0000000000025110

AUTHOR

T. Grossmann

Interdisciplinary experiments with polarized 3He

Abstract Optical pumping of metastable 3 He atoms is a very efficient method to produce large quantities of nuclear spin-polarized 3 He. Recent developments in mechanical compression of the gas, its storage and transport allow for its flexible use in different fields of physics and applied science. Among these are (1) scattering experiments of polarized beams from polarized 3 He-targets, (2) 3 He as neutron spin filter to polarize neutron beams at research reactors, and (3) polarized 3 He gas inhaled into the lungs to perform magnetic resonance imaging. The paper discusses the different topics along with results obtained in a first round of experiments.

research product

Nuclear magnetic resonance imaging of airways in humans with use of hyperpolarized3He

The nuclear spin polarization of noble gases can be enhanced strongly by laser optical pumping followed by electron-nuclear polarization transfer. Direct optical pumping of metastable 3He atoms has been shown to produce enormous polarization on the order of 0.4-0.6. This is about 105 times larger than the polarization of water protons at thermal equilibrium used in conventional MRI. We demonstrate that hyperpolarized 3 He gas can be applied to nuclear magnetic resonance imaging of organs with air-filled spaces in humans. In vivo 3 He MR experiments were performed in a whole-body MR scanner with a superconducting magnet ramped down to 0.8 T. Anatomical details of the upper respiratory tract …

research product

3He-MRI-based measurements of intrapulmonarypO2 and its time course during apnea in healthy volunteers: first results, reproducibility, and technical limitations

We applied a recently developed method of following the time course of the intrapulmonary oxygen partial pressure p(O2)(t) during apnea by (3)He MRI to healthy volunteers. Using two imaging series with different interscan times during two breathholds (double acquisition technique), relaxation of (3)He due to paramagnetic oxygen and depolarization by RF pulses were discriminated. In all four subjects, the temporal evolution of p(O2) was found to be linear, and was described by an initial partial pressure p(0) and a decrease rate R. Also, regional differences of both p(0) and R were observed. A correlation between p(0) and R was apparent. Finally, we discuss limitations of the double acquisit…

research product

Volumetry of Ventilated Airspaces by 3He MRI

To develop a validated post-processing routine for volumetry of the ventilated airspaces by 3He MRI.3Helium MRI and pulmonary function tests were performed in seven healthy volunteers. After segmentation of ventilated airspaces, their volumes were calculated. Functional residual capacity (FRC) was used as a reference. For comparison of absolute volumes, correction factors were evaluated.Mean lung volume (+/- standard deviation) calculated from 3He MRI was 4,082 +/- 908 mL and mean FRC was 3,696 +/- 1166 mL, with a mean difference of 386 mL (r = 0.88). After correction for the relative pulmonary air content (factor 0.82), posture (0.72), and the individual tidal volume, 3He MRI volume was 3,…

research product

Helium-3-MRT der Lungenventilation: Erste klinische Anwendungen

PURPOSE: of the study is the visualisation of normal pulmonary ventilation in healthy volunteers and the evaluation of abnormalities in patients with different lung diseases using 3He magnetic resonance imaging (3He-MRI). MATERIAL AND METHODS: Hyperpolarized 3He gas (V = 300 ml, p = 3 x 10(5) Pa, polarised to 35-45% by optical pumping, provided in special glass cells) was inhaled by eight healthy volunteers and ten patients with different lung diseases. A 3D FLASH sequence (TR = 11.8 ms; TE = 5 ms; matrix 144 x 256, FOV 350 mm, section thickness 7-10 mm, coronal orientation) was performed in a single breath-hold (22-42 s). Clinical and radiological examinations were available for correlatio…

research product

Realization of a broad band neutron spin filter with compressed, polarized 3He gas

The strongly spin dependent absorption of neutrons in nuclear spin polarized 3He opens the possibility to polarize beams of thermal and epithermal neutrons. An effective 3He neutron spin filter (NSF) requires high 3He nuclear polarization as well as a filter thickness corresponding to a gas amount of the order of 1 barl. We realized such a filter using direct optical pumping of metastable 3He∗ atoms in a 3He plasma at 1 mbar. Metastable exchange scattering transfers the angular momentum to the whole ensemble of 3He atoms. At present 3 × 1018 3He-atoms/s are polarized up to 64%. Subsequent polarization preserving compression by a two stage compressor system enables to prepare NSF cells of ab…

research product

Ultraschnelle MRT der Lungenventilation mittels hochpolarisiertem Helium-3*

Objective Assessment of the temporal and spatial dynamics of hyperpolarized Helium-3 (3He) distribution in the lung with ultrafast gradient-echo magnetic-resonance imaging. Material and methods Coronal images of the lung were acquired using ultrafast gradient-echo pulse sequences with TR/TE = 3.3 ms/1.3 ms (slice thickness, 40 mm) and TR/TE = 2.0 ms/0.7 ms (without slice selection). A series of 80 or 160 projection images was obtained with 210 ms or 130 ms temporal resolution, respectively. Imaging was performed during several respiratory cycles after application of a single bolus of 300 mL hyperpolarized 3He. Measurements were performed in six healthy volunteers (spontaneous breathing). Re…

research product

Realization of a broad-band neutron spin filter with compressed, polarized 3He gas

The strongly spin-dependent absorption of neutrons in nuclear spin polarized 3He opens the possibility to polarize beams of thermal and epithermal neutrons. An effective 3He neutron spin filter (NSF) requires high 3He nuclear polarization as well as a filter thickness corresponding to amount of gas in the order of 1 bar 1. We realized such a filter using direct optical pumping of metastable 3He∗ atoms in a 3He plasma at 1 mb. Metastable exchange scattering transfers the angular momentum to the whole ensemble of 3He atoms. At present 3.6 × 1018 3He-atoms s−1 are polarized up to 68%. Subsequent polarization preserving compression by a two-stage compressor system enables to prepare NSF cells o…

research product

Nuclear magnetic resonance imaging with hyperpolarised helium-3

Abstract Summary Background Magnetic resonance imaging (MRI) relies on magnetisation of hydrogen nuclei (protons) of water molecules in tissue as source of the signal. This technique has been valuable for studying tissues that contain significant amounts of water, but biological settings with low proton content, notably the lungs, are difficult to image. We report use of spin-polarised helium-3 for lung MRI. Methods A volunteer inhaled hyperpolarised 3 He to fill the lungs, which were imaged with a conventional MRI detector assembly. The nuclear spin polarisation of helium, and other noble gases, can be greatly enhanced by laser optical pumping and is about 10 5 times larger than the polari…

research product

3He MRI in healthy volunteers: preliminary correlation with smoking history and lung volumes

MRI with hyperpolarized helium-3 (3He) provides high-resolution imaging of ventilated airspaces. The first aim of this 3He-study was to compare observations of localized signal defects in healthy smokers and non-smokers. A second aim was to describe relationships between parameters of lung function, volume of inspired 3He and signal-to-noise ratio. With Ethics Committee approval and informed consent, 12 healthy volunteers (seven smokers and five non-smokers) were studied. Imaging was performed in a 1.5 T scanner using a two-dimensional FLASH sequence at 30V transmitter amplitude (TR/TE/α = 11 ms/4.2 ms/<10°). Known amounts of 3He were inhaled from a microprocessor-controlled delivery device…

research product

Analysis of intrapulmonary O2concentration by MR imaging of inhaled hyperpolarized helium-3

Inhalation of hyperpolarized 3He allows magnetic resonance imaging (MRI) of ventilated airspaces.3He hyperpolarization decays more rapidly when interacting with paramagnetic O2. We describe a method for in vivo determination of intrapulmonary O2 concentrations ([O2]) based on MRI analysis of the fate of measured amounts of inhaled hyperpolarized3He in imaged regions of the lung. Anesthetized pigs underwent controlled normoventilation in a 1.5-T MRI unit. The inspired O2 fraction was varied to achieve different end-tidal [O2] fractions ([Formula: see text]). With the use of a specifically designed applicator,3He (100 ml, 35–45% polarized) was administered at a predefined time within single …

research product