescentgenetic structuresmedicine.medical_treatmentVisual AcuityIrisCell CountIntraocular lensProsthesis DesignPhakic intraocular lensLens Implantation IntraocularOphthalmologyLens CrystallineMyopiaHumansMedicineProspective StudiesIris (anatomy)Intraoperative ComplicationsProspective cohort studyIntraocular PressureDioptreLenses Intraocularbusiness.industryEndothelium CornealMiddle Agedeye diseasesIndirect ophthalmoscopyOphthalmologymedicine.anatomical_structureFemalesense organsmedicine.symptombusinessFollow-Up StudiesOphthalmology
researchProduct

Change in pupil size after implantation of an iris-fixated toric phakic intraocular lens

2005

Purpose To evaluate the changes in pupil size after implantation of an iris-supported toric phakic intraocular lens (TPIOL) for correction of myopia and hyperopia with astigmatism. Setting Department of Ophthalmology, Johannes Gutenberg-University, Mainz, Germany. Methods Twenty-two myopic eyes and 9 hyperopic eyes were included in the study. The mean age of the 2 groups was 34 years and 40 years, respectively. The scotopic pupil size was measured with a handheld infrared pupillometer (Colvard, Oasis Medical) before and 6 months after implantation of the TPIOL. All examinations were performed under scotopic conditions after 2 minutes of dark adaptation with the fellow eye covered. Intraindi…

AdultMalemedicine.medical_specialtygenetic structuresmedicine.medical_treatmentIrisMagnificationIntraocular lensAstigmatismProsthesis DesignPhakic intraocular lensPupilLens Implantation IntraocularOphthalmologyLens CrystallineMyopiaMydriasismedicineHumansIris (anatomy)Lenses Intraocularbusiness.industrySuture TechniquesAstigmatismPupilMiddle Agedmedicine.diseaseeye diseasesSensory SystemsToric lensOphthalmologyHyperopiamedicine.anatomical_structureOptometryFemaleSurgerysense organsmedicine.symptombusinessJournal of Cataract and Refractive Surgery
researchProduct

Evaluation of the practicality of optical biometry and applanation ultrasound in 253 eyes

2003

Abstract Purpose To evaluate the percentage of eyes that could not be measured using optical biometry and ultrasound applanation and the reasons. Setting Department of Ophthalmology, Johannes Gutenberg-University Hospital, Mainz, Germany. Methods Optical biometry (IOLMaster®, Carl Zeiss Meditec AG) and A-scan ultrasound biometry were performed consecutively in 253 eyes scheduled for cataract surgery the next day. Lens opacities were evaluated with the Opacity Lensmeter (Interzeag), and a slitlamp examination and measurement of visual acuity were performed. The 2 techniques were compared in terms of the rate of and reasons for primary measurement failure. Results Measurement with the IOLMast…

AdultBiometryVisual acuityAdolescentLightPseudophakiagenetic structuresmedicine.medical_treatmentEye diseaseVision DisordersVisual AcuityIntraocular lensDiagnostic Techniques OphthalmologicalEyeRefraction OcularCataractOptical biometryLens Implantation IntraocularHumansMedicineChildAgedUltrasonographyAged 80 and overLenses Intraocularbusiness.industryUltrasoundMiddle AgedCataract surgerymedicine.diseaseeye diseasesSensory SystemsOptical axisOphthalmologyInterferometryChild PreschoolOptometrySurgerysense organsmedicine.symptombusinessPseudophakiaJournal of Cataract and Refractive Surgery
researchProduct

Contrast sensitivity after implantation of toric iris-claw lenses in phakic eyes.

2004

Abstract Purpose: To evaluate the change in contrast sensitivity after implantation of the Verisyse toric phakic intraocular lens (IOL) (AMO) for the correction of myopia with astigmatism. Setting: Department of Ophthalmology, Johannes Gutenberg-University, Mainz, Germany. Methods: Eighteen eyes had implantation of an iris-supported toric phakic IOL to correct myopia with astigmatism. The mean preoperative spherical equivalent was −12.65 diopters ± 3.6 (SD). The contrast sensitivity with best spectacle correction was determined before surgery and 3 months after surgery using the CSV-1000 HGT instrument (Vector Vision Inc.). Results: Three months after IOL implantation, the mean contrast sen…

Adultmedicine.medical_specialtygenetic structuresmedia_common.quotation_subjectAstigmatismPhakic intraocular lensProsthesis DesignCycles per degreelaw.inventionContrast SensitivityLens Implantation IntraocularlawOphthalmologyLens CrystallinemedicineMyopiaContrast (vision)HumansPhakic iolIris clawDioptremedia_commonLenses Intraocularbusiness.industryAstigmatismMiddle Agedmedicine.diseaseeye diseasesSensory SystemsLens (optics)OphthalmologySurgerysense organsbusinessJournal of cataract and refractive surgery
researchProduct