A PC-based wattmeter for accurate measurements in sinusoidal and distorted conditions: Setup and experimental characterization
This paper presents the development of a high-accuracy sampling wattmeter, which can be employed with both sinusoidal and distorted input signals. The proposed personal computer (PC)-based system is a simple, portable, and low-cost solution because it is based on two commercial data acquisition boards connected to a common PC. Owing to this solution, the voltage is sensed directly, avoiding expensive voltage dividers, while the current is sensed by means of a noninductive current shunt. Commercial software is also used for data processing and implementation of the virtual instrument. The setup of the PC-based wattmeter is described, with a detailed description of the correction strategy of …
An harmonic test condition for the metrological characterization and the operating principle identification of reactive static meters
This paper faces the problem of the metrological characterization of the static meters for reactive energy in the presence of harmonic distortion. Starting from the only available accuracy test condition in the presence of harmonics introduced in the Standards for active static meters, an experimental approach is proposed for the verification of such meters in the presence of harmonic distortion, as well as for the individuation of their operating principle. A theoretical validation of the obtained results is presented by means of a comparison with a standard and a commercial static meter with a known operating principle.
Un approccio sperimentale per la caratterizzazione dei contatori statici di energia reattiva in presenza di distorsione armonica
Electrical distribution substation remote diagnosis and control system
This paper presents the conception, design, set up and realization of a prototype system for telemanagement of a MV/LV substation. The prototype has been developed according to the current standards. This system allows to monitor the status of the MV/LV substation box, of the medium voltage equipment, of the transformer and of the low voltage equipment. In particular, the system acts when some specified events occur. The prototype has been realized by using a DAQ; the software that implement the telemanagement system has been developed in LabVIEW environment. The system allows a remote monitoring of the quantities of interest that is carried out using the TeamViewer software able to establi…
Development of a high-accuracy PC-based wattmeter with commercial data acquisition boards
This paper presents the development of a high accuracy sampling wattmeter, which makes use of two commercial data acquisition boards (DAQs) connected to a common personal computer. Commercial software is also used for data processing and implementation of the virtual instrument. The set up of the PC-based wattmeter is described and a preliminary evaluation of its metrological performances is made by means of two series of experimental tests, which were carried out with an electric power standard and a high performance multifunction calibrator. © 2011 IEEE.
STUDIO E SVILUPPO DI NUOVE STRATEGIE PER LA REALIZZAZIONE DI CAMPIONI DI POTENZA ED ENERGIA SIA IN REGIME SINUSOIDALE CHE IN PRESENZA DI DISTORSIONE ARMONICA
Metrological characterization and operating principle identification of static meters for reactive energy: an experimental approach under nonsinusoidal test conditions
In this paper, an experimental approach is proposed for the metrological characterization of the static meters for reactive energy and for the individuation of their operating principle in nonsinusoidal conditions. The proposed approach was developed by starting from the only available accuracy test condition in the presence of the harmonics introduced by the standards for active static meters. In this paper, the proposed approach is described, and some experimental tests are presented, which were performed on some meters of different accuracy classes and with both known and unknown operating principles.
DAQs-based wattmeters for high accuracy measurements. Comparison with the Italian power primary standard
Abstract This paper is focused on the use of data acquisition boards (DAQs) for the development of high accuracy PC-based instruments for the measurements of electrical power. The proposed systems are simple, portable and low cost because they are based on commercial data acquisition boards (DAQs) connected to a common personal computer. Data processing is carried out by a commercial software based on an interpolating windowed FFT. In the paper it is shown how the voltage can be sensed directly, thanks to the DAQ input range, thus avoiding expensive voltage dividers. The set up of the DAQs-based solutions is described and the evaluation of their metrological features is made by means of a c…
Riferibilità dei contatori statici di energia reattiva in presenza di armoniche. Evoluzione normativa e prove sperimentali
A PC-based wattmeter for high accuracy power measurements
This paper proposes the use of a commercial data acquisition board (DAQ) connected to a common personal computer for high accuracy power measurements. In the paper the set up of the PC-based wattmeter is described and an experimental evaluation of its metrological performances is made by means of the comparison with a simultaneous coherent digital sampling wattmeter realized with two high-precision DMMs Hewlett Packard Model 3458 A. In both cases the power source is a Fluke 6100A/E electrical power standard. © 2010 IEEE.
Un wattmetro basato su schede di acquisizione commerciali per misure in regime distorto. Sviluppo dello strumento e prove preliminari
La verifica dei contatori statici di energia reattiva in presenza di armoniche. Problematiche di misura e possibili soluzioni
A DAQ-based sampling wattmeter for IEEE Std. 1459-2010 powers measurements. Uncertainty evaluation in nonsinusoidal conditions
Abstract This paper presents the evaluation of the metrological performances of a DAQ-based sampling wattmeter (DAQ-SW) for the measurement of IEEE Std. 1459-2010 power quantities in non-sinusoidal conditions. The instrument makes use of two commercial data acquisition (DAQ) boards, a non-inductive current shunt, a personal computer and a commercial software for data processing. Starting from the results of an experimental characterization of the two instrument channels with non-sinusoidal voltages and currents and a correlation analysis, the combined standard uncertainties of IEEE Std. 1459-2010 quantities are evaluated, following the approach of the ISO Guide to the Expression of Uncertai…
Caratterizzazione del campo di induzione magnetica prodotto da cabine secondarie
L’articolo presenta una metodologia per la caratterizzazione del campo di induzione magnetica nei pressi di cabine secondarie di tipo a box prefabbricato in cemento armato vibrato, che costituisce un valido strumento per la verifica del rispetto degli obiettivi di qualità imposti dalla legislazione vigente.
Problematiche di misura per la caratterizzazione dei contatori statici di energia reattiva in condizioni non sinusoidali
Traceability of static reactive energy meters in the presence of harmonics: theoretical considerations and a DAQ-based reference meter
This paper deals with some problems related to the measurements traceability with static meters for reactive energy. These problems arise when the meters operate in the presence of harmonics, which can negatively affect their performances, depending on implemented metric. The paper analyzes the problem in the light of both in-force and draft standards, from the viewpoint of the performances of both commercial meters and reference standard instruments. The analysis is supported by some experimental tests, which are carried out by means of a reference meter, based on data acquisition boards, which can be used in both sinusoidal and distorted conditions.
Critical issues and future prospects of the secondary substation in smart grid context
This paper is focused on the new role of the secondary substation in the smart grids context. This innovative view has been proposed and developed in the framework of two Research Projects: NewCabELARC Project and Reipersei Project. The latter provides a concrete and comprehensive low cost solutions for the smart grid monitoring and control, allowing the real diffusion and integration of Distributed Generation and the full exploitation of Renewable Energy Sources. In this field, this paper shows how the secondary substation (SS) takes the role of smart transducer node where innovative devices can be located, collecting the measurement data coming from the field devices (power and energy met…
Active-fixation coronary sinus pacing lead extraction: A hybrid approach
Cardiac resynchronization therapy (CRT) can be considered as the standard treatment for patients suffering from heart failure (NYHA III–IV), severely reduced left ventricular (LV) function, and wide QRS complexes. Over the past years, the lead systems used to stimulate the left ventricle have evolved technically from epicardial approaches to a transvenous access accompanied by a significant reduction of procedure-related complication rates [1]. However, even today, LV dislodgement rates ranging 5–10% and the instability of thresholds over time remain the greatest challenges with transvenous LV leads in CRT. Therefore, a special LV lead utilizing active fixation (the Attain StarFix® active f…
Jugular pacing lead extraction with laser sheath: a case report.
Over the past 20 years, the number of patients with pacemakers (PM) or implantable cardioverter defibrillators has risen markedly; consequently, an increasing number of lead-removal procedures have become necessary. A 64-year-old woman presenting with an infected device pocket and positive bacterial cultures ( Staphylococcus aureus ) was admitted to our department for lead removal; in 1991, she underwent VVI PM implantation for atrioventricular II degree Mobitz 1 block, and a unipolar lead was introduced via the left jugular vein. The procedure was performed in our Electrophysiology Lab with a cardiac surgeon on standby, using an excimer laser system emitting the energy at the tip of a flex…
Psychodiagnostic Assessment of Pathological Gamblers: A Focus on Personality Disorders, Clinical Syndromes and Alexithymia
Comorbid psychopathological syndromes are common in pathological gamblers (PGs), but the contribution of alexithymia, as a disorder of affect regulation, has not been fully explored yet. This study sought to examine the association between personality disorders, clinical syndromes and alexithymia levels in a group of PGs and to highlight a relationship between gambling behaviour and alexithymia scores, apart from the relationship between other disorders and gambling behaviour. Psychological assessment included the South Oaks Gambling Screen, Millon Clinical Multiaxial Inventory (MCMI-III) and Toronto Alexithymia Scale (TAS-20) performed on 70 treatment seeking PGs and 70 healthy controls. S…