0000000000027898
AUTHOR
Faramarz Wahdat
On the inverse-voltammetric determination of zinc in acidic solution
Zur Bestimmung kleiner Zinkmengen in salzsauren Losungen ist die inverse Wechselspannungsvoltammetrie geeignet. Besonderheiten des Einflusses der Elektrolysezeit und kleinerer Kupfergehalte werden beschrieben. Die Standardabweichung der Einzelbestimmung mit 50 ng Zn/ml betrug ± 1,6%.
Invers-voltammetrische Bestimmung einiger Schwermetalle in Bier durch Kombination eines UV-Aufschlusses mit Durchflu�zelle
The inverse-voltammetric determination of the natural contents of lead and copper in beer is possible in a flow-through cell with medium exchange after UV-photolysis. The working conditions are given and the results are compared with those obtained by a wet oxidative digestion procedure. The relative standard deviations were: Cu 3.5% and Pb 1.4%.
Inverse-voltammetric determination of cadmium, lead and copper in animal samples after solubilization
The conditions for the inverse-voltammetric determination of cadmium, lead, and copper in various biological samples after solubilization with Texapon are described. The results of this procedure are compared with those obtained with conventional high- and low-pressure wet digestions. The advantages of the Hg-film electrode as compared to the stationary Hg-electrode are discussed.
Adsorptionsvoltammetrische Bestimmung des Cobalts und Nickels an Quecksilberfilmelektroden und in Durchflußzellen
Die adsorptionsvoltammetrische Bestimmung des Cobalts und Nickels an einer mit einem Hg-Film uberzogenen Glascarbonelektrode und in Durchfluszellen wurde untersucht. Absolute Mengen von 0,1 ng Co und 0,5 ng Ni konnen in einer derartigen Zelle mit groser Analysengeschwindigkeit bestimmt werden (22–25 s pro Bestimmung).
Digestion-free determination of heavy metals (Pb, Cd, Cu) in honey using anodic stripping differential pulse voltammetry and potentiometric stripping analysis
Experiments have been carried out to assess the potential of differential pulse voltammetry and potential stripping analysis for determining Pb, Cu and Cd directly in dissolved honey samples using a flow-through cell. With the hanging mercury drop electrode Pb alone can be determined only if the electrode is first modified in-situ with Triton X 100 to increase the separation between the Pb peak and a broad, interfering adsorption peak which overlaps the Cu peak. If the (more sensitive) thin film mercury electrode is used the interference encountered is less so also Cu and Cd can be determined. With potentiometric stripping analysis Cu and Pb can be determined using normal procedures. The de…
Direct inverse voltammetric determination of Pb, Cu and Cd in some edible oils after solubilization
The direct determination of traces of certain heavy metals in oils is possible after treatment of the methanolic sample solution with Lumatom (tetramethylammoniumhydroxide). For the inverse voltammetric determination, a flow through cell with a mercury film electrode is used. The results for the determination of Cu and Pb in some edible oils after solubilization agree well with those obtained using wet oxidative high pressure ashing.
Die aufschlußfreie Bestimmung von Schwermetallen (Zn, Cd, Pb, Cu) in Getränken (Wein) durch inverse Voltammetrie in einer Durchflußzelle
Digestion-free determination of trace-metals (Zn, Cd, Pb, Cu) in beverages by inverse voltammetry in a flow-through cell equipped with a mercury film-electrode is described. Optimal enrichment potentials are obtained by inspection of the pseudopolarograms of the elements in the original diluted sample solution. After the deposition step in the untreated sample solution stripping is effected in a proper supporting electrolyte after medium exchange. Values obtained by this techniques with various samples compare well with those obtained by usual procedures including wet digestion of the samples.
Selective and sensitive determination of copper by stripping voltammetry after medium exchange in a flow-through cell
La methode permet de doser le cuivre a des teneurs de 5 a 20 μg/l en presence d'autres elements
Einfluß von Nitroverbindungen und von Tensiden auf die inversvoltammetrische Bestimmung von Cadmium, Blei und Kupfer. Vergleich inverse Differentielle Pulsepolarographie und inverse Chronopotentiometrie („Potentiometric Stripping Analysis“)
Der Einflus grenzflachenaktiver Substanzen und organischer Nitroverbindungen allein und in Kombination auf die inverse chronopotentiometrische Analyse (PSA) des Cd, Pb und Cu wird untersucht. In einigen Fallen bietet die Bestimmung mittels PSA Vorteile bei der Bestimmung dieser Elemente in Anwesenheit organischer Nitroverbindungen im Vergleich zur inversen differentiellen Pulse-Polarographie.
Einfluß von Temperatur und Lösungsmittelzusätzen auf die adsorptionsvoltammetrische Bestimmung des Nickels neben Cobalt
Zusatze von Alkoholen und tiefere Arbeitstemperaturen verbessern die Bestimmungsmoglichkeiten des Ni neben Co durch Adsorptionsvoltammetrie in triethanolhaltigen Grundlosungen mit Dimethylglyoxim. Optimale Bedingungen zur Bestimmung des Ni neben einem 50–100fachen Co-Uberschus sind Zusatz von 50% Methanol und Arbeiten bei −10° C. Mit Losungen von 5 ppb Ni wurden relative Standardabweichungen von 2,1% erhalten.
Zur invers-voltammetrischen Bestimmung des Cadmiums in Aerosolen
Zur invers-voltammetrischen Bestimmung kleiner Cadmiumgehalte in Aerosolsammel-proben wird die Abtrennung des Cadmiums durch Verdampfung im Wasserstoffstrom bei hoherer Temperatur nach vorausgehender Oxydation der Probe im Sauerstoffstrom vorgeschlagen. In 125 cm2 Filterprobe konnen noch 0,15–0,25 μg Cd mit Sicherheit bestimmt werden. Einzelheiten und Ergebnisse des Verfahrens werden mitgeteilt.
Inverse- Voltammetric determination of cadmium
Die invers-voltammetrische Bestimmung des Cadmiums in inerten Mineralsauren mit und ohne Losungswechsel wird untersucht und der Einflus anderer Elemente (Pb, In, Tl, Sn, Sb, Bi, Cu) auf die Bestimmung festgestellt.