Mid-term results of zone 0 thoracic endovascular aneurysm repair after ascending aorta wrapping and supra-aortic debranching in high-risk patients

Objectives Surgical repair of aneurysmal disease involving the ascending aorta, aortic arch and eventually the descending aorta is generally associated with significant morbidity and mortality. A less invasive approach with the ascending wrapping technique (WT), supra-aortic vessel debranching (SADB) and thoracic endovascular aneurysm repair (TEVAR) in zone 0 was developed to reduce the associated risk in these patients. Methods During a 10-year period, consecutive patients treated by the ascending WT, SADB and TEVAR in zone 0 were included. All patients were considered at high risk for conventional surgery. Measured outcomes included perioperative deaths and morbidity, maximal aortic trans…

research product

Popliteal Artery Aneurysm Repair in the Endovascular Era: Fourteen-Years Single Center Experience

Abstract To compare outcomes of popliteal artery aneurysm (PAA) repair by endovascular treatment, great saphenous vein (GSV) bypass, and prosthetic bypass. Single center retrospective analysis of patients presenting PAA from 2000 to 2013. Patients were divided into endovascular treatment (group A); GSV bypass (group B); and prosthetic graft bypass (group C). Outcomes were technical success, perioperative mortality, and morbidity. Survival, primary and secondary patency, and freedom from reintervention rate were estimated. Differences in ankle-brachial index (ABI), in-hospital length of stay (InH-Los), red blood cell (RBC) transfusion, and limb loss were reported. Mean follow-up was 49 (medi…

research product

Mid- and Longer-term Follow up of Chimney and/or Periscope Grafts and Risk Factors for Failure

Objective The aim was to report on chimney and periscope grafts (CPGs) and their mid- and longer-term outcomes when they are used to preserve reno-visceral artery (RVA) perfusion in endovascular repair of pararenal (PRAAs) or thoraco-abdominal aortic aneurysm (TAAAs). In addition, factors associated with CPG failure are presented. Limited data exist on the outcomes of CPGs, and mid- and long-term results are generally not reported. Methods This was a prospective study in a cohort of 100 patients with PRAA (69) or TAAA (31). A total of 224 (mean 2.24 per patient) RVAs were preserved with 136 (61%) chimney and 88 (39%) periscope grafts. CPGs were constructed mainly using self expandable stent…

research product

Predilation technique with balloon angioplasty to facilitate percutaneous groin access of large size sheath through scar tissue

Purpose Percutaneous remote access for endovascular aortic repair is an advantageous alternative to open access. Previous surgery in the femoral region and the presence of synthetic vascular grafts in the femoral/iliac arteries represent major limitations to percutaneous remote access. The aim of this study was to evaluate an original technique used for enabling percutaneous remote access for thoracic or abdominal endovascular aortic repair in patients with scar tissue and/or a vascular graft in the groin. Methods Twenty-five consecutive patients with a thoracic (11/25; 44%) or an aortic aneurysm (14/25; 66%) and with a synthetic vascular graft in the groin (16/25; 64%) or a redo groin acce…

research product

A clampless and sutureless aortic anastomosis technique using an endograft connector for aortoiliac occlusive disease in which the aorta cannot be clamped or sewn due to calcification or scarring

Bypass surgery in aortoiliac or aortofemoral occlusive disease can be technically demanding and hazardous due to huge calcifications and/or patient co-morbidities. We report about mid-term results of a telescoping sutureless aortic anastomosis technique using endografts as connectors to address such challenging situations. This is a single-center experience (2004–2011) in seven patients (63 ± 6 years) requiring aortoiliac (three) or aortofemoral (four) bypass surgery. In six cases, an aortic stent graft was telescoped into the infrarenal aorta and partly deployed within the aorta and partly outside the aorta. In the first case, a bifurcated stent graft was deployed and the iliac legs were …

research product

The Gore Hybrid Vascular Graft in renovisceral debranching for complex aortic aneurysm repair.

Objective This study reports our initial experience with the Gore Hybrid Vascular Graft (GHVG; W. L. Gore & Associates, Flagstaff, Ariz) for staged hybrid open renovisceral debranching and endovascular aneurysm repair in patients affected by thoracoabdominal aortic aneurysms and pararenal abdominal aortic aneurysms (PAAAs). Methods Between December 2012 and December 2013, we analyzed outcomes of 13 patients who underwent open surgical debranching of renovisceral vessels for thoracoabdominal aortic aneurysm and PAAAs. All patients were considered at high risk for conventional surgery. Inclusion criterion was treatment by open surgical debranching of at least one visceral artery (renal artery…

research product

Outpatient endovascular aortic aneurysm repair: Experience in 100 consecutive patients

OBJECTIVES:: To present the safety, feasibility, costs, and patient satisfaction of outpatient endovascular aneurysm repair (EVAR). BACKGROUND:: Our experience in more than 1000 patients indicated that in technically uncomplicated EVAR procedures, the only need for hospitalization was for access vessel complications (bleeding or occlusion) requiring secondary procedures. These complications could always be identified within the first 3 hours after EVAR. METHODS:: Two-center retrospective analysis of prospectively gathered data on 100 consecutive elective outpatient EVAR cases (Outpt EVAR). Inclusion criteria for Outpt EVAR were as follows: asymptomatic clinical state, informed consent, trav…

research product

SS8. Chimney and Periscope Grafts: Mid-term Results in 77 Consecutive Patients with Complex Aortic Aneurysms

Author Disclosures: N. D. Andersen: Nothing to disclose; G. Hughes: W.L. Gore and Associates,Research Grants W.L. Gore and Associates, Consulting fees or other remuneration (payment) W.L. Gore and Associates, Speaker’s bureauMedtronic Vascular, Consulting fees or other remuneration (payment) Medtronic Vascular, Speaker’s bureauVascutek Terumo, Consulting fees or other remuneration (payment) Vascutek Terumo, Speaker’s bureau; R. L. McCann: Nothing to disclose; A. A. Shah: Nothing to disclose; J. B. Williams: Nothing to disclose.

research product

Acute aortic dissection

An acute aortic syndrome with simultaneous presence of a penetrating aortic ulcer, an intramural haematoma, a thoracic aortic dissection and an abdominal aortic aneurysm rupture has not previously been reported. Herein, we describe our experience with a patient treated by endovascular means with an 8-year follow-up.

research product

Long-term results of simplified frozen elephant trunk technique in complicated acute type A aortic dissection: A case-control study.

Aim To describe the long-term experience of a simplified frozen elephant trunk technique (sFETT) used in complicated acute type A aortic dissection (AAAD) treatment. Methods and results Between January 2001 and December 2012, 34 patients (mean age 59.9 ± 11.0 years) with complicated AAAD (DeBakey I) underwent an emergency surgery including sFETT. sFETT consisted in gluing the dissected aortic arch wall layers with gelatine-resorcinol adhesive and video-assisted antegrade open arch aortic stent-graft deployment in the arch or proximal descending aorta. In addition to sFETT, the aortic root was addressed with standard techniques. A 30-day mortality was 14.7% (five patients) due to bleeding (1…

research product

Endoluminal Stent-Graft Relining of Visceral Artery Bypass Grafts to Treat Perigraft Seroma

PURPOSE: To describe the endovascular treatment of intra-abdominal perigraft seromas associated with small-caliber expanded polytetrafluoroethylene (ePTFE) grafts. CASE REPORTS: Two patients who underwent hybrid repair of thoracoabdominal aortic aneurysms in which renovisceral bypass grafts were implanted presented with large, symptomatic perigraft seromas. The 5- to 8-mm-diameter ePTFE bypass grafts believed to be involved in the seromas were successfully relined with self-expanding Viabahn stent-grafts in percutaneous procedures. The patients' symptoms were relieved, and imaging follow-up (18 and 10 months, respectively) has shown near complete resorption of the seromas. CONCLUSION: It is…

research product

Chimney and periscope grafts observed over 2 years after their use to revascularize 169 renovisceral branches in 77 patients with complex aortic aneurysms

^ ^Purpose: To evaluate the performance of periscope and/or chimney grafts (CPGs) in theendovascular treatment of pararenal or thoracoabdominal aneurysms using off-the-shelfdevices.Methods: Between February 2002 and August 2012, 77 consecutive patients (62 men; meanage 7369 years) suffering from pararenal aortic (n¼55), thoracoabdominal (n¼16), or arch tovisceral artery aneurysms (n¼6) were treated with aortic stent-graft implantation requiringchimney and/or periscope grafts to maintain side branch perfusion. CPGs were planned inadvance and were not used as bailout. A standardized follow-up protocol includingcomputed tomographic angiography, laboratory testing, and clinical examination wasp…

research product

A New Off-Pump Hybrid Open and Endovascular Repair to Treat Ductus Botalli and Ascendens Aneurysms

To report a combined ascending aorta and aortic arch hybrid repair, we performed off-pump with no aortic graft replacement. A 65-year-old man, developing progressive recurrent laryngeal nerve paralysis, underwent a computed tomography (CT) angiography detecting nonpatent residual ductus Botalli aneurysm and ascending aorta aneurysm. Due to severe multimorbidities, a less-invasive alternative was elaborated. In a first step, appropriate proximal landing zone for aortic stent grafting was achieved by ascending aorta diameter reduction, with epiaortic wrapping, and debranching the supra-aortic trunks. In the second step, endovascular stent grafts were deployed from proximal ascending aorta to…

research product

Improved technique for sheath supported contralateral limb gate cannulation in endovascular abdominal aortic aneurysm repair

Summary: Background: To present a technique of sheath supported contralateral limb gate (CLG) cannulation of modular bifurcated stent-graft in endovascular abdominal aortic repair. Materials and methods: After totally percutaneous bilateral femoral access, the 9F introducer sheath is exchanged to a 30 cm 12 fr introducer sheath over a stiff wire contralateral to the intended main stent-graft insertion side and advanced into the aorta below the lowest renal artery. Parallel to the stiff wire within the sheath an additional standard J-tip guidewire with a 5 fr Pigtail angiographic catheter is advanced to the level of the renal arteries. After main body deployment, the 12 fr introducer sheath…

research product

Patient-Specific Rehearsal Feasibility Before Endovascular Repair of Ruptured Abdominal Aortic Aneurysm.

Purpose: To evaluate the feasibility of a patient-specific rehearsal (PsR) before emergency endovascular aneurysm repairs (eEVAR) and its influence on the operation. Materials and Methods: From February 2016 to October 2016, 10 consecutive patients (mean age 75 +/- 7.4 years; 9 men) presenting with a ruptured abdominal aortic aneurysm (rAAA) suitable for standard EVAR were enrolled in the study. A 3-dimensional (3D) model of the abdominal aorta was generated on a virtual reality simulator based on the patient's computed tomography (CT) images. Following the patient-specific simulation setup, PsR was conducted during patient admission or in parallel with the preoperative eEVAR workup. Measur…

research product

Identification of optimal device combinations for the chimney endovascular aneurysm repair technique within the PERICLES registry

Abstract Objective The ideal stent combination for chimney endovascular aneurysm repair remains undetermined. Therefore, we sought to identify optimal aortic and chimney stent combinations that are associated with the best outcomes by analyzing the worldwide collected experience in the PERformance of chImney technique for the treatment of Complex aortic pathoLogiES (PERICLES) registry. Methods The PERICLES registry was reviewed for patients with pararenal aortic disease electively treated from 2008 to 2014. Eleven different aortic devices were identified with three distinct subgroups: group A (n = 224), nitinol/polyester; group B (n = 105), stainless steel/polyester; and group C (n = 69), n…

research product

Less invasive (common) femoral artery aneurysm repair using endografts and limited dissection

Objective We report our experience with the treatment of femoral artery aneurysms (FAAs) under local anaesthesia with limited dissection, using endografts to facilitate the proximal anastomosis and some distal anastomoses. Method Between January 2006 and December 2010, six males, mean age 72 years (range, 65–80 years) with FAAs were treated at the University Hospital of Zurich. All operations were performed under local anaesthesia with analgosedation, except for one performed under spinal anaesthesia. After limited dissection and puncture of the anterior wall of the FAA, a sheath and a self-expanding endograft were introduced over a guide wire and with fluoroscopy they were guided intralumi…

research product

Classification of Chimney EVAR-Related Endoleaks: Insights from the PERICLES Registry

Juxtarenal aortic aneurysms (JAAs) pose significant challenges for endovascular aneurysm repair (EVAR). A short or absent infrarenal neck typically excludes standard EVAR as a viable or reasonable treatment option. In this context, the use of chimney grafts (chEVAR) is gaining in popularity and applicability. These grafts are designed to course in the aortic lumen outside the main stent-graft to maintain normal perfusion to the involved target branches. As such, they may represent a promising and less resource-intensive option for management of JAAs. However, this technical strategy is not without challenges of its own, particularly the inevitable creation of “gutters” that result from the …

research product

Incidence and prognostic factors related to major adverse cerebrovascular events in patients with complex aortic diseases treated by the chimney technique

Abstract Objective Endovascular aneurysm repair (EVAR) with the chimney technique (ch-EVAR) has been used for the treatment of aortic aneurysms as an alternative approach to fenestrated endografting or open repair. Nonetheless, the need for an upper extremity arterial access may contribute to a higher risk for periprocedural cerebrovascular events. This study reports on the perioperative cerebral and major adverse cardiac and cerebrovascular events (MACCE) after ch-EVAR. Methods The PERICLES registry (PERformance of the chImney technique for the treatment of Complex aortic pathoLogiES) is an international, retrospective multicenter study evaluating the performance of ch-EVAR for the treatme…

research product

Simultaneous Hybrid Treatment of Multilevel Peripheral Arterial Disease in Patients with Chronic Limb-Threatening Ischemia

Background: Hybrid treatments (HT) aim to reduce conventional open surgery invasiveness and address multilevel peripheral arterial disease (PAD). Herein, the simultaneous HT treatment in patients with chronic limb-threatening ischemia (CLTI) is reported. Methods: Retrospective analysis, for the period from May 2012 to April 2018, of patients presenting multilevel PAD with CLTI addressed with simultaneous HT. The outcomes of these interventions were measured the following metrics: early technical successes (within 30 days following treatment) and late technical successes (30 days or more following treatment) and included mortality, morbidity symptoms recurrence, and amputation. Survival and …

research product

A 12-Year Experience With Chimney and Periscope Grafts for Treatment of Type I Endoleaks.

Purpose: To evaluate the midterm outcomes of chimney and/or periscope grafts (CPGs) in patients presenting type I endoleak after a previous endovascular aneurysm repair (EVAR). Methods: Between June 2002 and April 2014, 24 consecutive patients (mean age 73.9±9.2 years; 23 men) presenting a type I endoleak were addressed with CPGs to extend the proximal and/or distal landing zone and to maintain side branch perfusion. Indication for treatment was a type Ia endoleak in 23 (96%) patients and a type Ib endoleak in one. Median interval from the previous EVAR to endoleak treatment with CPGs was 52.2±48.9 months (range 0.2–179). All patients had proximal/distal landing zones precluding any standa…

research product

Chronic Mesenteric Ischemia: Critical review and guidelines for management

Background CMI is caused by chronic occlusive disease of mesenteric arteries. In such an uncommon disease, clear recommendations are strongly needed. Unfortunately, treatment options for symptomatic CMI are still controversial and no guidelines exist. Methods A systematic literature review of the last 25-years was conducted through MEDLINE, Embase, and Cochrane Review/Trials register to identify studies reporting on CMI treatment with more than 10 patients. Primary outcomes were perioperative mortality and morbidity rates. Secondary outcomes were survival rates, primary and secondary patency rates, vessels treated, CMI recurrence, follow-up (FU), technical success (TS), and in-hospital leng…

research product

Hypotensive Hemostasis in Patients Presenting with Ruptured Aortic Aneurysm

Hypotensive hemostasis in aortic rupture has been showed to be feasible and advantageous, especially in trauma patients. To date, there are no randomized studies on hypotensive hemostasis in patients with ruptured abdominal aortic aneurysm (rAAA), but observational studies indicate similar advantages when hypotensive hemostasis is used for endovascular aneurysm repair (EVAR) as in trauma patients. Actually, in EVAR for rAAA, a target systolic blood pressure of 90 mmHg or even lower is considered safe in conscious patients. Fluids should be administrated judiciously with the sole aim of maintaining adequate cardiac output and tissue oxygenation, whereas vasoactive pressors or dilatators may …

research product

Endovascular Treatment of Spontaneous Internal Carotid Artery Dissection with Proximal Embolic Protection Device

Background The aim of this study was to report the feasibility and outcomes with the endovascular treatment of spontaneous internal carotid artery dissections (ICADs) using a proximal embolic protection device (EPD). Methods This is a retrospective analysis of patients treated for spontaneous symptomatic ICAD using a proximal EPD from January 2017 to December 2018. Indication for treatment was the presence of neurologic symptoms. Early outcomes measured included technical success, perioperative mortality, and major cardiovascular or cerebrovascular complications. Late outcomes were recurrent neurologic symptoms, patency, and reinterventions. Results A total of 4 male patients with ICAD were…

research product

Early outcomes with a single-sided access endovascular stent

Abstract Objective The objective of this study was to report the 1-year follow-up study results of the new Horizon stent graft (Endospan, Herzliya, Israel) from two different prospective consecutive trials. The Horizon abdominal aortic aneurysm stent graft system is a 14F profile system requiring only a single access site. It consists of three modules, introduced separately: base limb (iliac to iliac limb); distal aortic limb; and proximal aortic limb with a bare suprarenal crown and active fixation. Methods Data from the first in man (FIM) clinical study with 10 patients enrolled and the pivotal study with 30 patients were analyzed. Outcomes measured were freedom from major adverse events …

research product

CT Angiography at 24 Months Demonstrates Durability of EVAR With the Use of Chimney Grafts for Pararenal Aortic Pathologies

PURPOSE: To present the 24-month radiological follow-up data for patients with pararenal aortic pathologies treated with chimney and periscope grafts during endovascular repair. METHODS: Between January 2008 and December 2011, 124 high-risk patients with complex pararenal aortic pathologies were treated using the chimney technique at 2 European vascular and cardiovascular centers with advanced experience of the described technique. In particular, 50 patients were treated at Site 1 and 74 at Site 2. Forty (32.2%) patients (32 men; mean age 79.2±4.9 years) completed computed tomographic angiography follow-up at 24 months postoperatively. RESULTS: The overall technical success was 100%, and th…

research product

Chimney and periscope grafts to facilitate endovascular treatment of aortic transection in a patient with aberrant right subclavian artery

Purpose: To report the use of parallel grafts to extend the proximal landing zone for stentgraft repair of aortic transection involving an aberrant right subclavian artery (ARSA). Case Report: A 28-year-old patient was referred for treatment of traumatic aortic transection with contained rupture at the level of an ARSA. Immediate thoracic endovascular aortic repair (TEVAR) was planned because of hemodynamic instability. To achieve rapid sealing and maintain perfusion to both subclavian arteries, a chimney stent to the left subclavian artery (LSA) and a periscope stent-graft to the ARSA were deployed successfully. After surgical repair of all fractures, the patient was discharged 1 month aft…

research product

Periscope endograft technique to revascularize the left subclavian artery during thoracic endovascular aortic repair.

To present early and midterm results of the periscope endograft (PG) technique to maintain left subclavian artery (LSA) blood flow in thoracic endovascular aortic repairs (TEVAR) involving zone 3.From April 2010 to January 2013, 14 consecutive high-risk patients (11 men; mean age 70±8 years, range 56-87) underwent TEVAR with the PG technique for 10 thoracic aortic aneurysms (TAA), 2 traumatic aortic ruptures, and 2 aortic dissections without a suitable landing zone (2 cm distal to the LSA). Five procedures were performed emergently for rupture (3 TAAs and the 2 trauma cases). Two patients had a periscope deployed in an aberrant right subclavian artery. The periscope endografts were sized 1 …

research product

Treatment of isolated ascending aortic aneurysm by off-pump epiaortic wrapping is safe and durable.

OBJECTIVES: Isolated ascending aortic aneurysm (iAA) is usually treated by open graft repair requiring sternotomy, cardiopulmonary bypass (CPB) and cardioplegia. This approach carries significant mortality in older patients or those presenting with comorbidities. We report an original series of patients presenting with iAA and treated with epiaortic wrapping by using a synthetic mesh. This less invasive aortic repair technique allows reducing the aortic diameter to a predefined value and is performed without CPB. METHODS: Data from patients presenting with an iAA and treated with the wrapping technique (WT) by polypropylene/polyester mesh from November 2006 to July 2015 were collected. The …

research product

Mid-term Results of Chimney and Periscope Grafts in Supra-aortic Branches in High Risk Patients

Purpose Report mid-term outcomes of thoracic endovascular aneurysm repair (TEVAR) with chimney and periscope grafts (CPG) in supra-aortic branches (SAB). Methods Retrospective analysis, from October 2009 to May 2014, of patients with aneurysms requiring TEVAR with zone 0/1/2 proximal landing in association with at least one CPG in the SAB. All patients were considered at high risk for conventional surgery. Peri-operative mortality and morbidity, retrograde type A dissection, maximum aortic transverse diameter (TD) and its post-operative evolution, endoleak, survival, freedom from cardiovascular re-interventions, and CPG freedom from occlusion during the follow-up were analysed. Results Fort…

research product

Multiple periscope and chimney grafts to treat ruptured thoracoabdominal and pararenal aortic aneurysms

Purpose: To report midterm outcomes after urgent endovascular repair of ruptured pararenal or thoracoabdominal aortic aneurysms using multiple periscope and chimney grafts to preserve renovisceral branch perfusion and facilitate aneurysm exclusion. Methods: Nine consecutive men (mean age 72614 years, range 40–88) presenting with ruptured thoracoabdominal (n56), pararenal (n52), or infrarenal (n51) aortic aneurysm underwent urgent endovascular repair with at least 1 periscope graft delivered via a transfemoral access; chimney grafts were installed from an axillary access. In all, 17 periscope and 7 chimney grafts were used to reperfuse 11 renal and 13 visceral arteries in the 9 patients. The…

research product

The use of Endurant stent-graft for abdominal aortic aneurysm: the story about extension of instruction for use with persistent good results of stent-graft latest generation

The Endurant stent-graft (Medtronic, Inc., Minneapolis, MN, USA) is a latest generation device for the treatment of abdominal aortic aneurysm. The idea behind designing such a graft came from the intention to broad the instruction for use (IFU) and to enable it to treat more challenging anatomy including the 10mm neck lengths, and more severe suprarenal and infrarenal angulations. Endurant stent-graft has active fixation through suprarenal stent with anchoring pins to provide migration resistance, optimized heights of stents and spacing between them for improved flexibility and conformability, low-profile delivery system with hydrophilic coating and controlled simple deployment mechanism. S…

research product

Endovascular Treatment of Spontaneous and Isolated Infrarenal Acute Aortic Syndrome with Unibody Aortic Stent-Grafts

Abstract Introduction Spontaneous acute aortic syndrome (IAAS) is rarely localized in the infrarenal aorta. The endovascular approach is preferred over conventional open surgery with fewer complications. However, dedicated endovascular devices for IAAS treatment are unavailable. The aim was to report a large single-center experience using unibody stent-grafts to address IAAS. Methods From April 2016 to March 2019, a retrospective analysis of patients presenting spontaneous and isolated IAAS was performed. Patients addressed with the unibody stent-graft (AFX endovascular AAA system; Endologix Inc., Irvine, CA) were included in the study. Indications to IAAS treatment were persistent symptoms…

research product

Mortality rates and risk factors for emergent open repair of abdominal aortic aneurysms in the endovascular era

The background of this paper is to report the mortality at 30 and 90 days and at mean follow-up after open abdominal aortic aneurysms (AAA) emergent repair and to identify predictive risk factors for 30- and 90-day mortality. Between 1997 and 2002, 104 patients underwent emergent AAA open surgery. Symptomatic and ruptured AAAs were observed, respectively, in 21 and 79% of cases. Mean patient age was 70 (SD 9.2) years. Mean aneurysm maximal diameter was 7.4 (SD 1.6) cm. Primary endpoints were 30- and 90-day mortality. Significant mortality-related risk factor identification was the secondary endpoint. Open repair trend and its related perioperative mortality with a per-year analysis and a co…

research product

How to diagnose and treat abdominal compartment syndrome after endovascular and open repair of ruptured abdominal aortic aneurysms

Intra-abdominal hypertension (IAH) and abdominal compartment syndrome (ACS) are frequently encountered in patients treated for ruptured abdominal aortic aneurysms (rAAA) and carry a high morbidity and mortality risk. Despite these facts, IAH/ACS are still overlooked by many physicians, timely diagnosis is missed and treatment often inadequate. All staff involved in the treatment of rAAA should be aware of the risk factors predicting IAH/ACS, the profound implications and derangements on all organ systems, the clinical presentation, the appropriate measurement of intra-abdominal pressure to detect IAH/ACS and the current treatment options for these detrimental syndromes. This comprehensive r…

research product

RS12. Sustained Late Branch Patency and Low Incidence of Persistent Type Ia Endoleaks Following Snorkel/chimney EVAR Shown in the Updated PERICLES Registry

research product

Use of covered chimney stents for pararenal aortic pathologies is safe and feasible with excellent patency and low incidence of endoleaks.

Background To present the clinical experience of consecutive series with use of balloon-expandable and self-expanding chimney endografts (balloon-expandable covered stent group [BECS] vs self-expanding covered stent group [SECS]) in the endovascular treatment of challenging aortic pathologies requiring renal and/or visceral revascularization. Methods Between January 2009 and May 2011, data for 37 high-risk patients from one center and 35 patients from another institution, with pararenal aortic pathologies treated by the chimney endovascular technique, were prospectively collected. The chimney-graft technique is based on the deployment of a covered or bare-metal stent parallel to the aortic …

research product

Branch ligatures and blood aspiration for post-traumatic superficial temporal artery pseudoaneurysm: surgical technique

The aim of this study is to report a new minimally invasive technique of superficial temporal artery (STA) pseudoaneurysm treatment. Several surgical options have been employed to treat STA pseudoaneurysms. To address this rare condition, the employed techniques are ligation and excision of the aneurysm, endovascular coil embolization or percutaneous ultrasound-guided thrombin injection. Between techniques no significant differences are reported in terms of outcomes. The decision to adopt a technique depends on STA pseudoaneurysm morphology and surgeon preference. In the present report, STA pseudoaneurysm afferent and efferent branches were identified by ultrasound in a 92-year-old female. …

research product

Early endovascular aneurysm repair after percutaneous coronary interventions

Objective The objective of this study was to report long-term results of early endovascular aortic aneurysm repair after percutaneous coronary intervention (PCI). Methods This was a retrospective analysis of all patients presenting with abdominal aortic aneurysm and coronary artery disease treated during the same hospitalization by endovascular aortic aneurysm repair performed soon after PCI. Primary outcomes were perioperative mortality, perioperative complications, survival after treatment, and freedom from reintervention. Results A total of 20 patients were included, and all completed both procedures. No deaths or abdominal aortic aneurysm ruptures occurred between the PCI and the aortic…

research product

Single-centre experience and preliminary Results of intravascular ultrasound in endovascular aneurysm repair

Background Intravascular ultrasound (IVUS) has been introduced as diagnostic adjunct to provide new insights into the diagnosis and therapy of vascular disease. Herein, we compared the outcomes of conventional endovascular aneurysm repair (EVAR) and EVAR with IVUS in patients presenting with infrarenal abdominal aortic aneurysm using a propensity-matched cohort. Methods From May 2013 to August 2017, 221 patients were retrospectively analyzed. Of that, 122 patients were eligible for inclusion and underwent propensity score matching. Perioperative mortality and morbidity, renal function impairment, endoleak incidence, mean contrast medium usage, operative time, radiation exposure (including f…

research product