0000000000048351
AUTHOR
S. Köhler
Die experimentelle Bestimmung der Ionisationsenergien von Berkelium und Californium
Resonance ionization mass spectroscopy for trace analysis of neptunium
Resonance ionization mass spectroscopic (RIMS) measurements for trace analysis and spectroscopy of 237Np, the ecologically most important isotope of neptunium, are described. The chemical procedure for the separation of neptunium from aqueous samples as well as the preparation of filaments for RIMS are outlined. Several two- and three-step excitation schemes have been investigated in order to find suitable conditions for the sensitive detection of 237Np. Using a three-step, three-color excitation and ionization scheme an overall detection efficiency of 3×10−8 was obtained, resulting in a detection limit of 4×108 atoms (160 fg) of 237Np. The hyperfine structure splittings of the levels under…
First Experimental Determination of the Ionization Potentials of Berkelium and Californium
Erste Messung der Ionisationsenergie von Americium und Curium
Quantitative Detection of Strontium-90 and Strontium-89 in Environmental Samples by Laser Mass Spectrometry
Parallel to the strongly growing public concern about environmental problems, new ideas for trace detection and analysis of toxic and radioactive material are being developed. One of these new and outstanding experimental techniques is the application of analytical laser spectroscopy. Most interesting in this context is the method of resonance ionization spectroscopy (RIS), as proposed1 already in 1972 combining very high sensitivity in the detection of the element or isotope under investigation with high selectivity in the suppression of contaminants2–4.
Resonance ionization mass spectroscopy for trace determination of plutonium in environmental samples
Resonance ionization mass spectroscopy (RIMS) is a sensitive and isotope selective method and well suited for trace analysis of plutonium in the environment. After the chemical isolation of plutonium from soil, air filters or urine, e.g., it is electrolytically deposited as hydroxide on a tantalum backing and covered with a thin titanium layer. By heating such a sandwich filament in the RIMS-apparatus under vacuum an atomic beam of plutonium is produced. The atoms are ionized by a three-step resonant excitation using pulsed dye lasers, and the ions are mass-selectively detected with a time-of-flight (TOF) spectrometer and a multi channel plate detector. RIMS yields a low detection limit of …
Determination of the first ionization potential of actinide elements by resonance ionization mass spectroscopy
Abstract Resonance ionization mass spectroscopy (RIMS) in the presence of an external static electric field has been used for the determination of photoionization thresholds. Extrapolation of the thresholds obtained with different electric field strengths to zero field strength directly leads to the first ionization potential (IP). The ionization potentials of the transplutonium elements americium, curium, berkelium and californium could be measured for the first time. Due to the high sensitivity of RIMS, samples of only 1012 atoms have been used. The results are: IPAm = 5.9738(2)eV, IPCm = 5.9915(2)eV, IPBk = 6.1979(2)eV and IPCf = 6.2817(2)eV. The same technique was applied to thorium, ne…
First Determination of the Ionization Potential of Americium and Curium
Peripherally Circulating CD4+ FOXP3+ CXCR3+ T Regulatory Cells Correlate with Renal Allograft Function
Peripheral immunoregulation depends on T regulatory cell trafficking into the allograft to modulate the local alloresponse. Little is known about the relevance of trafficking receptors for Tregs after solid organ transplantation in humans. In this study, expression of the peripheral chemokine receptors CXCR3 and CCR5 on CD4+ FOXP3+ Treg cells was analysed and correlated with allograft function in renal transplant recipients. Flow cytometry analysis of peripheral blood mononuclear cells of 54 renal transplant recipients receiving a calcineurin inhibitor-based immunosuppression was performed for CD4, CD25, FOXP3, CXCR3 and CCR5 within the first 18 months post-transplantation. Correlation anal…
Determination of the first ionization potential of nine actinide elements by resonance ionization mass spectroscopy (RIMS)
The high sensitivity of RIMS enables the precise determination of the first ionization potential of actinide elements with a sample size of ≤1012 atoms. By multiple resonant laser excitation, the actinide atoms under investigation are ionized in the presence of an electric field, and the ions are mass-selectively detected in a time-of-flight spectrometer. The first ionization potential is obtained by scanning the wavelength of the laser used for the last excitation step across the ionization threshold Wth—indicated by a sudden increase of the ion count rate—at various electric field strengths. Extrapolation of Wth to electric field strength zero leads directly to the first ionization potent…