0000000000041365

AUTHOR

Zahir Salhi

showing 14 related works from this author

Magnetized boxes for housing polarized spins in homogeneous fields

2010

Abstract We present novel types of permanently magnetized as well as current powered boxes built from soft-ferromagnetic materials. They provide shielded magnetic fields which are homogeneous within a large fraction of the enclosed volume, thus minimizing size, weight, and costs. For the permanently magnetized solutions, homogenization is achieved either by an optimized distribution of the permanent field sources or by jacketing the field with a soft-ferromagnetic cylindrical shell which is magnetized in parallel to the enclosed field. The latter principle may be applied up to fields of about 0.1 T. With fields of about 1 mT, such boxes are being used for shipping spin-polarized 3 He worldw…

PhysicsNuclear and High Energy PhysicsCondensed matter physicsSpinsBiophysicsMechanicsModels TheoreticalCondensed Matter PhysicsBiochemistryHomogenization (chemistry)Magnetic fieldlaw.inventionMagneticsElectromagnetic FieldsHomogeneouslawShielded cableComputer SimulationSpin LabelsJournal of Magnetic Resonance
researchProduct

Flip-angle measurement by magnetization inversion: Calibration of magnetization nutation angle in hyperpolarized 3 He magnetic resonance imaging lung…

2010

The aim of this work was to establish a new, fast, and robust method of flip-angle calibration for magnetic resonance imaging of hyperpolarized 3He. The method called flip-angle measurement with magnetization inversion is based on acquiring images from periodically inverted longitudinal magnetization created using the spatial modulation of magnetization technique. By measuring the width of the area where the magnetization was inverted by the spatial modulation of magnetization preparation in phase images, the flip angle can be generated using a simple equation. To validate and establish the limits of the proposed method, flip-angle measurement with magnetization inversion acquisitions were …

medicine.diagnostic_testChemistrybusiness.industryNutationInverse transform samplingMagnetic resonance imagingImage processingMagnetizationNuclear magnetic resonanceOpticsFlip anglemedicineRadiology Nuclear Medicine and imagingWaferbusinessExcitationMagnetic Resonance in Medicine
researchProduct

Pushing the Limit – MRI of the Lung Using Hyperpolarized 3-Helium in Conjunction with Parallel Imaging

2009

Imaging of the lung with hyperpolarized 3He became a well known technique in the last decade. Being able to image ventilation and the microstructure of the lung an increase of SNR and a shortage of scan time is eligible. By using a 32-channel phased array the sensitivity was increased dramatically. High resolution 2D-images with a resolution of 1 × 1 mm2 having a 3 mm slice was realized, showing highly detailed images of the lung. By applying parallel imaging techniques the SNR could be increased and scan time was reduced drastically by using a 2D acceleration of R = 4 × 2 with a 3D-protocol covering the whole lung.

LungMaterials sciencePhased arrayResolution (electron density)chemistry.chemical_elementHigh resolutionScan timeAccelerationmedicine.anatomical_structureNuclear magnetic resonancechemistrymedicineParallel imagingHelium
researchProduct

Realization of administration unit for3He with gas recycling

2011

Hyperpolarized (HP) noble gases (3He,129Xe) are used for MR-imaging of the lung. In the majority of case the HP gas is filled in Tedlarbags and directly inhaled by the patients. Starting from an earlier pilot device, an administration unit was built respectively to the Medical Devices Law to administer patients HP noble gas boli in defined quantities and at a predefined time during inspiration with high reproducibility and reliability without reducing MR-quality. The patient's airflows are monitored and recorded. It is possible to use gas admixtures, measure the polarization on-line and collect the exhaled gas for later recycling. The first images with healthy volunteers were taken with thi…

Clinical studyHistoryReproducibilitybusiness.industryHealthy volunteersNoble gasMedicinebusinessComputer Science ApplicationsEducationBiomedical engineeringJournal of Physics: Conference Series
researchProduct

Measurement of gas transport kinetics in high-frequency oscillatory ventilation (HFOV) of the lung using hyperpolarized 3He magnetic resonance imaging

2010

PURPOSE: To protect the patient with acute respiratory distress syndrome from ventilator associated lung injury (VALI) high-frequency oscillatory ventilation (HFOV) is used. Clinical experience has proven that HFOV is an efficient therapy when conventional artificial ventilation is insufficient. However, the optimal settings of HFOV parameters, eg, tidal volumes, pressure amplitudes and frequency for maximal lung protection, and efficient gas exchange are not established unambiguously. METHODS: In this work magnetic resonance imaging (MRI) with hyperpolarized (3)He was employed to visualize the redistribution of gas within the cadaver pig lung during HFOV. The saturated slice method was use…

Artificial ventilationARDSMaterials scienceVentilator-associated lung injurySwinemedicine.medical_treatmentKineticsHigh-Frequency VentilationHeliumOscillometryPressuremedicineAnimalsRadiology Nuclear Medicine and imagingLungRespiratory Distress SyndromeLungmedicine.diagnostic_testHigh-frequency ventilationApneaMagnetic resonance imagingModels Theoreticalmedicine.diseaseMagnetic Resonance ImagingRespiration ArtificialKineticsmedicine.anatomical_structureAnesthesiaGasesmedicine.symptomBiomedical engineeringJournal of Magnetic Resonance Imaging
researchProduct

A polarized 3He target for the photon beam at MAMI

2011

Abstract A polarized 3 He target has been installed for the first time inside the 4 π Crystal Ball detector at the tagged photon beam of the MAinz MIcrotron (MAMI). It has been demonstrated that the system works reliably and that the polarization losses during handling of the polarized gas are under control. Initial polarization values up to 70% and total relaxation times up to 20 h could be obtained during a first test beam time devoted to the measurement of the double polarized photoabsorption cross-section in the Δ ( 1232 ) baryon resonance region.

PhysicsNuclear and High Energy Physics010308 nuclear & particles physicsDetectorPolarization (waves)01 natural sciencesParticle detectorDelta baryonNuclear physicsBaryonHelium-30103 physical sciencesPhysics::Accelerator Physics[PHYS.PHYS.PHYS-INS-DET]Physics [physics]/Physics [physics]/Instrumentation and Detectors [physics.ins-det]Atomic physics010306 general physicsNuclear ExperimentInstrumentationMicrotronCrystal Ball
researchProduct

Design and evaluation of a 32-channel phased-array coil for lung imaging with hyperpolarized 3-helium

2010

Imaging with hyperpolarized 3-helium is becoming an increasingly important technique for MRI diagnostics of the lung but is hampered by long breath holds (>20 sec), which are not always applicable in patients with severe lung disease like chronic obstructive pulmonary disease (COPD) or α-1-anti-trypsin deficiency. Additionally, oxygen-induced depolarization decay during the long breath holds complicates interpretation of functional data such as apparent diffusion coefficients. To address these issues, we describe and validate a 1.5-T, 32-channel array coil for accelerated 3He lung imaging and demonstrate its ability to speed up imaging 3He. A signal-to-noise ratio increase of up to a factor…

COPDLungChannel (digital image)Image qualitybusiness.industrymedicine.diseasePhased array coilmedicine.anatomical_structureNuclear magnetic resonanceLung imagingArray coilmedicineRadiology Nuclear Medicine and imagingbusinessImage resolutionMagnetic Resonance in Medicine
researchProduct

Recycling of 3He from lung magnetic resonance imaging

2011

We have developed the means to recycle 3He exhaled by patients after imaging the lungs using magnetic resonance of hyperpolarized 3He. The exhaled gas is collected in a helium leak proof bag and further compressed into a steel bottle. The collected gas contains about 1–2% of 3He, depending on the amount administered and the number of breaths collected to wash out the 3He gas from the lungs. 3He is separated from the exhaled air using zeolite molecular sieve adsorbent at 77 K followed by a cold head at 8 K. Residual gaseous impurities are finally absorbed by a commercial nonevaporative getter. The recycled 3He gas features high purity, which is required for repolarization by metastability ex…

Leakbusiness.product_categoryContrast Mediachemistry.chemical_elementMolecular sieveHeliumAdsorptionIsotopesGetterImpurityAdministration InhalationBottlemedicineHumansRecyclingRadiology Nuclear Medicine and imagingLungHeliumChromatographymedicine.diagnostic_testChemistryMagnetic resonance imagingEquipment DesignMagnetic Resonance ImagingEquipment Failure AnalysisExhalationRadiopharmaceuticalsbusinessMagnetic Resonance in Medicine
researchProduct

Application unit for the administration of contrast gases for pulmonary magnetic resonance imaging: optimization of ventilation distribution for3He-M…

2014

Purpose MRI of lung airspaces using gases with MR-active nuclei (3He, 129Xe, and 19F) is an important area of research in pulmonary imaging. The volume-controlled administration of gas mixtures is important for obtaining quantitative information from MR images. State-of-the-art gas administration using plastic bags (PBs) does not allow for a precise determination of both the volume and timing of a 3He bolus. Methods A novel application unit (AU) was built according to the requirements of the German medical devices law. Integrated spirometers enable the monitoring of the inhaled gas flow. The device is particularly suited for hyperpolarized (HP) gases (e.g., storage and administration with m…

ReproducibilityMaterials sciencemedicine.diagnostic_testMagnetic resonance imaginglaw.inventionPulmonary imagingVolume (thermodynamics)lawAnesthesiaHealthy volunteersVentilation (architecture)medicineRadiology Nuclear Medicine and imagingHyperpolarization (physics)Mr imagesBiomedical engineeringMagnetic Resonance in Medicine
researchProduct

POLARIZED 3HE TARGETS FOR REAL AND VIRTUAL PHOTONS

2011

PhysicsOpticsbusiness.industryVirtual particlebusinessPolarized targetPolarized Sources, Targets and Polarimetry
researchProduct

Polarized3He targets in medium energy physics at MAMI

2011

Experiments with polarized 3He targets at the Mainz Microtron (MAMI) involve double polarized photoabsorption or the extraction of the electric form factor of the neutron Ge,n via electron scattering, respectively. Polarized 3He with an initial polarization of up to 70% at the experimental areas is provided by a polarizer based on the principle of metastability exchange optical pumping (MEOP). In this article both target setups for the photon- and the electron beamlines will be described and a status of the data analysis will be given.

PhysicsHistoryPhotonElectric form factorElectronPolarizerPolarization (waves)Computer Science ApplicationsEducationlaw.inventionNuclear physicsOptical pumpinglawNeutronNuclear ExperimentMicrotronJournal of Physics: Conference Series
researchProduct

Three-dimensional mapping of the B 1 field using an optimized phase-based method: Application to hyperpolarized 3 He in lungs

2010

A novel method is presented for the three-dimensional mapping of the B1-field of a transmit radio-frequency MR coil. The method is based on the acquisition of phase images, where the effective flip angle is encoded in the phase of the nonselective hard pulse excitation. The method involves the application of a rectangular composite pulse as excitation in a three-dimensional gradient recall echo to produce measurable phase angle variation. However, such a pulse may significantly increase the radio-frequency power deposition in excess of the standard acceptable SAR limits, imposing extremely long TRs (>100 msec), which would result in acquisition times significantly greater than a single brea…

Materials sciencePulse (signal processing)business.industryPhase anglePhase (waves)Pulse sequenceImaging phantomNuclear magnetic resonanceOpticsFlip angleRadiology Nuclear Medicine and imagingSensitivity (control systems)businessExcitationMagnetic Resonance in Medicine
researchProduct

A highly polarized target for the electron beam at MAMI

2009

Abstract Polarized He 3 from metastability exchange optical pumping (MEOP) is used as an effective polarized neutron target for electron scattering experiments at the MAinz MIcrotron (MAMI). With the present setup an initial polarization of up to 72% has been obtained at the experimental area. A novel calibration technique will be presented which allows the determination of the absolute polarization within a relative uncertainty of 3%.

PhysicsNuclear and High Energy Physicsbusiness.industryPolarization (waves)Polarized targetOptical pumpingNuclear physicsOpticsMetastabilityCathode rayNeutronNuclear ExperimentbusinessInstrumentationMicrotronElectron scatteringNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
researchProduct

Yttria-stabilized zirconia in-flight particle characteristics under vacuum plasma spray conditions

2009

This paper deals with the diagnostic yttria-stabilized zirconia (YSZ) in-flight particles in Vacuum Plasma Spray (VPS) process using an optical measurement device. Particle velocity, temperature and diameter were correlated to spray distance under a fixed chamber pressure of about 14 kPa. Experiments were carried out with a two-color pyrometer. Results show that correlations can be satisfactory described with linear relationships. Particle velocity and temperature decrease when increasing spray distance whereas particle diameter exhibits a linear increase with the spray distance.

Spray characteristicsMaterials sciencePhysics::Instrumentation and DetectorsAnalytical chemistryCondensed Matter PhysicsSurfaces Coatings and Filmslaw.inventionChamber pressureSpray nozzlelawParticleParticle velocityThermal sprayingInstrumentationYttria-stabilized zirconiaPyrometerVacuum
researchProduct